ED2400 & ED2400(A) Series Surface Vertical Rod
4
Installation, continued
c
Prepare Rods
Figure 13
Figure 14
Jig
Dia. Thru
1/8"
(3.20 mm)
3/8"
(10 mm)
Rod
(Typical pin end)
Bolt
Bottom
Rod
1/8" x 1/2" Rollpin
Bottom Rod
Connector
32-1/4"
(818 mm)
3-3/4"
(95 mm)
Adjustment left:
1/2" (13 mm) in-out.
PRESS FLUSH
To Lenghten Rods (Figure 13)
• Use Rod Extension(s) to extend Rod to length needed or
longer (2”, 6”, 12”, or 24” Rod Extensions available).
• Cut excess length from end of rod with pin hole.
• Apply screw locking compound (available at automotive parts
store) to Rod Extension(s) male threads. Thread Extension(s)
until seated tight over Rod.
To Cut Rods (Figure 14)
• Cut from the end with pin hole. NEVER CUT THREADED END.
• Press Jig until it bottoms over Rod.
• Drill 1/8” (3 mm) dia. hole thru, 3/8” (10 mm) from end of
Rod.
Bottom Rods (Figure 18)
• Ready for 39-15/16” (1014 mm) Floor to device center.
To Lower Device
• Bottom Rod cutoff length is distance that device was lowered
below 39-15/16” (1014 mm).
• Add to top rod a length equal to the bottom rod cut.
Example:
Device at 36” (914 mm) from floor
39-15/16” - 36” = 3-15/16” (100 mm)
The top rod must be lengthened 3-15/16” (100 mm)