•  For special applications, a separate door and frame 

preparation template is packed with these instructions. Use 

this instruction sheet for installation sequence and closer 

adjustments only. 

•  Doors should be hung on ball bearing or anti-friction hinges. 

•  Door and frame must be properly reinforced.

Mounting Hardware

Door or Frame

Drill

Closer:  

1/4-14 x 1-1/2 Oval Flat Head Mach. Screw

Wood

3/16" (4.76mm)

Closer: 

 

1/4-20 x 3/4 Oval Flat Head Mach. Screw

Metal

Drill #7 (.201 dia. or 5.10mm) 

Tap 1/4-20

Arm Foot: 

Sleeve Nut and Bolt (SNB)

Hollow Metal

9/32" (7.00mm) thru 

3/8" (9.50mm) door face opposite to closer

Aluminum or Wood 3/8" (9.50mm) thru

Arm Foot: 

Thru Bolt and Grommet Nut (TBGN) 

(optional)

All

9/32" (7.00mm) thru 

3/8" (9.50mm) dia. x 3/8" (9.500mm) deep, 

door face opposite to closer

•  Always consult door/frame manufacturer for fastener 

compatibility.

•  Adjust closing time speed between 4 and 7 seconds from 

90° to 0°. Use of door by handicapped, elderly or small 

children may require greater closing time.

•  These door closers should NOT be installed on exposed side 

(weather side) of exterior doors.

•  Dimensions are given in inches (millimeters).

ATTENTION:

 

An incorrectly installed or improperly adjusted door closer can 

cause property damage or personal injury. These installation 

instructions should be followed to avoid the possibility of 

misapplication or misadjustment.

J1600 UniTrol Arm Closer

Closer Adjustments 

Latch

Backcheck

Use provided 1/8" hex wrench to 

turn valves.  

NEVER force valves out of closer.  

NEVER completely close 

backcheck valve. Backcheck  

is not a positive stop. 

Door must be open to adjust 

spring closing power. Refer to 

chart.  

Do not use a power drill. 

Warranty will be void.

Sweep

2

3

4

5

6

8

10

11

12

14

Top

Jamb

Do not over tighten 

screws

Pinion Cap

Screw pinion cap onto pinion 

shaft by hand or with a Phillips 

screwdriver.

Содержание Norton J1600 UniTrol

Страница 1: ...ion Pour plus d informations visitez www P65warnings ca gov This product can expose you to lead which is known to the state of California to cause cancer and birth defects or other reproductive harm For more information go to www P65warnings ca gov WARNING Tools Needed TO DETERMINE HAND OF YOUR DOOR LEFT HAND DOOR RIGHT HAND DOOR Right Hand Reverse Left Hand Reverse To Determine Your Hand of Door ...

Страница 2: ...l All 9 32 7 00mm thru 3 8 9 50mm dia x 3 8 9 500mm deep door face opposite to closer Always consult door frame manufacturer for fastener compatibility Adjust closing time speed between 4 and 7 seconds from 90 to 0 Use of door by handicapped elderly or small children may require greater closing time These door closers should NOT be installed on exposed side weather side of exterior doors Dimension...

Страница 3: ...2 9 1 16 230 2 3 4 19 1 1 2 13 3 3 4 95 2 51 4 1 8 104 8 C L A Hinge or Pivot Opening Dimension A Hold Open Stop Inches mm 85 90 9 1 8 232 90 95 8 3 8 213 95 100 7 3 4 197 100 105 7 3 8 187 105 110 6 3 4 171 110 115 6 1 2 165 Hollow Metal or Wood Openings Template Aluminum Openings Template 9 1 16 230 2 3 4 19 1 1 2 13 3 3 4 95 1 25 4 1 8 104 8 C L A Hinge or Pivot 1 Prepare door and frame Arm Ide...

Страница 4: ...A Phone 800 438 1951 ext 6030 TechSupport Norton assaabloy com nortondoorcontrols com You ve now installed the 1600 UniTrol Arm Closer Top Jamb Mount Go to page 2 for closer adjustments and decorative cap installation S x4 S and L valves TOWARD hinge 2 Mount closer 3b Install separate arms RH and LH Position flat at S 4 Connect arms and install rod screws 5 Preload spring and tighten rod screws 1s...

Отзывы: