Passport 1000 Series P1 PoE Mortise Lock  

Installation Wiring 

Overview

5

General Description

2

Hardware Specifications

3

• 

Inside lever retracts latch

• 

Locks furnished for 1-3/4” doors only

• 

Grade 1; UL Listed

•  Outside lever controlled by any combination of 

keypad, magnetic keypad, iCLASS, prox (prox-

imity) reader, or mechanical cylinder 

• 

Complete locksets with on-board memory

• 

Magnetic swipe standard with optional 125 kHz 
Proximity Reader (specify PRX-), 13.56 MHz 
reader (specify IKM-), and/or keypad (specify KP-)

• 

ADA Compliant

• 

Easily retrofits existing Passport 1000 door preps 
(cylindrical locks)

• 

Latch  1/2” standard

              3/4” throw fire-rated double doors 
              (optional) (41- prefix)
• 

Guarded latch

• 

Outside lever is unlocked through access  
control credentials only

Electronic Specifications

4

• 

2,400 users per lock; 10,000 event audit trail

• 

Multiple time zone and holiday access scheduling

• 

Centralized lock management 

• 

Real time door status monitoring

• 

First-In unlock configuration, either by time or by 
user (selectable)

• 

Lock down capable

• 

Input Power: PoE Class 2 Device, as defined  
by IEEE 802.3af, requires up to 7 watts  
over structured cabling

• 

Uses existing Magstripe keycards (track 2)

• 

Magnetic Stripe Card Coercivity: HiCo (4000 Oersted) or 
LoCo (300 Oersted)

•  Supports HID 125 kHz prox or 13.56 MHz iCLASS 

credentials (26 - 39 bit); supports CSN reads for other 

common 13.56 MHz cards, including MiFare, DesFire, and 

Felica

The SARGENT Passport Series v.P1 cylindrical lock is available with either an HID

®

 Prox 125 kHz or 13.56 MHz 

iCLASS

®

 technology reader. It utilizes existing infrastructure and IEEE 802.3af PoE (Power over Ethernet)  providing 

access control with Magnetic swipe and optional Proximity Reader and/or Keypad, as well as detailed audit capabilities-
technology as a proven alternative to traditional access control installations. The  v.P1 is a self-contained microproces-
sor-controlled access control product with non-volatile memory. It uses the existing network cable to communicate with 
access control systems. The v.P1 lock holds a total of 2400 different user codes. 
Using PoE technology coupled with third party software, this v.P1 online lock offers a complete, integrated  
access control system.
The Passport Series v.P1 cylindrical lock may be used for both indoor and outdoor applications. A weather- 
protective gasket is recommended for outdoor applications. 

HID and iCLASS are registered trademarks of HID Global Corporation.

*  Lockdown and real-time door  
   status monitoring available 
   only when lock is hard-powered 

SARGENT Passport Series PoE 
v.P1 Typical Application

LMT: Lock Management Tool

A. PoE frame harness assembly
B. PoE data hinge from McKinney  

    (patent pending)
C. PoE door harness* from McKinney
D. DPS: Door Position Switch 

    (Cylindrical and Exits only)
E. Passport Series v.P1 PoE Lock
    * Door width determines length

Network Cable

Network Switch (802.3af)

Surface Mount RJ45

 

A

B

C

D

E

Supplied by Others

PRELIMINARY

Содержание P1-IKM

Страница 1: ...Voice 770 831 8048 Fax 770 831 8598 Certification Exhibit FCC ID U4A SCYICLS2 IC 6982A SCYICLS2 FCC Rule Part 15 225 IC Radio Standards Specification RSS 210 ACS Report Number 11 0071 W06 11 A Manufacturer Assa Abloy Inc Model P1 IM IKM Manual ...

Страница 2: ...Company an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited PASSPORT1000 Mortise Lock Installation Instructions P1 P R E L I M I N A R Y ...

Страница 3: ...nce when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct ...

