background image

EPYC3251D4I-2T 
EPYC3151D4I-2T
EPYC3101D4I-2T

EPYC3251D4I-NL

EPYC3101D4I-NL

User Manual

Version 1.1

Published November 2020

Copyright©2020 ASRock Rack INC. All rights reserved.

Содержание EPYC3101D4I-2T

Страница 1: ...EPYC3251D4I 2T EPYC3151D4I 2T EPYC3101D4I 2T EPYC3251D4I NL EPYC3101D4I NL User Manual Version 1 1 Published November 2020 Copyright 2020 ASRock Rack INC All rights reserved...

Страница 2: ...implied including but not limited to the implied warranties or conditions of merchantability or fitness for a particular purpose In no event shall ASRock Rack its directors officers employees or agen...

Страница 3: ...ant to know more about ASRock Rack you re welcome to visit ASRock Rack s website at www ASRockRack com or you may contact your dealer for further information ASRock Rack Incorporation 6F No 37 Sec 2 J...

Страница 4: ...ion Precautions 13 2 3 Installation of Memory Modules DIMM 14 2 4 Expansion Slots PCI Express Slots 16 2 5 Onboard Headers and Connectors 17 2 6 AC IN DC IN Power Connections 22 2 7 Unit Identificatio...

Страница 5: ...uration 37 3 3 7 Serial Port Console Redirection 38 3 3 8 H W Monitor 42 3 3 9 PSP Firmware Versions 44 3 3 10 AMD CBS 45 3 3 11 Instant Flash 46 3 4 Server Mgmt 47 3 4 1 System Event Log 48 3 4 2 BMC...

Страница 6: ...nning The Support CD 63 4 2 2 Drivers Menu 63 4 2 3 Utilities Menu 63 4 2 4 Contact Information 63 Chapter 5 Troubleshooting 64 5 1 Troubleshooting Procedures 64 5 2 Technical Support Procedures 66 5...

Страница 7: ...C3101D4I NL Motherboard Mini ITX Form Factor 6 7 in x 6 7 in 17 02 cm x 17 02 cm Quick Installation Guide 1 x Oculink to 4 SATA Cable 60cm Optional 1 x SATA3 Cable 60cm 1 x SATA Power Cable 80cm 1 x A...

Страница 8: ...B 4GB DIMM Frequency ECC UDIMM 2133 2400 2666 MHz RDIMM 2133 2400 2666 MHz the max speed may vary based on SoC SKU Expansion Slot PCIe 3 0 x 16 SLOT7 Gen3 x16 link Storage SATA Controller AMD Built in...

Страница 9: ...d IPMI LAN port LAN Ports with LED ACT LINK LED and SPEED LED UID Button 1 USB 3 2 Gen1 2 Internal Connector COM Header 1 M 2 1 x M Key PCIe3 0 x4 or SATAIII 6 0 Gb s Supports 22110 2280 form factor F...

Страница 10: ...to our website for the latest OS support list Environment Temperature Operation temperature 10 C 35 C Non operation temperature 40 C 70 C Install a CPU Fan when the airflow through the heatsink is be...

Страница 11: ...With this utility you can press the F6 key during the POST or the F2 key to enter into the BIOS setup menu to access ASRock Rack Instant Flash Just launch this tool and save the new BIOS file to your...

Страница 12: ...TX12V2 ATX12V1 OCU1 PCIE7 NUT110 PCIE7 M2_1 NUT80 ATX12V3 SATA_5 SATA_4 1 SATA_SGPIO1 1 USB3_3_4 PANEL1 HDLED RESET PLED PWRBTN 1 ITX_AUX_PANEL1 1 COM1 TPM1 USB 3 2 Gen1 T USB2 B USB1 IPMI LAN X550_LA...

Страница 13: ...SATA3 Connector SATA_4 12 SATA3 Connector SATA_5 13 SATA SGPIO Connector SATA_SGPIO1 14 M 2 Socket M2_1 Type 2280 22110 15 SATA Power Connector ATX12V3 16 USB 3 2 Gen1 Header USB3_3_4 17 System Panel...

