4 1
4 1
4 1
4 1
4 1
TRFC1
Use this to adjust TRFC1 values. Configuration options: [Auto], [75ns],
[105ns], [127.5ns], [195ns] and [327.5ns]. The default value is [Auto].
MA Timing
Use this to adjust values for MA timing. Configuration options: [Auto], [2T],
[1T]. The default value is [Auto].
CHA Addr/Cmd Fine Delay
Use this to adjust values for CHA Addr/Cmd Fine Delay feature. Configura-
tion options: [Auto], [No Delay], [1/64CLK] to [31/64CLK]. The default value
is [Auto].
CHA Addr/Cmd Setup Time
Use this to adjust values for CHA Addr/Cmd Setup Time feature. Configura-
tion options: [Auto], [1/2CLK] and [1CLK]. The default value is [Auto].
CHA CS/ODT Fine Delay
Use this to adjust values for CHA CS/ODT Fine Delay feature. Configuration
options: [Auto], [No Delay], [1/64CLK] to [31/64CLK]. The default value is
[Auto].
CHA CS/ODT Setup Time
Use this to adjust values for CHA CS/ODT Setup Time feature. Configura-
tion options: [Auto], [1/2CLK] and [1CLK]. The default value is [Auto].
CHB Addr/Cmd Fine Delay
Use this to adjust values for CHB Addr/Cmd Fine Delay feature. Configura-
tion options: [Auto], [No Delay], [1/64CLK] to [31/64CLK]. The default value
is [Auto].
CHB Addr/Cmd Setup Time
Use this to adjust values for CHB Addr/Cmd Setup Time feature. Configura-
tion options: [Auto], [1/2CLK] and [1CLK]. The default value is [Auto].
CHB CS/ODT Fine Delay
Use this to adjust values for CHB CS/ODT Fine Delay feature. Configuration
options: [Auto], [No Delay], [1/64CLK] to [31/64CLK]. The default value is
[Auto].
CHB CS/ODT Setup Time
Use this to adjust values for CHB CS/ODT Setup Time feature. Configura-
tion options: [Auto], [1/2CLK] and [1CLK]. The default value is [Auto].
CHA CKE Drive Strength
Use this to adjust values for CHA CKE Drive Strength. Configuration options:
[Auto], [1.00x], [1.25x], [1.50x] and [2.00x]. The default value is [Auto].
CHA CS/ODT Drive Strength
Use this to adjust values for CHA CS/ODT Drive Strength. Configuration
options: [Auto], [1.00x], [1.25x], [1.50x] and [2.00x]. The default value is
[Auto].