INST

ALLA

TION, USE AND MAINTENANCE MANUAL

CEX-70

Содержание CEX-70

Страница 1: ...I N S T A L L A T I O N U S E A N D M A I N T E N A N C E M A N U A L CEX 70 ...

Страница 2: ...good operation as well as any local legislation in force and specific requirements Make sure that when the unit is delivered there are no evident signs of damage caused by transport If there is state this on the delivery note This manual reflects the state of the technical standards at the time of sale and cannot be considered inadequate if updated at a later date based on new experiences The Manu...

Страница 3: ...CABINET KIT CEX 70 code AP20375 INSTALLATION WITH RECESSED CABINET KIT AIR OUTLET PLENUM CABINET KIT CEX 70 code AP20375 GEX 70 grids code AP20376 SIDE VIEW SIDE VIEW FRONT VIEW FRONT VIEW FRONT VIEW PASSAGES FOR OUTDOOR and EXHAUST AIR PASSAGES FOR OUTDOOR and EXHAUST AIR BOTTOM VIEW 6 6 FITTINGS DN 75 90 BOTTOM VIEW 6 6 FITTINGS DN 75 90 FRONT VIEW ...

Страница 4: ...mm 16 16 Outdoor air exhaust diameter DN Ø 160 160 Supply exhaust diameter DN Ø 6 6 x 75mm 6 6 x 75mm Condensate discharge diameter DN S mm 20 20 Cable diameter DN S mm 16 16 Weight Kg 25 37 2 2 UNIT POSITIONING CABINET KIT POSITIONING For cabinet kit positioning prepare a suitable hole in the wall to house the cabinet kit position the cabinet kit inside the wall ...

Страница 5: ...ible to secure the cabinet kit by the 4 rear holes and based on the construction materials using suitable screws and plugs secure the cabinet kit by the 4 anchoring brackets on the two sides In this case after positioning it needs to be secured with cement mortar and suitable products ...

Страница 6: ...urn The body allows 6 6 corrugated pipes to pass through the bottom where the bottom insulation is installed On the other hand the starting fittings are installed at the bottom of the plenum inside the body Proceed with installation of the starting fitting in the desired position Carefully cut the insulation with a cutter or mill with a diameter of 80mm Then put the pipe in place and fit it to the...

Страница 7: ...the outdoor air kit to be connected by DN160 pipes to position the outdoor air kit at the chosen height 2 The cabinet kit directly becomes the outdoor air exhaust and intake point through the outdoor air kit accessory positioned directly above the cabinet kit The air is ejected from the top right part while it is drawn in from outdoors on the top left part Outdoor and exhaust air configurations wi...

Страница 8: ...ust air configurations with ducts CONNECTION WITH OUTDOOR AIR KIT For installation with the outdoor air kit there are two installation options The first is through chosen nipples and pipes with diam of 160mm with remote control of the outdoor air kit at a height on the wall that may be chosen by the installer EXHAUST SUPPLY EXTRACTION OUTDOOR AIR EXHAUST SUPPLY EXTRACTION OUTDOOR AIR ...

Страница 9: ...h cabinet kit and plenum and place the plenum on top of the cabinet kit Then secure with the provided holes and screws OUTDOOR AND EXHAUST AIR PIPE CONNECTION For installation with outdoor and exhaust air pipes start from the two connections on the outside of the body through the nipple and chosen pipes with diam of 160mm EXHAUST EXHAUST SUPPLY EXTRACTION OUTDOOR AIR OUTDOOR AIR ...

Страница 10: ...e entrances have been provided on both sides with pre shearing of the cabinet kit for the set up of electrical cables and condensation discharges For electrical cables there are two holes provided for inlet with dn20mm corrugated sheath There is a Dn24mm inlet provided for the condensation discharge ELECTRICAL CABLE INPUT CONDENSATION DISCHARGE ...

Страница 11: ... ...

Страница 12: ...FANTINI COSMI S p A Via Dell Osio 6 20090 Caleppio di Settala Milan Italy Tel 39 02 956821 Fax 39 02 95307006 E mail info aspira it supportotecnico aspira it 07 2020 www aspira it ...