Страница 14: ...4 bit 288 pin module Blue DDR4 DDR4_A2 DDR4 White 64 bit 288 pin module 1 FAN3 BAT1 VGA1 UID1 FAN1 1 1 HDLED RESET PLED PWRBTN 1 1 PCIE7 1 2 3 4 5 NUT110 NUT80 No Item Status Description 1 LED_FAN2 Am...

Страница 15: ...PYC3251D4I 2T EPYC3151D4I 2T EPYC3101D4I 2T 10G LAN RJ 45 Port LAN2 EPYC3251D4I NL EPYC3101D4I NL N A LAN Port LED Indications There are two LED next to the LAN port Please refer to the table below fo...

Страница 16: ...port LED indications 10G LAN Port LAN1 LAN2 LED Indications Activity Link LED Speed LED Status Description Status Description Off No Link Off 100Mbps connection or no link Blinking Green Data Activit...

Страница 17: ...lot 7 x16 witch M 2 M Key 22110 2280 1x SATA 3 PCIe 3 0 x4 X550 PCIe3 0 x4 2 x 10G Base T 2x USB 3 1 Gen1 USB 2 0 Rear USB TPM Header AST2500 LPC PCIe x1 Switch RGMII UART VGA PHY Mgmt Port COM Port D...

Страница 18: ...ts DDR4 DIMM 1866 2133 w ECC Slot 7 x16 witch M 2 M Key 22110 2280 1x SATA 3 PCIe 3 0 x4 2x USB 3 1 Gen1 USB 2 0 Rear USB TPM Header AST2500 LPC PCIe x1 Switch RGMII UART VGA PHY Mgmt Port COM Port D...

Страница 19: ...r the like Also remember to use a grounded wrist strap or touch a safety grounded object before you handle the compo nents 3 Hold components by the edges and do not touch the ICs 4 Whenever you uninst...

Страница 20: ...this configuration 1 For dual channel configuration you always need to install identical the same brand speed size and chip type DDR4 DIMM pairs 2 It is not allowed to install a DDR DDR2 or DDR3 memo...

Страница 21: ...EPYCXXXXD4I 2T EPYXXXXD4I NL Series 15 English 1 2 3...

Страница 22: ...unplugged Please read the documentation of the expansion card and make necessary hardware settings for the card before you start the installation Step 2 Remove the system unit cover if your motherboa...

Страница 23: ...to turn off your system using the power switch RESET Reset Switch Connect to the reset switch on the chassis front panel Press the reset switch to restart the computer if the computer freezes and fai...

Страница 24: ...6 No 16 1 IntA_PB_D Dummy IntA_PB_D GND IntA_PB_SSTX GND IntA_PB_SSTX IntA_PB_SSRX IntA_PB_SSRX Vbus Vbus Vbus IntA_PA_SSRX IntA_PA_SSRX GND IntA_PA_SSTX IntA_PA_SSTX GND IntA_PA_D IntA_PA_D Besides...

Страница 25: ...ONTROL GND 4 3 2 1 Please connect the fan cables to the fan connectors and match the black wire to the ground pin All fans supports Fan Control CPU Fan Connectors 4 pin FAN1 see p 6 No 9 GND FAN_VOLTA...

Страница 26: ...ication it is not necessary to use this ATX 4 PIN power connector Caution Misconnection between the ATX12V2 and the ATX12V3 connec tors may permanently damage the motherboard ATX 12V Power Connector 8...

Страница 27: ...ement Bus header 4 pin IPMB_1 see p 6 No 2 IPMB_SDA IPMB_SCL No Connect GND This 4 pin connector is used to provide a cabled baseboard or front panel connection for value added features and 3rd party...

Страница 28: ...ions between the motherboard and the power supply Connector DC IN ATX PSU 12V 8pin O O ATX 4pin X O with the bundled ATX 24pin to 4pin converter cable PSU 12V 8pin ATX 4pin via a 24pin to 4pin Convert...

Страница 29: ...l is pressed the front rear UID blue LED indicator will be turned on Press the UID button again to turn off the indicator 2 8 Driver Installation Guide To install the drivers to your system please ins...

Страница 30: ...ndles all non TCP IP traffic The Secondary adapter will receive fallback traffic if the primary fails If the Preferred Primary adapter fails but is later restored to an active status control is automa...

