Assa Abloy Norton UniTrol UNI-1600BC Series Скачать руководство пользователя страница 4

Copyright © 2016 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved. 
Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited. 

80-9316-2533-020 Rev 1

4

ASSA ABLOY

Increase

Decrease

Closing Speed Control           

 

Attention: Adjust Closing Speed 
Time to between 4 to 7 seconds 
from 90°. Use of the door by 
handicapped, elderly or small 
children may require greater 
closing time. ADA code requires 
that door take at least 3 
seconds to close from 70° of 
door opening to within 3” 
(75mm) of the closed position.

Closing Cycle

CLOSED

E

E

W

P

S

H

C

T

A

L

10°

Figure 1

CAUTION:

DO NOT BACK VALVES OUT OF 

CLOSER OR A LEAK WILL 

RESULT

CAUTION:

DO NOT BACK VALVES OUT OF 

CLOSER OR A LEAK WILL 

RESULT

Opening Door Control          

Opening Cycle

G

N

I

N

E

P

O

•  Backcheck (”BC”) valve controls the hydraulic resistance to door opening in backcheck range. 

NEVER close this valve completely – it is not to provide a positive stop.

BACKCHECK

Figure 2

Unit Adjustment

• Valve “S” controls Sweep Range.
• Valve “L” controls Latch Range.

NOTE: By law the Americans with Disabilities Act (ADA) may 
require that door closer installation comply with accessability 
guidelines.

"L"Valve

"S"Valve

1/8”
Hex
Key

Slow

Fast

1/8”
Hex
Key

Increase

Decrease

"BC" Valve

4

Closing Power Control          

Figure 3

1/8”
Hex
Key

Increase

Decrease

Bracket Illustrations

Door Holder Option

Figure 4

Standard 6190 Bracket

Deep Reveal Option

Spacer Block

Clamps

2 Clamp Screws

No. 6191 Reinforcing Kit

No. 2022 Bracket

Flush Partition Option

4 Bracket
Screws

Hold-Open

 option is found at the arm elbow. To select 

hold-open “on” or hold-open “off” and to adjust the hold-
open force ... use screwdriver as illustrated.

Turn 90°

To “Off”

Press & Turn

To Decrease

Force

To Increase

Force

Hold-Open

“On”

Hold-Open Force

Cover (Optional Cover 1600P)

Thread in screws before mounting closer. Leave enough gap 
between the head of the screw and the closer to slide the 
cover on. Slide the cover over the closer and secure the 
mounting screws after installation is complete.

4=1604BC

3=1603BC

To identify your model:

1- 6=1601

Date

Code

1-6

BE

Size

Code

Power Adjustment Chart

DOOR

PARALLEL ARM

INSTALLATION

MAXIMUM DOOR SIZE

34”

(0.85 m)

36”

(0.9 m)

40”

(1 m)

44”

(1.1 m)

48”

(1.2 m)

*30 -360° TURNS MAXIMUM AVAILABLE

*

FULL 360

TURNS

OF PO

WER  

ADJUSTMENT

SHAFT

1601

3

5

5

8

8

11

11

16

14

19

INT

EXT

Adjust as required. Product is shipped at 
approximately 8 turns of spring adjust.

3000 Highway 74 East  •  Monroe, NC 28112

Tel: (800)-438-1951 ext. 6030

www.nor tondoorcontrols.com