Assa Abloy medeco Aperio M100 Скачать руководство пользователя страница 9

 

 
 
Step 8:  

Install thumbturn (Fig. 18), set screw (Fig. 19), and re-install door edge trim (Fig. 20). 

 

        

 

           Fig. 18          

  

 

      Fig. 19                                                                         Fig. 20 

 

 

 

 
 

Warning:

 

FCC

 

Statement

 

This

 

device

 

complies

 

with

 

Part

 

15

 

of

 

the

 

FCC

 

Rules.

  

Operation

 

is

 

subject

 

to

 

the

 

following

 

two

 

conditions:

 

1.

 

This

 

device

 

may

 

not

 

cause

 

harmful

 

interference,

 

and

 

2.

 

This

 

device

 

must

 

accept

 

any

 

interference

 

received,

 

including

 

interference

 

that

 

may

 

cause

 

undesired

 

operation.

 

 

Changes

 

or

 

modifications

 

not

 

expressly

 

approved

 

by

 

the

 

manufacturer

 

could

 

void

 

the

 

user’s

 

authority

 

to

 

operate

  

this

 

equipment.

 

 
 

Le

 

présent

 

appareil

 

est

 

conforme

 

aux

 

CNR

 

d'Industrie

 

Canada

 

applicables

 

aux

 

appareils

 

radio

 

exempts

 

de

 

licence.

 

L'exploitation

 

est

 

autorisée

 

aux

 

deux

 

conditions

 

suivantes

 

:

 

(1)

 

l'appareil

 

ne

 

doit

 

pas

 

produire

 

de

 

brouillage,

 

et

 

(2)

 

l'utilisateur

 

de

 

l'appareil

 

doit

 

accepter

 

tout

 

brouillage

 

radioélectrique

 

subi,

 

même

 

si

 

le

 

brouillage

 

est

 

susceptible

 

d'en

 

compromettre

 

le

 

fonctionnement.

 

 

 

 

 
 
 
 
 
 
 
 

Содержание medeco Aperio M100

Страница 1: ...2 4 GHz IEEE 802 15 4 using AES 128bit encryption Hub Power Requirement 8 24VDC 250mA Lock Battery Type CR2 providing 30 000 Cycles Operating Temperature 10C to 50C FCC Part 15 Class B Compliant Crede...

Страница 2: ...to an access control system through the included communication hub The communication hub connects to the access control system with wiegand wiring typical of a wiegand reader When a credential card is...

Страница 3: ...ference For a stable and reliable radio link it is recommended that the hub is located within forty five 45 feet of the lock A maximum of two interior walls between the hub and lock is recommended Rec...

Страница 4: ...includes three form C relays that can be used to transmit Lock jamb status low battery signal and a tamper signal The hub connects to the mortise lock wirelessly Note the Green LED input is used to gr...

Страница 5: ...ents to function properly with the mortise hardware The following steps outline the mechanical installation only Removal of Existing Cylinder a Remove the door edge trim by removing the retaining scre...

Страница 6: ...proud of the escutcheon approximately 3 16 1 4 Please also see Fig 12 before proceeding Fig 6 Fig 5 Fig 6 Step 3 Re tighten the cylinder clamp screw with the M100 in a vertical position The screw sho...

Страница 7: ...Only one or two threads should be visible for proper operation Fig 11 Fig 10 Fig 11 Step 5 Connect control unit to wire harness and install 4 mounting screws Fig 12 and Fig 13 Warning Avoid pinching w...

Страница 8: ...ase verify the battery is inserted in the correct polarity position Always use new batteries installed with correct polarity Fig 14 and 15 Fig 14 Fig 15 Step 7 Install cover assembly Fig 16 and cover...

Страница 9: ...nterference that may cause undesired operation Changes or modifications not expressly approved by the manufacturer could void the user s authority to operate this equipment Le pr sent appareil est con...

Страница 10: ...rn is not out far enough refer to Step 4 Fig 12 The cover does not sit flush on plate Cylinder is protruding out to far included are optional spacers for proper spacing of cylinders refer to Step 4 Fi...

Отзывы: