Copyright © 2014 Corbin Russwin, Inc. All rights reserved.
Reproduction in whole or in part without the express written
permission of Corbin Russwin, Inc. is prohibited.
®
ASSA ABLOY
ML20900 ECL Series Mortise Lock
15
ML20906
Electric
Mortise Lock
Wire Transfer
Hinge
EPT
EPTL
BPS
115VAC
Input
2 x 18AWG
To Fire Alarm
Power
Supply
Wires in
Conduit
(If Frames
Are Filled)
Operation:
Free egress at all times. Door is locked at all times preventing
entry from the stairwell to a floor. Fire alarm activation will allow
re-entry from the stairwell to the floor. Power failure will allow
re-entry from the stairwell to the floor.
ML20906
Electric
Mortise Lock
Wire Transfer
Hinge
EPT
EPTL
BPS
115VAC
Input
2 x 18AWG
Power
Supply
Wires in
Conduit
(If Frames
Are Filled)
Access
Control
Reader
HID
Prox
Operation:
Free egress at all times. Door is locked at all times preventing
unauthorized entry. Authorized entry is permitted by presenting a
valid user card.
Tower Stairwell
Access Control on Employee Entrance
ML20906 x
M91 x M92
Electric
Mortise Lock
Wire Transfer
Hinge
EPT
EPTL
BPS
115VAC
Input
2 x 18AWG
6 x 22AWG
Power
Supply
Wires in
Conduit
(If Frames
Are Filled)
Access
Control
Reader
HID
Prox
Alarm Horn
Operation:
Free egress at all times. User exits through the door which
triggers the M92 switch which shunts the alarm. Door is locked
at all times preventing unauthorized entry. Authorized entry is
permitted by presenting a valid user card. Forced entry will trigger
M91 switch and activate alarm. Alarm is deactivated by a valid
user card.
Controlled Entry With Alarm
Consult factory for electrical system layouts, riser and wiring diagrams.
®
ElectroLynx a system of universal
®
Molex plug-in connectors and
standardized color-coded wiring,
makes installing electrified doorway
components a snap!
6) Wiring Diagrams