Product Description

T

he 9400/9500/9600 series electric strike 

installation template (see Figure 1) provides an 

easy means to assist with the installation of any 

of the following:

•  HES 9400 series slim-line, surface mounted 

   electric strike for use with a 1/2" throw
   latchbolt
•  HES 9500 series 3-hour fire-rated, surface  

   mounted electric strike for use with a 3/4"  

   throw latchbolt
•  HES 9600 series windstorm-rated, 

   surface-mounted, electric strike for use with  

   a 3/4" throw latchbolt

Using the Installation Template

1.  REMOVE the existing strike plate from the  

     door.

NOTE:  The 9400/9500/9600 series electric strike 

            installation template keeper block is  

            factory pre-set to the 9500/9500S/9600  

            electric strike position.  The keeper block  

            would need to be repositioned to the 9400  

            position for use with the 9400 series  

            electric strike.

2.  CONFIGURE template for the appropriate  

     strike (see Figure 2).

     [a]  REMOVE the two 6-32 x 3/8" screws   

           securing keeper block to the template 

           plate.

     [b]  ROTATE the keeper block to the proper  

           position (flat side with correct electric  

           strike number showing should face to the  

           left side of the template plate).

     [c]  SECURE the keeper block to the template 

           plate with the two 6-32 x 3/8" screws.

NOTE:  The 9400/9500/9600 series electric  

            strike installation template has magnetic 

            tape to keep it in place on the metal  

            door frame.

3.  ALIGN the template on the door frame, and  

     ENSURE the door latchbolt is properly aligned  

     both horizontally and vertically with respect  

     to the keeper block.

NOTE:  Corbin Russwin ED4200, ED5200  

            and Yale 7100 rim exit devices require  

            that the deadlatch be above the  

            deadlatch vertical alignment line etched  

            on the template in order to latch  

            properly.

4.  DETERMINE the horizontal centerline of the  

     exit device deadlatch to the keeper block  

     using the center alignment sight in the  

     template, and ADJUST as necessary (see  

     Figure 1).

5.  OPEN door, leaving the template in place.

6.  MARK the upper and lower positions for  

     the electric strike mounting holes using the  

     "PRE-DRILL WITH 0.201 (#7 bit)" holes on  

     the template, the power wire exit hole, and  

     the LBM/LBSM wire exit hole (as required).

7.  CENTER PUNCH and DRILL the electric strike  

     mounting holes, wire exit hole, and 

     LBM/LBSM  hole using a #7 drill bit  

     (approximately 13/64").

8.  TAP the drilled electric strike mounting holes  

     using the 1/4"-20 UNC tap.

9.  TEST FIT the electric strike to ensure full  

     deadlatch engagement.

10. INSTALL electric strike in accordance with  

      installation instructions.