background image

SIGNAGE

DESIGNATION

ART. NO.

YEAR+WEEK

1004355

XXXXXXX

XXXXXXXXXXXXX

TYPE

XXXXXXXXXX

TEMPERATURE

XXXXXXXXXXX

XXXX

LOAD

XXXXX

PROD. ORDER

XXXXXXX

XXXXXX

XX/XX

Hz

PROJECT/SERIAL NO.

XXX

XXXXXXX

W

XXXX

A

VAC

ASSA ABLOY Entrance Systems AB LODJURSGATAN 10 LANDSKRONA SWEDEN

FACTORY NO. X

xxxxxxx

xxxxxxx

1002

SÜD

1

2

3

4

5

6

7

8

CLASSIFICATION  DIN 18650

No entry

Keep clear

No entry

B

A

C

1200

Keep clear

D

1100

Automatic 

door

Automatic 

door

F

as

sa

abl
oy

ent

ran
ce.

com

E

If problem

occurs

Action

Check that all required signage is applied and intact. Mandatory indicates that the signage is re-
quired by European directives and equivalent national legislation outside the European Union.

Product label: Mandatory

A

No entry, identifying one-way traffic: Mandatory in GB and US, if applicable, not included
in the product.

B

Supervision of child (applied to both sides of the door): Mandatory according to national
regulations. Recommended, if the risk analysis shows use by children.

C

Keep clear

D

ASSA ABLOY Entrance Systems door sticker: Mandatory, if applicable to highlight the
presence of the glass (applied to all glass sections that are moving).

E

Automatic door

F

Contact your ASSA ABLOY Entrance Systems service representative. For contact information, see last page.

=

15

Issue 2020-10-09

1014896-en-7.0

Содержание RD150-3

Страница 1: ...Original instructions User Manual Entrance Systems Revolving Door ASSA ABLOY RD150 3 RD150 4 assaabloyentrance com...

Страница 2: ...ain parts 9 ON OFF switch 9 Start up 9 ON 9 OFF 9 Reset 10 Safety 10 Safety device on the door 11 Pressure sensitive safety edges 11 Force sensitive door leaves 12 Emergency stop button 13 Regular saf...

Страница 3: ...rance Systems 23 Declaration of conformity ASSA ABLOY as word and logo are trademarks owned by the ASSA ABLOY Group ASSA ABLOY Entrance Systems 2020 Technical data subject to change without notice Bac...

Страница 4: ...ars of age if they have been instructed by a person in charge of their safety The operator can be used by children 8 years of age or younger if they are supervised by a person respons ible for their s...

Страница 5: ...and on the user is encouraged to try to correct the interference by one or more of the following measures Re orient the receiving antenna Relocate the receiver with respect to the equipment Move the r...

Страница 6: ...fects or delays in deliveries by sub contractors caused by any such cir cumstances Please note Non compliance with manufacturers care and maintenance recommendations may void the warranty ASSA ABLOY E...

Страница 7: ...Sweden Address ASSA ABLOY RD150 3 and ASSA ABLOY RD150 4 Type 100 240 V AC 10 15 50 60 Hz Mains power supply 360W including LED spot lights max 30W Power consumption 20 to 50 C Temperature range IP20...

Страница 8: ...LED with control option 3 ON OFF switch 4 Emergency stop button 5 Horizontal pressure sensitive safety edges on the door leaves option 6 Vertical pressure sensitive safety edges on the door leaves op...

Страница 9: ...oor is activated by the inner or outer activation unit or by pushing Push and Go the door rotates at normal speed through three compartments and then stops OFF Check there is no traffic Turn the ON OF...

Страница 10: ...RGENCY STOP C D Standard Description No Pressure sensitive safety edges placed on the drum edges see page 11 1 Force sensitive door leaves see page 11 2 Emergency stop button see page 12 3 Options Des...

Страница 11: ...e obstacle is removed the rotation continues Force sensitive door leaves The door makes three attempts to start with two seconds pause between each attempt If the obstacle is cleared and the door push...

Страница 12: ...ped by pressing the emergency stop button E M ERGENCY STOP To reset the door to normal operation release the emergency stop button by rotating it in the direction of the arrows and press reset button...

Страница 13: ...ally for condition of door seals and weather stripping 1 condition of glazing rubbers 2 3 Check the safety sensors if any If you are unsure of which type of sensor you have please contact your ASSA AB...

Страница 14: ...e The cleaning should be documented To avoid damages to the profiles the brushes must be vacuum cleaned weekly Do not expose windows doors or profiles to alkalis Both aluminium and glass are sensitive...

Страница 15: ...act Mandatory indicates that the signage is re quired by European directives and equivalent national legislation outside the European Union Product label Mandatory A No entry identifying one way traff...

Страница 16: ...uilding Check that nothing is jammed beneath the door The motor starts but door will not rotate Unlock the mechanical locks Check that nothing is jammed beneath the door The door does not close Check...

Страница 17: ...ws the recommended interval in revolutions when to replace parts during preventive maintenance Talk to your ASSA ABLOY Entrance Systems representative to learn more about our service offering Minimum...

Страница 18: ...cal ASSA ABLOY Entrance Systems company for detailed description Lighting LED with control ILL 01650 Colour temp 3000 K Lamp 5W Additional emergency stop button In case of an emergency door rotation c...

Страница 19: ...uces speed to 0 5 rpm configurable When the obstacle is removed the rotation starts Laser presence sensing system Installedonthetopofthedoorleaves providessafetyoverthewholeheightofthedoor Ifthesensor...

Страница 20: ...he door stops When the obstacle is removed the rotation starts Mechanical lock Lock the door leaf Turn the ON OFF switch to OFF Use the key to lock the door leaf Unlock the door leaf Use the key to un...

Страница 21: ...afety zone approx 25 from the drum edge the door stops When the obstacle is removed the rotation starts Accessories Direction sensing radar DSR The radar DSR is direction sensing i e it triggers an op...

Страница 22: ...doors Dock shelters Air curtains Folding doors Sliding doors High speed doors Swing doors Loadhouses Automatic and manual activation units Overhead sectional doors Service such as preventive maintena...

Страница 23: ...r standards or technical specifications which have been applied EN 1627 2011 Class RC3 IEC 60335 2 103 ed 2 1 2011 IEC 60335 1 ed 5 2010 Certificate issued by a notified or competent body for full add...

Страница 24: ...lbanyandMegadoor brands we offer our solutions under the ASSA ABLOY brand Our products and services are dedicated to satisfying end user needs for safe secure convenient and sustainable operations ASS...

Отзывы: