background image

2

E   N   G   L   I   S   H

C E X - 7 0

1. GENERAL

1.1 

 

INTRODUCTION

This manual was prepared with the aim of making the installation and management of your system as simple as 

possible.

By reading and applying the suggestions of this manual, you can achieve the best performance of the purchased 

product.

We would like to thank you for choosing to purchase one of our products.

Read this file carefully before performing any operation on the unit.

The unit must not be installed, nor must any operation be performed on it, without firstly reading and understanding 

the entirety of this manual. In particular it is necessary to adopt all of the precautions listed in the manual.

The documentation provided with the unit must be delivered to the system manager for safe keeping (at least 10 

years) for future assistance, maintenance and repairs.

Unit installation must take into account the strictly technical needs for good operation, as well as any local 

legislation in force and specific requirements.

Make sure that when the unit is delivered there are no evident signs of damage caused by transport. If there is, 

state this on the delivery note.

This manual reflects the state of the technical standards at the time of sale and cannot be considered inadequate 

if updated at a later date based on new experiences. The Manufacturer reserves the right to update production and 

the manuals without being required to update previous ones, except in exceptional cases.

Contact the Manufacturer’s Sales Office to receive further information or updates on/to the technical documentation 

and for any suggestions for improvement to this manual. All suggestions shall be strictly vetted.

1.2  FUNDAMENTAL SAFETY RULES

This instruction is an integral part of the manual of the device that the KIT is installed on. Refer to said 

manual for the GENERAL WARNINGS and for the FUNDAMENTAL SAFETY RULES. Installation must be 

carried out by qualified personnel equipped with the necessary PERSONAL PROTECTIVE EQUIPMENT.

compliance with local regulations.

Содержание CEX-70

Страница 1: ...I N S T A L L A T I O N U S E A N D M A I N T E N A N C E M A N U A L CEX 70 ...

Страница 2: ...good operation as well as any local legislation in force and specific requirements Make sure that when the unit is delivered there are no evident signs of damage caused by transport If there is state this on the delivery note This manual reflects the state of the technical standards at the time of sale and cannot be considered inadequate if updated at a later date based on new experiences The Manu...

Страница 3: ...CABINET KIT CEX 70 code AP20375 INSTALLATION WITH RECESSED CABINET KIT AIR OUTLET PLENUM CABINET KIT CEX 70 code AP20375 GEX 70 grids code AP20376 SIDE VIEW SIDE VIEW FRONT VIEW FRONT VIEW FRONT VIEW PASSAGES FOR OUTDOOR and EXHAUST AIR PASSAGES FOR OUTDOOR and EXHAUST AIR BOTTOM VIEW 6 6 FITTINGS DN 75 90 BOTTOM VIEW 6 6 FITTINGS DN 75 90 FRONT VIEW ...

Страница 4: ...mm 16 16 Outdoor air exhaust diameter DN Ø 160 160 Supply exhaust diameter DN Ø 6 6 x 75mm 6 6 x 75mm Condensate discharge diameter DN S mm 20 20 Cable diameter DN S mm 16 16 Weight Kg 25 37 2 2 UNIT POSITIONING CABINET KIT POSITIONING For cabinet kit positioning prepare a suitable hole in the wall to house the cabinet kit position the cabinet kit inside the wall ...

Страница 5: ...ible to secure the cabinet kit by the 4 rear holes and based on the construction materials using suitable screws and plugs secure the cabinet kit by the 4 anchoring brackets on the two sides In this case after positioning it needs to be secured with cement mortar and suitable products ...

Страница 6: ...urn The body allows 6 6 corrugated pipes to pass through the bottom where the bottom insulation is installed On the other hand the starting fittings are installed at the bottom of the plenum inside the body Proceed with installation of the starting fitting in the desired position Carefully cut the insulation with a cutter or mill with a diameter of 80mm Then put the pipe in place and fit it to the...

Страница 7: ...the outdoor air kit to be connected by DN160 pipes to position the outdoor air kit at the chosen height 2 The cabinet kit directly becomes the outdoor air exhaust and intake point through the outdoor air kit accessory positioned directly above the cabinet kit The air is ejected from the top right part while it is drawn in from outdoors on the top left part Outdoor and exhaust air configurations wi...

Страница 8: ...ust air configurations with ducts CONNECTION WITH OUTDOOR AIR KIT For installation with the outdoor air kit there are two installation options The first is through chosen nipples and pipes with diam of 160mm with remote control of the outdoor air kit at a height on the wall that may be chosen by the installer EXHAUST SUPPLY EXTRACTION OUTDOOR AIR EXHAUST SUPPLY EXTRACTION OUTDOOR AIR ...

Страница 9: ...h cabinet kit and plenum and place the plenum on top of the cabinet kit Then secure with the provided holes and screws OUTDOOR AND EXHAUST AIR PIPE CONNECTION For installation with outdoor and exhaust air pipes start from the two connections on the outside of the body through the nipple and chosen pipes with diam of 160mm EXHAUST EXHAUST SUPPLY EXTRACTION OUTDOOR AIR OUTDOOR AIR ...

Страница 10: ...e entrances have been provided on both sides with pre shearing of the cabinet kit for the set up of electrical cables and condensation discharges For electrical cables there are two holes provided for inlet with dn20mm corrugated sheath There is a Dn24mm inlet provided for the condensation discharge ELECTRICAL CABLE INPUT CONDENSATION DISCHARGE ...

Страница 11: ... ...

Страница 12: ...FANTINI COSMI S p A Via Dell Osio 6 20090 Caleppio di Settala Milan Italy Tel 39 02 956821 Fax 39 02 95307006 E mail info aspira it supportotecnico aspira it 07 2020 www aspira it ...

Отзывы: