2
3026006.001, Rev. B
Product Description
T
he 9400/9500/9600 series electric strike
installation template (see Figure 1) provides an
easy means to assist with the installation of any
of the following:
• HES 9400 series slim-line, surface mounted
electric strike for use with a 1/2" throw
latchbolt
• HES 9500 series 3-hour fire-rated, surface
mounted electric strike for use with a 3/4"
throw latchbolt
• HES 9600 series windstorm-rated,
surface-mounted, electric strike for use with
a 3/4" throw latchbolt
Using the Installation Template
1. REMOVE the existing strike plate from the
door.
NOTE: The 9400/9500/9600 series electric strike
installation template keeper block is
factory pre-set to the 9500/9500S/9600
electric strike position. The keeper block
would need to be repositioned to the 9400
position for use with the 9400 series
electric strike.
2. CONFIGURE template for the appropriate
strike (see Figure 2).
[a] REMOVE the two 6-32 x 3/8" screws
securing keeper block to the template
plate.
[b] ROTATE the keeper block to the proper
position (flat side with correct electric
strike number showing should face to the
left side of the template plate).
[c] SECURE the keeper block to the template
plate with the two 6-32 x 3/8" screws.
NOTE: The 9400/9500/9600 series electric
strike installation template has magnetic
tape to keep it in place on the metal
door frame.
3. ALIGN the template on the door frame, and
ENSURE the door latchbolt is properly aligned
both horizontally and vertically with respect
to the keeper block.
NOTE: Corbin Russwin ED4200, ED5200
and Yale 7100 rim exit devices require
that the deadlatch be above the
deadlatch vertical alignment line etched
on the template in order to latch
properly.
4. DETERMINE the horizontal centerline of the
exit device deadlatch to the keeper block
using the center alignment sight in the
template, and ADJUST as necessary (see
Figure 1).
5. OPEN door, leaving the template in place.
6. MARK the upper and lower positions for
the electric strike mounting holes using the
"PRE-DRILL WITH 0.201 (#7 bit)" holes on
the template, the power wire exit hole, and
the LBM/LBSM wire exit hole (as required).
7. CENTER PUNCH and DRILL the electric strike
mounting holes, wire exit hole, and
LBM/LBSM hole using a #7 drill bit
(approximately 13/64").
8. TAP the drilled electric strike mounting holes
using the 1/4"-20 UNC tap.
9. TEST FIT the electric strike to ensure full
deadlatch engagement.
10. INSTALL electric strike in accordance with
installation instructions.