3
Installation (continued)
LBM Wiring
White
Orange
Normally Open
Green
Normally Closed
Common
LBSM Wiring
Brown
Blue
Common
Note 1: The 5200 series Electric Strikes are
pre-set for FAIL SECURE OPERATION.
Note 2: There are two #2-56 screws located
on the back of the strike for coverting
the operation mode.
10. To convert from FAIL SECURE OPERATION
to FAIL SAFE OPERATION, LOOSEN the two
#2-56 screws located on the back of the
strike, but DO NOT REMOVE them.
11. MOVE the Selector Stop Pins to the FAIL
SAFE OPERATION position as pictured in
Diagram 5.
12. TIGHTEN the two #2-56 screws to secure
the strike in FAIL SAFE OPERATION.
13. VERIFY the 5200 is now in FAIL SAFE
OPERATION.
14. IF the 5200 still operates as FAIL SECURE,
THEN ENSURE the #2-56 screws are fully
seated and tightened.
Diagram 5: FAIL SAFE OPERATION Mode Setting
Brown
Blue
Yellow
White
Orange
Green
DI
LOCKSETS
Converting the Operation Mode
Diagram 4: Latchbolt Strike Monitor
Verifying the Operation Mode
15. TURN the horizontal adjustment screws slowly to
adjust the strike in-frame, as shown in Diagram 6.
16. DO NOT REMOVE the screws or ROTATE them more
than 3 full turns.
17. TIGHTEN the screws securely once the strike has
been adjusted to allow the K-Nut teeth to dig into
the strike housing and prevent slippage during use.
Adjusting the Horizontal
Diagram 6: Horizontal Adjustment
K-NUT
b
Horizontal
Adjustment
Screws
Normally Closed
Normally Open
Yellow
Yellow
Diagram
3
: Latchbolt Monitor