Страница 4: ...ersted Supports HID 125 kHz prox or 13 56 MHz iCLASS credentials 26 39 bit supports CSN reads for other common 13 56 MHz cards including MiFare DesFire and Felica The SARGENT Passport Series v P1 cylindrical lock is available with either an HID Prox 125 kHz or 13 56 MHz iCLASS technology reader It utilizes existing infrastructure and IEEE 802 3af PoE Power over Ethernet providing access control wi...

Страница 5: ...harness D Passport 1000 Online P1 PoE Lock Order of installation may vary Refer to appropriate sections for instructions Frame Side Harness Assembly 15 length 24AWG Stranded Drain Wire for Earth Ground in 15 Frame Harness Cable drain wire concealed in shrink tubing Patch Panel Drain Wire Terminated on Rack Cable CAT 5e or higher 24 AWG shielded with drain wire RJ45 F Jack Approved Software Certifi...

Страница 6: ...ference only eg 10BaseT Ethernet uses pairs 2 3 The pin numbers indicate actual physical locations on the plug and jack Frame Side Harness Assembly 15 length 24AWG Stranded Drain Wire for Earth Ground in 15 Frame Harness Cable drain wire concealed in shrink tubing A Frame Harness Installation 1 Feed cut end of harness into hole on hinge side through single access hole 2 Push one connector back thr...

Страница 7: ...und wire Lock side harness connectors Ring terminal 2 4 pin connectors 4 pin Molex connector 4 pin connector Notes Connectors go on only one way They cannot be plugged to incorrect position Do not force and do not offset connectors Be sure they are completely seated flush Order of installation may vary Refer to appropriate sections for instructions Hinge side harness connectors 4 pin male Molex co...

Страница 8: ... 10 12 13 14 Outside ITEM No PART No DESCRIPTION 1 52 0757 Lens Cliplite 2 52 0738 Outside Passport Escutcheon Only Magnetic Swipe and Keypad 52 0739 Outside Passport Escutcheon Only Magnetic Swipe 3 52 0760 Light Pipe Cliplite 4 52 3593 Slim Style Keypad Assembly 5 01 9299 4 40 x 3 16 Phillips Pan Head Screw 6 52 3591 Swipe Reader Assembly 7 52 0745 Online Interface PCB 8 52 3209 Harness Assembly...

Страница 9: ... DESCRIPTION 1 52 1103 Outside Passport Escutcheon only Magnetic Swipe Keypad and Proximity Reader 2 52 3593 Slim Style Keypad Assembly 3 01 9299 4 40 x 3 16 Phillips Pan Head Screw 4 52 4243 Swipe Reader Assembly 5 52 1106 Prox Reader Gasket 6 52 4206 Antenna Assembly 7 52 0745 Online Interface PCB 8 52 3209 Harness Assembly 9 52 1109 Back Plate 10 52 0748 Inside Mounting Plate 11 77 0168 8 32 x ...

Страница 10: ...1 PoE Mortise Lock Parts Breakdown 8 1 2 3 4 5 10 4 4 4 9 8 7 6 Magnetic Card Swipe With 13 56 MHz iCLASS and Keypad 4 ITEM No PART No DESCRIPTION 1 52 4402 Outside Mask Assembly 2 52 1255 Outside Escutcheon iCLASS 3 52 3593 Slim Style Keypad Assembly 4 01 9299 4 40 x 3 16 Machine Screw 5 52 4243 Swipe Reader Assembly 6 52 4401 iCLASS Module Assembly 7 52 3209 Harness Assembly 8 52 4410 iCLASS Har...

Страница 11: ...nder Rosette 4 See catalog Mortise Lockbody 5 77 2592 130 KB Thumbturn for Deadbolt Functions Only 6 See catalog Inside Lever Handle 7 See catalog Outside Lever Assembly 8 82 0368 Spindle 9 82 3088 Inside Lever Knob Adapter Plate Assembly 10 01 1495 8 32 X 5 8 Machine Screw 11 82 0612 Non Loosening Wave Washer 12 See catalog Mortise Rose 13 82 0347 Spindle Spring 14 01 1019 12 24 X 1 2 Machine Scr...

