![Assa Abloy Arrow AL-500 Series Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/assa-abloy/arrow-al-500-series/arrow-al-500-series_installation-instructions-manual_2988827005.webp)
A8265A 08/19
5
AL-500 Series
Installation Instructions
Alarmed Exit Devices
1-800-327-8539 • www.arrowlock.com
Copyright © 2019, ASSA ABLOY Access and Egress Hardware Group, Inc. All rights reserved.
Reproduction in whole or in partwithout the express written permission of ASSA ABLOY Access and
Egress Hardware Group, Inc. is prohibited.
5
Apply Rail Assembly
1. Depress lift arm into rail assembly and slide rail onto chassis.
2. Attach rail assembly to chassis with two (2) #8 truss head machine screws. Do not tighten screws
3. Secure chassis to door with four (4) #10 flat head screws. (Figure 8)
4. Level rail.
5. Place mounting plate tight against rail and attach to door with two (2) #10 round head screws.
6. Tighten all screws securely (Figure 7).
Figure 6
Lift Arm
Level
Mounting Plate
Rail Assembly
Rail Mounting Screw (2 Places)
(#8-32 x 3/8 PH. Truss HD. Machine Screw)
Mounting Plate
Mounting Plate Screws
(#10-24 x 3/4
"
PH. RD. HD. Machine Screw)
Figure 7
Chassis Mounting Screws
(1/4-20 x5/8 PH. FL. HD.
Machine Screws)
Four (4) places
Figure 8
6
Installation Instructions
• These instructions are for the AL500 Series exit device, which is designed for areas requiring field
selectable time delay and automatic alarm reset options.
• Verify hand and bevel of door. Exit devices are always reverse bevel and mounted on inside of door.
Left Hand Reverse Bevel Hinges
Left. Open Outward LHRB
Inside View
Outside View
Inside View
Outside View
Right Hand Reverse Bevel Hinges
Left. Open Outward RHRB
LHRB Shown
RHRB Shown
Figure 9
1. Installation must be performed by a trained and experienced service person.
2. 9V battery operated.