5
AH40 - Connectors
Note:
When PoE (Power over Ethernet) is used, no power supply
should be connected to J321. The installation must comply with
national wiring regulations.
C
onneCtors
D
esCription
J201
Ethernet connector. Connection to the Electronic Access
Control system through a 10BASE-T / 100BASE-TX Local
Area Network. Can also be used for power supply if
connected to a IEEE 802.3af compliant Power Sourcing
Device (PSE). Wire requirements CAT5 or higher.
J321
Power supply input, 8-24 VDC, 3.5 W. The power supply
shall be a Limited Power Source (LPS) according to EN
60950-1. The power supply shall be 3 A over current
protected. Wire requirements 16-22 AWG.
8-24V
- +
LINK
PAIR
J201
J321
ANTENNA
EXT INT