Страница 12: ... x Rose Lever x Finish x Hand KP P1 PRX or IKM 82277 x Rose Lever x Finish x Hand KP P1 PRX or IKM 82278 x Rose Lever x Finish x Hand KP P1 PRX or IKM 82279 x Rose Lever x Finish x Hand Note KP is for the optional Keypad and PRX is for the optional Proximity Reader IKM P1 PRX 10G77 x Rose lever x Finish x Hand Note IKM is for the 13 56 MHz Reader option B Verify Product Label C Door Preperation Fi...

Страница 13: ...lockbody Inside of Door Plastic Retaining Ring Connector Ring Terminal Slot B Retaining Ring Make sure the plastic retaining ring is seated cor rectly Fig 2B 1 The wires and the plastic retaining ring must be located on the non cylinder side 2 Orient the plastic retaining ring so that the word Bottom is located at the bottom of the cylinder hole 3 Route the wires from the top of the cylinder hole ...

Страница 14: ...s first followed by the lock body Feed wire into mortise slot 2 12 x 1 1 4 Long Flat Head Wood Screw for Wood Doors 2 12 24 x 1 2 Long Flat Head Machine Screw for Metal Doors Fig 3A PoE Cables Fig 3B Mortise Lock Body Connector and Ground Ring Terminal 4 Install Cylinder 1 Slide cylinder through the spring and ro sette collar and screw into lockbody rotat ing the cylinder clockwise Cylinder should...

Страница 15: ...w Note Thumb turn should cover screw head when deadbolt is retracted Refer to instructions A5675G included in package included with lock 1 Slide the outside lever and spindle assembly through the door and lockbody 2 Using the inside adapter plate and spindle secure loosely with 2 8 32 screws Note Position threaded hole on the inside adapter to align with lever hole 3 Tighten the lockbody screws on...

Страница 16: ... 8B 4 Attach 2 ground ring terminals one from controller and one from lock body to bottom right corner using one 8 32 x 1 7 8 flat head machine screw Make sure they are positioned upright Fig 8A 5 Insert other three 8 32 x 1 7 8 flat head machine screws and tighten fastening the outside escutcheon to the door Fig 8B IMPORTANT If the following step is skipped the product will not be UL compliant 6 ...

Страница 17: ...abs attached securely Outside of Door Fig 9A Tabs Detail 10B 2 4 Pin PoE connectors e d b c 24 pin from reader 10 pin from lock body e d c b 10 Attach Connectors Secure the following connectors onto the circuit board Fig 10A and 10B 1 Secure the 10 pin lock body assembly connector e 2 Secure the 24 pin keypad card reader connector d 3 Secure two 4 pin PoE connectors b and c 4 Secure the iCLASS rea...

Страница 18: ... P1 PoE Mortise Lock 11 Install Inside Escutcheon 1 Position inside escutcheon as shown Fig 11A Verify that all wires are positioned within the escutcheon to avoid pinching 2 Attach escutcheon with 2 8 32 x 1 2 T 20 Torx pan head screws 3 Straighten escutcheon and tighten securely DO NOT OVERTIGHTEN Fig 11A 2 8 32 x 1 2 Torx Screws Attach front plate with 2 8 32 X 1 4 flat head screws Fig 12A 12 A...

Страница 19: ...cylinder and wiring harness to eliminate issues b The key should retract the latch and the key should rotate freely c The key should extend and retract the deadbolt For units without a keypad add card using LCT software and test For units with a keypad add pin and card using LCT software and test 2 LED signalling After using a valid credential a green flash followed by three fast amber flashes ind...

Страница 20: ...lacement applications The company s customer base includes commercial construction institutional and industrial markets Copyright 2010 Sargent Manufacturing Company an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited ASSA ABLOY is the global leader in door opening solutions dedicated ...