8
Surface Vertical Rod
Installation Instructions
Exit Devices
FM164 09/19
Copyright © 2013, 2019, ASSA ABLOY Access and Egress Hardware Group, Inc. All rights reserved. Reproduction in whole
or in part without the express written permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.
For installation assistance contact Corbin Russwin
1-800-543-3658 • [email protected]
d
Clear Raised Door Molding
Device must seat flush on door surface or on
the shims that keep it parallel to door face.
Longer mounting screws are needed when
more than (2) shims of 1/8" thick are used.
See Shim Kit Option in Step 1e.
e
Size Device
Device must be field-cut to size unless standard opening and device are 36" (0.91 m).
LHR Door Open 90˚ Inside Face (Figure 12)
CL
Figure 12
Align mounting holes in door
with mounting holes in device.
Align horizontal line on door
with edge of device.
Centerline of
dogging hole
No gap between
end cover &
touch bar.
Mark cutoff line.
Cut square on line.
Minimum
Minimum to stile edge
Minimum
1-11/16"
(43 mm)
3/4"
(19 mm)
1-15/16"
(43 mm)
1/2"
(13 mm)
Standard
Figure 11
(1) Shim Kit #697F348
per 1/4" (6 mm) of raised molding