5
DL2200 and DL3200 Series
Installation Instructions
Cylindrical Deadbolts
FM331 10/19
For installation assistance contact Corbin Russwin
1-800-543-3658 • [email protected]
Copyright © 2012, 2019, ASSA ABLOY Access and Egress Hardware Group, Inc. All rights reserved. Reproduction in whole
or in part without the express written permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.
DL2200 and DL3200 Deadbolt Installation (cont .)
a
Install Deadbolt
a. Insert deadbolt unit into hole in door edge, making certain that tab on deadbolt is facing up as shown
in Figure 5.
b. Fasten deadbolt front and deadbolt assembly to door with two (2) deadbolt screws.
c. Extend the deadbolt by turning the slot in the hub.
Keep deadbolt extended during installation .
b
Install Outside
a. Insert cylinder into outside cylinder housing assembly and fasten it with cylinder screw.
b. For 11-function, 13-function, and 17-function lock installation, shorten cylinder tailpiece if necessary
by breaking it off at the score mark with pliers.
c. Insert outside cylinder housing assembly though housing collar onto door with cylinder tailpiece
going through slot in hub of deadbolt.
d. Mount outside cylinder housing assembly (or outside blank plate) to door with two (2) 1/4-20
mounting screws and appropriate mounting plate.
c
Install Inside
a. For 12-function lock installation, insert cylinder with tailpiece going through slot in hub of deadbolt
(flat side of cylinder, tailpieces meet within slot). For 60-function lock installation, insert tailpiece into
the slot of hub of deadbolt.
b. For 12-function lock installation, place inside cylinder housing assembly over the cylinder, making
certain that tab is engaged in keyway slot. Insert key and turn until screw holes are exposed. For
13-function and 17-function lock installation, place thumbturn assembly onto tailpiece and align
screw holes.
c. For DL3200 series lock installation, use two (2) #8-32 screws to fasten inside cylinder housing
assembly (or inside trim) to the assembly. For DL220 series lock installation, use two (2) 1/4-20 oval
head screws.
d.
IMPORTANT:
Operate deadbolt from both sides of door to check for proper operation. If binding
occurs, recheck the door preparation and complete the installation procedure.
d
Install Strike