Страница 31: ...2 Socket supports a M 2 SATA3 6 0 Gb s module or a M 2 PCI Express module up to Gen3 x4 32Gb s If M2_1 is occupied by a SATA type M 2 device SATA_4 will be disabled Installing the M 2_SSD NGFF Module...

Страница 32: ...protective film on the nut to be used Hand tighten the standoff into the desired nut location on the motherboard B A B A 20o Step 5 Align and gently insert the M 2 NGFF SSD module into the M 2 slot P...

Страница 33: ...also restart by turning the system off and then back on 3 1 1 UEFI Menu Bar The top of the screen has a menu bar with the following selections Item Description Main To set up the system time date info...

Страница 34: ...selected items Tab Switch to next function Enter To bring up the selected screen PGUP Go to the previous page PGDN Go to the next page HOME Go to the top of the screen END Go to the bottom of the scr...

Страница 35: ...eries 29 English 3 2 Main Screen Once you enter the UEFI SETUP UTILITY the Main screen will appear and display the system overview The Main screen provides system overview information and allows you t...

Страница 36: ...ed Screen In this section you may set the configurations for the following items CPU Configuration Chipset Configuration Storage Configuration ACPI Configuration USB Configuration Super IO Configurati...

Страница 37: ...T EPYXXXXD4I NL Series 31 English 3 3 1 CPU Configuration Node 0 Information View Memory Information related to Node 0 SVM Mode Enable disable CPU Virtualization CPB Mode Auto disable CPB C6 Mode Enab...

Страница 38: ...LAN2 To enable or disable Onabord LAN PCIE7 Link Width This allows you to select PCIE7 Link Width The default value is Auto PCIE7 Link Speed This allows you to select PCIE7 Link Speed The default valu...

Страница 39: ...abled the Downstream Port disables its traditional Device Number field being 0 enforcement when turning a Type1 Configuration Request into a Type0 Configuration Request permitting access to Extended F...

Страница 40: ...34 English 3 3 3 Storage Configuration In this page you can configure storage devices...

Страница 41: ...ries 35 English 3 3 4 ACPI Configuration PCIE Devices Power On Allow the system to be waked up by a PCIE device and enable wake on LAN RTC Alarm Power On Use this item to enable or disable RTC Real Ti...

Страница 42: ...36 English 3 3 5 USB Configuration Legacy USB Support Use this option to enable or disable legacy support for USB devices The default value is Enabled...

Страница 43: ...Port 1 COM1 Serial Port Use this item to enable or disable the serial port Serial Port Address Use this item to select an optimal setting for Super IO device SOL Configuration Use this item to set par...

Страница 44: ...ure Console Redirection Settings and specify how your computer and the host computer to which you are connected exchange information Terminal Type Use this item to select the preferred terminal emulat...

Страница 45: ...Once the buffers are empty a start signal can be sent to restart the flow Hardware flow uses two wires to send start stop signals The options include None and Hardware RTS CTS VT UTF8 Combo Key Suppo...

Страница 46: ...lows for remote management of a Windows Server OS through a serial port Terminal Type Use this item to select the preferred terminal emulation type for out of band management It is recommended to sele...

Страница 47: ...EPYCXXXXD4I 2T EPYXXXXD4I NL Series 41 English Data Bits Parity Stop Bits...

Страница 48: ...controlled by BMC If Manual is selected configure the items below FAN1 This allows you to set the CPU fan1 s speed The default value is Smart Fan FAN 2 This allows you to set the front fan 2 s speed T...

Страница 49: ...ries 43 English Smart Fan Temp Control Smart Fan Temp x x means 1 to 11 stage This allows you to set temperature for each stage Watch Dog Timer This allows you to enable or disable the Watch Dog Timer...

Страница 50: ...44 English 3 3 9 PSP Firmware Versions You can view information of PSP firmware versions in this page...

Страница 51: ...igure DF Common options UMC Common Options Use this item to configure UMC Common options NBIO Common Options Use this item to configure NBIO Common options FCH Common Options Use this item to configur...

Страница 52: ...isk or hard drive and launch this tool then you can update your UEFI only in a few clicks without preparing an additional floppy diskette or other compli cated flash utility Please be noted that the U...

