Safety instructions

Warning!

Danger arising from modification of the product:

 The safety features of this 

product are an essential requirement for its conformity with EltVTR. No changes 
which are not described in this manual may be undertaken.

Danger due to faulty commissioning: 

In order to ensure the safety of the 

product, commissioning must be performed by a qualified person. 

ASSA ABLOY 

Sicherheitstechnik GmbH

 offers training for qualification in the requisite skills.

Any work on electrical connections may only be carried out on the 

TSB Controller

 

and control devices when they are in a de-energised state to eliminate any risk 
of physical injury or damage to the equipment. Observe VDE regulations in this 
respect.

Danger due to faulty maintenance:

 The owner is responsible for correct instal-

lation and functional inspection of the product and connected components. The 
safe function must be tested by a trained qualified expert at least once per year. 
Requirements established by inspection authorities must be complied with. 

ASSA 

ABLOY Sicherheitstechnik GmbH

 offers training for qualification in the requisite 

skills.

Caution!

Risk of injury due to damage: 

The device must not be used if it is damaged. 

Damaged cables and connector assemblies also represent a safety hazard and 
must not be used.

!

!

Содержание 970-TSBC-30-00

Страница 1: ...Experience a safer and more open world assaabloyopeningsolutions de D0126601 User manual TSB Controller II Escape route technology...

Страница 2: ...2021 ASSA ABLOY Sicherheitstechnik GmbH This document and all its parts are copyrighted Any use or changes outside the strict limits of the copyright are prohibited and liable to prosecution unless pr...

Страница 3: ...wiring 10 Bus controller installation 11 Power supply 11 Connections 12 Resetting to factory settings 14 Replacing the battery 14 LED signalling 15 Set up operation 16 Check list 16 Turning on the sys...

Страница 4: ...fer Meaning of the symbols Danger Safety notice Failure to observe these warnings will lead to death or serious injury Warning Safety notice Failure to observe these warnings may lead to death or seri...

Страница 5: ...ntroller and control devices when they are in a de energised state to eliminate any risk of physical injury or damage to the equipment Observe VDE regulations in this respect Danger due to faulty main...

Страница 6: ...er II and the individual escape door control units or control terminals peripherals takes place via the TS bus The TSB Controller II must be mounted on top hat rails in accordance with DIN EN 60715 TH...

Страница 7: ...iguration and parametrisation for systems and devices Events logging Maintenance module As a central interface the FT Manager web interface offers the system integrator the option of integrating confi...

Страница 8: ...l units or escape door control terminals and connected components such as escape door strikes and emergency open switches remain operative for safety reasons Control and monitoring Peripherals and esc...

Страница 9: ...omply with safety regulations regarding work on electrical sys tems Important Components at risk of electrostatic discharge Electronic components in equipment should not be touched to ensure that elec...

Страница 10: ...ls to the bus We recommend using telecommunications cable type J Y St Y with a cross section of 0 28 mm or 0 5 mm Do not use free wires in the bus line for additional control tasks or power supply to...

Страница 11: ...itions such as ag gressive vapours or high humidity The TSB Controller II should be easily accessible in a protected area and not be exposed to direct sunlight When mounting the TSB Controller IIon th...

Страница 12: ...c no nc c no nc c no 2 11 12 14 13 ON 3 4 6 7 5 10 8 Functional earthing Connection Fire alarm No fire alarm Local connection Central connection Jumper 8 inserted Jumper 8 not inserted 10 9 8 7 Conne...

Страница 13: ...18 Relay 2 no Relay 2 c Relay 2 nc 6 19 20 21 Relay 3 no Relay 3 c Relay 3 nc 7 22 23 24 Relay 4 no Relay 4 c Relay 4 nc 8 Jumper plug connector for deactivating a fire alarm system Jumper set Fire a...

Страница 14: ...ash 1 1 3 Wait at least 10 seconds Red LED continues to flash 1 1 yellow LED and green LED are off 4 Set DIP switch 2 from ON to OFF again Red LED yellow LED and green LED are on Factory settings are...

Страница 15: ...ooting takes about 20 seconds Only then will the controller take control of the LEDs Off On On Reference run bus scan Normal operation Off Off On Basic state no data traffic Off Flashes 5 1 Data traff...

Страница 16: ...ipheral address Turning on the system Initial operation of peripheral devices 1 Switch on the power supply to each individual peripheral 2 Check each individual peripheral at its installation location...

Страница 17: ...oordination with the network administrator required Configuration for use in the network Escape route technology network structure Fig 3 Network structure TS Bus Repeater 901 35 Service PC FT Manager...

Страница 18: ...d and adjust if necessary to ensure that the TSB Controller can communicate with your PC The bus controller s DHCP server is active ex works 1 Open the Windows settings window Fig 4 1 2 Click Network...

Страница 19: ...19 EN Set up operation Fig 4 Configuring the network connection 1 4 3 2 1 5 7 7 6...

Страница 20: ...C This security certification is trustworthy but the web browser won t recognise it 3 You will therefore need to select Continue to load this website Fig 5 1 The FT Manager will now open in the browse...

Страница 21: ...21 EN Set up operation Fig 5 Note on the safety certificate 1 Fig 6 Start interface of the FT Manager...

Страница 22: ...Ah Battery life approx 5 years varies depending on the quality of the coin cell used Ethernet interface RJ45 Transmission rate 100 MBit s IEEE standard 802 3 100BASE TX TS bus interface 2 wire twisted...

Страница 23: ...product is to be properly disposed of as electronic scrap after use and to be dropped off at a local collection point free of charge for recycling of the materials Important Requirement under German...

Страница 24: ...7431 123 0 Fax 49 7431 123 240 albstadt assaabloy com www assaabloyopeningsolutions de Die ASSA ABLOY Gruppe ist der Weltmarktf hrer in Zugangsl sungen Jeden Tag helfen wir Menschen sich sicherer und...

Отзывы: