background image

of 4

HES

®

 Aperio

®

 ES100-15 | 16  

Electric Strike 

Installation & Operating Instructions

Product Contents

A  ES100 Reader
B  ES100 Floor
C  ES100 15/16 Strike Body
 Torx T8 4-40 x 1/4" Security Screw
E  5/64" Hex Wrench
F  Torx T8 Driver Security Bit
G  Trim Enhancer
Alcohol Swab 
I  AA Lithium Batteries

•   Security  Variant: LM/DPS Kit (Not shown)
•   Wholesale  Kit Pre-paired Wiegand 1:1 Hub (Not Shown)

A

B

C

Diagram 1: 

Product Components

D

E

F

G

H

I

Faceplate Options

4-7/8" x 1-1/4" Square Opening  
   = Center line of faceplate (2nd line = center line of faceplate opening) 

1J

For Use With: 

Cylindrical Locksets 

with up to 3/4" throw and all 

locksets with center-lined bolts

1K

For Use With: 

Mortise locksets 

with up to 3/4" throw latchbolt

1KD

For Use With: 

Mortise locksets 

with up to 3/4" throw latchbolt

1KM

For Use With: 

Mortise locksets with 

up to 3/4" throw latchbolt

1-23/32" 

[43.64mm]

1-37/64" 

[40.08mm]

29/32" 

[23.39mm]

1-11/32" 

[34.11mm]

27/32" 

[21.46mm]

1-1/16" 

[27.3mm]

1-11/32" 

[34.11mm]

23/32" 

[18.22mm]

9/32" 

[15.46mm]

1-15/32" 

[37.29mm]

1-3/32" 

[27.81mm]

Compatible:

 All brands of cylindrical latchbolts

Compatible:

 Baldwin, Marks, PDQ

Compatible:

 Dorma (9500), Jackson, 

Sargent (7700, 8100), Schlage, Yale (8700)

Compatible:

 Accurate, Arrow, Best, Corbin Russwin, 

Falcon, Sargent (7800, 8200, 9200), Yale (8700)

1N

For Use With: 

Mortise locksets 

with deadbolt for night latch 

function only

1ND

For Use With: 

Mortise locksets 

with deadbolt for night latch 

function only

1NM

For Use With: 

Mortise locksets 

with deadbolt for night latch 

function only

1NTD

For Use With: 

Mortise locksets with 

a normally extended 1" deabolt and 

center-lined deadlatch

7/8" 

[22.23mm]

3/18" 

[79.37mm]

23/32" 

[18.22mm]

5/32" 

[3.97mm]

3/18" 

[79.37mm]

1-9/64" 

[28.83mm]

1/8" 

[3.17mm]

2-7/8" 

[73.02mm]

15/16" 

[23.8mm]

13/16" 

[20.5mm]

23/32" 

[18.22mm]

1-1/2" 

[38.1mm]

1-1/4" 

[32mm]

Compatible:

 Accurate, Baldwin, Marks, Omnia, 

PDQ, Schlage

Compatible:

 Sargent (7700, 8100), Schlage, 

Yale (8700)

Compatible:

 Accurate, Arrow, Baldwin, Best, 

Corbin Russwin, Falcon (45H, 47H, 34H, 37H), 

Marks, Sargent (7800, 8200, 9200), Yale (8800)

Compatible:

 Accurate, Arrow, Baldwin, Marks, Omnia, 

PDQ, Schlage

check

 1500

check

 1600

check

 1600

check

 1500

check

 1600

check

 1500

check

 1600

check

 1500

check

 1600

check

 1600

check

 1600

check

 1600

Product Specifications listed in Appendix 

Содержание HES Aperio ES100-15

Страница 1: ... 3 32 27 81mm Compatible All brands of cylindrical latchbolts Compatible Baldwin Marks PDQ Compatible Dorma 9500 Jackson Sargent 7700 8100 Schlage Yale 8700 Compatible Accurate Arrow Best Corbin Russwin Falcon Sargent 7800 8200 9200 Yale 8700 1N For Use With Mortise locksets with deadbolt for night latch function only 1ND For Use With Mortise locksets with deadbolt for night latch function only 1N...

Страница 2: ...01 6 44 45 31 8 9 53 15 88 31 8 88 9 104 77 123 83 57 15 31 8 44 45 15 88 31 8 3 1 2 88 9 4 1 8 104 77 4 7 8 123 83 Vertical Centerline Vertical Centerline Strike Lock Preparing the Frame Mortise Locksets Please note the horizontal centerline of the electric strike in relation to the centerline of the mortise lockset Metal Jamb Dimensions for Faceplates Cylindrical Locksets Please note the horizon...

Страница 3: ...nd torx bit NOTE Ensure reader is fully seated against the backplate and the screw hole is properly aligned before securing Strike Installation 1 PREP the frame for the electric strike based on PREPARING THE FRAME section NOTE If using a DPS be sure to prep the hole so that the wire harness can reach the back of the electric strike 2 Monitoring Latch monitoring is a factory installed option and is...

Страница 4: ...in fire 4 INSTALL new AA lithium batteries based on proper polarity 5 Reverse steps 2 and 1 to secure the cover to the backplate Diagram 7 Locking screw Micro USB Port For emergency power local hard wired firmware updates use micro USB port located on the side of the R100 reader NOTE Any 5V power jump device can power the ES100 Micro USB Port Power Draw 136 mA Peak at 5 VDC Diagram 8 Micro USB tec...

Страница 5: ...EE Red Flash Access Denied AC Offline Continuous Red Flashes 125 sec every second Lock is Blocked when closing 10 TEN Red Flashes Error in Lock Continuous Yellow Flashes 25 sec every 5 seconds Low Battery Continuous Red Flashes 25 sec every 5 seconds Dead Battery Aperio LED HUB Codes Steady Green Online Steady Green 1 ONE Red Flash Lock Offline Steady Green 2 TWO Red Flashes Access Control Offline...

Страница 6: ...t 2 cet appareil doit accepter toute interference y compris des interférences qui peuvent provoquer un fonctionnement indésirable du périphérique CE Declaration of Conformity content assaabloyusa com doc AADSS1176114 Product Specifications Approvals CE FCC IC Wireless Frequency 2 4GHz IEEE 802 15 4 using AES 128 bit encryption AA Lithium Energizer L91 Rated 1 5 VDC 3 Ah NOTE Replace Battery With E...

Отзывы: