1

6

ASSA ABLOY

Closing Power Adjustment–

Using “Power Adjustment Chart” from Page 3, select the 
correct number of turns for power adjustment shaft that 
corresponds with the installation. With 1/8” hex-key provided, 
rotate adjustment shaft full 360° clockwise turns to desired 
setting. After closer has been installed and proper 
adjustments made to the sweep and latch, it may be 
necessary to readjust spring power for good closing action.

Control Valve Adjustments

(See Figure 2.)

Closing Speed Controls (Figure 1and 2.)
 

Valve “S” Controls Sweep Range.

 

Valve “L” Controls Latch Range.

 

Unit Adjustment

Opening Cycle

 “Backcheck” valve controls the strength of cushioning in 
Backcheck Range (approximately 70° to maximum swing). 
NEVER close this valve completely – it is not to provide a 
positive stop. (see Figure 4 and Figure 5).

H

C

T

A

 

L

Closing Speed Controls                                         Figure 1.

WEEP

S

 

Attention : Adjust Closing Speed Time 
to between 4 to 7 seconds from 90°. 
Use of the door by handicapped, 
elderly or small children may require 
greater closing time.

CLOSED

Standard Closing Cycle

10°

CAUTION:

DO NOT BACK VALVES OUT OF

CLOSER OR A LEAK WILL

RESULT.

Closing Speed Controls                                         Figure 2.

Closing Power Control                                           Figure 3.

Increase

Decrease

CAUTION:

DO NOT BACK VALVES OUT OF 

CLOSER OR A LEAK WILL 

RESULT

"L"Valve

"S"Valve

1/8”
Hex
Key

Slow

Fast

1/8”
Hex
Key

Increase

Decrease

See “Power Adjustment Chart” Page 3

G

N

I

N

E

P

O

 

Opening Door Control                                            Figure 4.

 Opening Cycle

BACKCH

ECK

CAUTION:

DO NOT BACK VALVES OUT OF

CLOSER OR A LEAK WILL

RESULT.

Backcheck Control                                                 Figure 5.

NEVER CLOSE BC VALVE 

COMPLETELY - NOT 

INTENDED TO PROVIDE 

A POSITIVE STOP.

1/8”
Hex
Key

Increase

Decrease

"BC" Valve

4

Model Identification                                                Figure 6.

To identify your model:

Date

Code

1-6

BE

Size

Code

1 - 6 = 1601
3 = 1603BC
4 = 1604BC

3000 Highway 74 East  •  Monroe, NC 28112

Tel: (800)-438-1951 ext. 6030

www.nor tondoorcontrols.com

suppor [email protected]