background image

4

AH20/AH30 - Placement of Communication Hub

AH20/30 - Placement of the Hub, 1 door

Note: AH20/AH30 can be installed with an Aperio bottom cover or 

Americas adaptor plate.

< 15 m / ~ 50 f

t

AH30 (RS485 Hub) - Placement of the Hub, 1-8 doors

Note: Note: AH20/AH30 must be installed into a junction box ex 

European 2-Gang, Aperio bottom cover or with Americas adaptor 

plate to junction box. AH20/AH30 must be installed by qualified 

and trained personal. Indoor installation only! 

< 15 m / ~ 50 f

t

Note: 

The Aperio Communication hubs are not rated to be 

installed in the plenum space.

Содержание Aperio AH20

Страница 1: ...1 ASSA ABLOY the global leader in door opening solutions Aperio Hub AH20 AH30 Installation Instructions ...

Страница 2: ...ion Table 8 AH30 J100 Connections 9 AH30 DIP Switch Configuration Table 10 AH30 RS485 Bus Connection 11 AH30 RS485 Addressing 12 13 AH20 AH30 Communication Hub LED Indication 14 AH20 AH30 Technical Data 15 ETL marking Recognized component Conforms to ANSI UL standard 294 ANSI UL 60950 1 Certified to CAN CSA standard C22 2 No 60950 1 4002570 AH20 AH30 Table of Contents ...

Страница 3: ... présent appareil est conforme aux CNR d Industrie Canada applicables aux appareils radio exempts de licence L exploitation est autorisée aux deux conditions suivantes 1 l appareil ne doit pas produire de brouillage et 2 l utilisateur de l appareil doit accepter tout brouillage radioélectrique subi même si le brouillage est susceptible d en compromettre le fonctionnement The term IC before the equ...

Страница 4: ...ft AH30 RS485 Hub Placement of the Hub 1 8 doors Note Note AH20 AH30 must be installed into a junction box ex European 2 Gang Aperio bottom cover or with Americas adaptor plate to junction box AH20 AH30 must be installed by qualified and trained personal Indoor installation only 15 m 50 ft Note The Aperio Communication hubs are not rated to be installed in the plenum space ...

Страница 5: ...th national wiring regulations A B D1 D0 RED GREEN GND 8 24V J100 S100 S101 J103 NCL1 COM1 NOP1 NCL2 COM2 NOP2 NCL3 COM3 NOP3 NCL4 COM4 NOP4 1 2 3 4 5 6 7 8 9 10 ON K500 K501 K502 K503 A B D1 D0 RED GREEN GND 8 24V J100 S100 S101 J103 NCL1 COM1 NOP1 NCL2 COM2 NOP2 NCL3 COM3 NOP3 NCL4 COM4 NOP4 1 2 3 4 5 6 7 8 9 10 ON K500 K501 K502 K503 ...

Страница 6: ...witch 1 is selected OFF Signal is active low GREEN Wiegand Green LED signal Input to Communication Hub Used for access decision Signal is active low See DIP 1 for alternate instructions GND GND Signal ground Should be connected to EAC system GND and power supply GND 8 24 VDC Power supply input 8 24 VDC 2 W AH20 J100 Connections Communication Hub hardware version AH20 has four Wiegand signals plus ...

Страница 7: ...ays is to provide door status information to the EAC system Relays Description Relay 1 K500 DPS Door Position Relay 2 K501 RX Request to exit Relay 3 K502 Battery Alarm Output Relay 4 K503 Tamper Alarm Output Lock Jammed Relay Contacts Description NCL Normally Closed COM Common NOP Normally Open A B D1 D0 RED GREEN GND 8 24V J100 S100 S101 J103 NCL1 COM1 NOP1 NCL2 COM2 NOP2 NCL3 COM3 NOP3 NCL4 COM...

Страница 8: ...FF Addition of parity bits is disabled Credentials are transmitted as received 4 A3 Controls byte order of transmitted credentials ON The byte order is reversed on the Wiegand interface compared to what is received from the Aperio lock OFF The byte order is left as is 5 A4 Used in Pairing Mode ON Starts in pairing mode OFF Normal use 6 8 Not applicable only used for AH30 9 Not used 10 INT EXT Inte...

Страница 9: ... Should be connected to EAC system GND and power supply GND 8 24 VDC Power supply input 8 24 VDC 1 1 W Note The installation must comply with national wiring regulations A B D1 D0 RED GREEN GND 8 24V J100 S100 S101 J103 NCL1 COM1 NOP1 NCL2 COM2 NOP2 NCL3 COM3 NOP3 NCL4 COM4 NOP4 1 2 3 4 5 6 7 8 9 10 ON K500 K501 K502 K503 ...

Страница 10: ...cted disabled 7 UP Controls use of RS485 and pull up resistor ON 620 Ohm pull up connected enabled OFF 620 Ohm pull up disconnected disabled 8 TERM Controls use of termination resistor between RS485 A and RS485 B ON 100 Ohm termination resistor connected enabled OFF 100 Ohm termination resistor disconnected disabled 9 Not used 10 INT EXT Controls use of external antenna if required ON Selects use ...

Страница 11: ... A Termination enabled B A B A B Hub 1 DIP 6 OFF DIP 7 OFF DIP 8 OFF Hub 2 DIP 6 OFF DIP 7 OFF DIP 8 OFF Hub N End of Bus DIP 6 ON DIP 7 ON DIP 8 ON EAC system A B A Termination enabled B A B Hub 2 DIP 6 OFF DIP 7 OFF DIP 8 ON Hub 1 DIP 6 ON DIP 7 ON DIP 8 ON Note The RS485 bus cable should be of type twisted pair The maximum cable length of 1000 meters should not be exceeded ...

Страница 12: ...ress A0 A1 A2 A3 A4 0 Pairing Active 1 ON 2 ON 3 ON ON 4 ON 5 ON ON 6 ON ON 7 ON ON ON 8 ON 9 ON ON 10 ON ON 11 ON ON ON 12 ON ON 13 ON ON ON 14 ON ON ON 15 ON ON ON ON Address examples AH30 RS485 Addressing ...

Страница 13: ...16 ON 17 ON ON 18 ON ON 19 ON ON ON 20 ON ON 21 ON ON ON 22 ON ON ON 23 ON ON ON ON 24 ON ON 25 ON ON ON 26 ON ON ON 27 ON ON ON ON 28 ON ON ON 29 ON ON ON ON 30 ON ON ON ON 31 ON ON ON ON ON Address examples A4 is only supported on AH30 in 1 1 mode ...

Страница 14: ...30 Communication Hub LED Indication Green Online Green One Red Flash Aperio Lock Offline Green Two Red Flashes EAC Offline Green Three Red Flashes Aperio Lock and EAC Offline Yellow Off Fast Flash UHF Communication Yellow Pairing Active Note With the software tool Aperio Programming Application and a USB radio dongle further system installation parameters can be set ...

Страница 15: ...m 50 ft depending upon installed environment Internal Antenna Two cross polarized dipoles External Antenna One reverse polarity SMA external antenna connector AH20 30 is certified and is only allowed to be used with ASSA ABLOY external antenna AH ANTENNA 1 Operating Temperature 5 C to 35 C Humidity 95 non condensing IP Classification IP20 Safety and Emissions FCC 47CFR 2016 Part 15 subpart B and s...

Страница 16: ...16 www assaabloy com aperio ASSA ABLOY the global leader in door opening solutions D000732543 F US ...