Страница 53: ...response for specified time out BMC starts at the same time when BIOS starts during AC power ON It takes around 90 seconds to initialize Host to BMC interfaces Inventory Support Use this item to execu...

Страница 54: ...g for error progress codes during boot Erase SEL Use this to choose options for earsing SEL When SEL is Full Use this to choose options for reactions to a full SEL Log EFI Status Codes Use this item t...

Страница 55: ...ssigned by DHCP If you prefer using a static IP address toggle to Yes and the changes take effect after the system reboots The default value is No Configuration Address Source Select to configure BMC...

Страница 56: ...r more instructions on how to set up remote control environment and use the IPMI man agement platform please refer to the IPMI Configuration User Guide or go to the Support website at http www asrockr...

Страница 57: ...and press enter to remove the password User Password Set or change the password for the user account Users are unable to change the settings in the UEFI Setup Utility Leave it blank and press enter to...

Страница 58: ...re Boot Keys Please install default secure boot keys if it s the first time you use secure boot Clear Secure Boot keys Force System to Setup Mode clear all Secure Boot Variables Change takes effect af...

Страница 59: ...IGNATURE_LIST b EFI_CERT_X509 DER c EFI_CERT_RSA2048 bin d EFI_CERT_SHA256 384 512 2 Authenticated UEFI Variable 3 EFI PE COFF Image SHA256 Key Source Factory External Mixed Key Exchange Keys Enroll F...

Страница 60: ...s from a file 1 Public Key Certificate in a EFI_SIGNATURE_LIST b EFI_CERT_X509 DER encoded c EFI_CERT_RSA2048 bin d EFI_CERT_SHA256 384 512 2 Authenticated UEFI Variable 3 EFI PE COFF Image SHA256 Key...

Страница 61: ...y Signatures Enroll Factory Defaults or load certificates from a file 1 Public Key Certificate in a EFI_SIGNATURE_LIST b EFI_CERT_X509 DER encoded c EFI_CERT_RSA2048 bin d EFI_CERT_SHA256 384 512 2 Au...

Страница 62: ...r This option controls Legacy UEFI ROMs priority Boot From Onboard LAN Use this item to enable or disable the Boot From Onboard LAN feature Setup Prompt Timeout Configure the number of seconds to wait...

Страница 63: ...Display Use this option to adjust AddOn ROM Display If you enable the option Full Screen Logo but you want to see the AddOn ROM information when the system boots please select Enabled Configuration o...

Страница 64: ...on ROM only Select Legacy only to run those that support legacy option ROM only Select Do not launch to not execute both legacy and UEFI option ROM Launch Video OpROM Policy Select UEFI only to run th...

Страница 65: ...he default is Dis abled with NVMe device but it is Legacy with other devices This item can t select Video Option ROM policy M2_1 Slot OpROM To select Slot Storage and Network Option ROM policy In Auto...

Страница 66: ...ry reset If Yes is selected all logged events will be erased When Log is Full Use this item to choose options for reactions to a full Smbios Event Log The options include Do Nothing and Erase Immediat...

Страница 67: ...1 English entries which utilize a multiple event counter The value ranges from 0 to 99 minutes View Smbios Event Log Press Enter to view the Smbios Event Log records All values changed here do not tak...

Страница 68: ...es and Exit When you select this option the following message Discard changes and exit setup will pop out Press ESC key or select Yes to exit the UEFI SETUP UTILITY without saving any changes Discard...

Страница 69: ...ard s features 4 2 1 Running The Support CD To begin using the support CD insert the CD into your CD ROM drive The CD automatically displays the Main Menu if AUTORUN is enabled in your computer If the...

Страница 70: ...t settings 3 Check the settings of the 115V 230V switch on the power supply 4 Verify if the battery on the motherboard provides 3VDC Install a new battery if it does not If there is no video 1 Try rep...

Страница 71: ...s 1 Verify if the battery on the motherboard provides 3VDC Install a new battery if it does not 2 Confirm whether your power supply provides adaquate and stable power Other problems 1 Try searching ke...

Страница 72: ...f your invoice marked with the date of purchase is required By calling your vendor or going to our RMA website http event asrockrack com tsd asp you may obtain a Returned Merchandise Authorization RMA...

Отзывы: