INST

ALLA

TION, USE AND MAINTENANCE MANUAL

ASPIRCOMF

ORT PRO 

X 380

V

Содержание ASPIRCOMFORT PRO X 380V

Страница 1: ...I N S T A L L A T I O N U S E A N D M A I N T E N A N C E M A N U A L ASPIRCOMFORT PRO X 380V ...

Страница 2: ...If there is state this on the delivery note This manual reflects the state of the technical standards at the time of sale and cannot be considered inadequate if updated at a later date based on new experiences The Manufacturer reserves the right to update production and the manuals without being required to update previous ones except in exceptional cases ContacttheManufacturer sSalesOfficetorecei...

Страница 3: ...ctive machines all machines must be earthed according to the regulations in force in the various countries Do not release R410Anell into the atmosphere R410A is a fluorinated greenhouse gas referred to in the Kyoto protocol with a global warming potential GWP of 1975 1 3 SYMBOLS The symbols used in the following file quickly provide information necessary for the correct use of the unit Safety symb...

Страница 4: ...evices Always install an earth leakage circuit breaker failure to install this device could cause electric shock For the connection use a sufficiently long cable to cover the entire distance without any connection do not use extensions and do not apply other loads on the power supply rather always use a dedicated power supply circuit When the electrical cables are connected make sure that the cabl...

Страница 5: ...kes machine identification and ordering spare parts very difficult and therefore all future maintenance 1 8 CONSTRUCTION FEATURES The ASPIRCOMFORT PRO X 380V units are designed for the renewal of the air in rooms The easy installation through two holes diam 160 mm and the high flow rate of fresh air allows the application in situations such as residential buildings schools clinics offices and all ...

Страница 6: ...ntity than that taken away by the ventilation for 90 of the unit s operation FILTRATION There are 2 ePM1 filters on the extract air and the supply air the filter on the supply air is placed after the coil to completely filter out any impurities in the supply air On the outdoor air there is a Coarse pre filter that protects the cleanliness of the unit STRUCTURE Self supporting sheet metal frame Sel...

Страница 7: ...ding details on the extent of the damage on the delivery note providing photographic evidence of the alleged damage and notifying the shipping company of any alleged damage by registered mail with return receipt The manufacturer will not be held liable for damage caused by transport even if he himself did the shipping It is necessary to be very careful when handling the unit during unloading and p...

Страница 8: ...PIRCOMFORT PRO X 380V 1 9 MAIN COMPONENTS OF THE UNIT 1 Compressor 2 Intake fan 3 Exhaust fan 4 Input coil 5 Exhaust coil 6 Electrical panel 7 Display 8 Outdoor air pre filter 9 Epm1 filters 10 UVC lamp AP20384 accessory ...

Страница 9: ...ve the following requirements Respect the spaces indicated in the figure The wall on which the unit is to be fixed must be sturdy and suitable to support its weight It must be possible to leave space around the unit for maintenance There must be no obstacles to the free circulation of air in the upper intake area curtains plants furniture or in the front air outlet area this could cause turbulence...

Страница 10: ...t using appropriate equipment that facilitates your work and avoids excessive damage or disturbance to your customer The best tools for drilling large diameter holes in walls are special drills called core drills with high torque and adjustable rotation speed depending on the diameter of the hole to be drilled and the material To prevent the spread of large quantities of dust and debris in the env...

Страница 11: ...r anchoring the wall mounting bracket as indicated on the drilling template The greatest weight of the appliance is on the right hand side so it is preferable to secure a firmer fixing on this side The 6 dowels supplied require a hole diameter of 8 mm In any case a careful examination of the characteristics and consistency of the wall is necessary to determine the number of fixings to be made and ...

Страница 12: ...towards you Direct electrical connection by disconnecting the power cable with plug and fixing the condensate discharge must be carried out with the appliance away from the wall by means of a wooden wedge or similar object At the end of the work carefully check that no cracks remain behind the back of the unit especially in the area of the air inlet and outlet ducts To increase installation safety...

Страница 13: ...n water The hole for the condensate pipe must always have an outward slope The exact position of the pipe opening in relation to the machine is defined on the drilling template Take care in this case that the water expelled does not cause damage or inconvenience to property or persons During the winter period this water can cause ice sheets to form outside When connecting the condensate discharge ...

Страница 14: ...14 E N G L I S H ASPIRCOMFORT PRO X 380V 1 Wall section 2 Insulation 3 Emergency drain 4 Condensate discharge pipe Condensate discharge connection ...

Страница 15: ...tings of different Ø and one rectangular front opening based on the size To correctly connect the air ducts refer to the following diagram and stickers on the unit Table of unit aeraulic connection diameters Codes AP20069 Ø Outdoor air mm 160 mm Ø Exhaust mm AIRFLOW CONFIGURATIONS Rear view SUPPLY OUTDOOR AIR EXHAUST EXTRACTION ...

Страница 16: ...tion C and check that the closing mechanism works pull the chains by tensioning the springs use a wire cutter to cut off the excess chain links fix the chain hook to the wall B Use only the grills supplied or grills with the same characteristics The dampers must be positioned with the flap vertical The dampers are different A distinction must be made between the one on the inlet and the one on the...

Страница 17: ... electrical power of the installed unit and that they take into account the start up currents of the compressor in addition to the maximum achievable load The relative data is stated on the attached wiring diagram and on the unit s rating plate It is forbidden to enter the unit with electrical cables except where specified in this file Use duly sized electrical cables and conductors that comply wi...

Страница 18: ... and with a schuko plug for connection to the mains The electrical cable entry is located at the bottom of the unit where the cable holes are located The connections are inside the electrical compartment located in the lower left hand corner where the terminal block with power supply and ON OFF control is clearly visible 1 Cable entry 2 Terminal block ...

Страница 19: ...pply may be used for the remote control Spent batteries may only be disposed of at collection points set up by Local Authorities for this type of waste To insert the battery open the snap on battery door at the bottom of the remote control The battery must be inserted carefully observing polarity Close the snap on door once the battery is inserted ...

Страница 20: ...20 E N G L I S H ASPIRCOMFORT PRO X 380V 4 4 WIRING DIAGRAM ...

Страница 21: ... to terminals N L PE HT EXTERNAL HEATER It provides for the connection of the additional electrical resistance Accessory to be inserted on the air supply duct CP ON OFF REMOTE Provides an external connection to enable the unit as a presence or window contact Comes with a bridge supplied REMOTE ON OFF EXTERNAL HEATER UNIT POWER SUPPLY ...

Страница 22: ...The remote control supplied with the appliance has been designed to be extremely sturdy and functional but must be handled with care Avoid leaving it exposed to rain spill liquids on its keyboard or drop it in water subjecting it to heavy impacts or dropping it on hard surfaces leaving it exposed to sunlight Wifi machine panel Remote control Remote control button Touch screen display button KEY DI...

Страница 23: ...ERATURE SET MODIFICATION On the display there are buttons for selecting the desired temperature of the unit Whenever the set temperature is changed the display will also show the change in set point required FAN SPEED MODIFICATION By pressing this button sequentially the power supplied by the appliance can be set to 5 settings Minimum Medium Maximum Dual Power and Automatic The higher the power se...

Страница 24: ...set is not altered any further and after a further 6 hours the appliance is placed in stand by This function is not available for dehumidification only ventilation only and economic automatic operation and can be overridden at any time ideally when waking up by pressing the button again If the timer function is set at the same time the device will switch off after the set time has elapsed DEHUMIDI...

Страница 25: ...owed by setting the number of hours from 1 to 24 after which the unit will start up Subsequent pressing of the key for confirmation 5 2 AIR QUALITY SENSOR OPERATION The unit provides for the operation of the fans according to the selected speed and the internal logic linked to the air quality value detected for each speed if the air quality is not optimal the fans increase the flow rates in order ...

Страница 26: ...eriodically clean them do the following cut off the power to the unit remove the air intake grille 2 remove the 2 dirty filters by pulling them out at the front remove the air outlet grille 1 remove the 2 dirty filters by pulling them out of the top gently insert the new ones close the air intake and outlet grilles If the conditions of the filters allow it it is possible to proceed with cleaning t...

Страница 27: ...r proceed as follows cut off the power to the unit remove the air outlet grille remove the filter If the conditions of the filters allow it it is possible to proceed with cleaning them using a vacuum cleaner or low pressure compressor close the filter cover again ensuring that all screws are tightened ...

Страница 28: ...panel by sliding it upwards Remove the two front covers to access the external air section Above the inlet fan the lamp and its lamp holder will be visible To remove the lamp rotate the lamp in relation to the lamp holder and pull it out in the opposite direction to the lamp holder Carry out the operation carefully and gently Replace the lamp ensuring that it is properly coupled to its holder Repl...

Страница 29: ...ly connector black on the side of the unit Poor or no air flow rate The rooms remain humid Clogged filters Change the filters Clogged exchanger Clean the exchanger Frozen exchanger Take the exchanger to a warm place and wait for it to defrost do not heat with direct sources of heat Dirty fan Clean the fan Clogged fan ducts Clean the fan ducts Outdoor temperature below 0 C The unit might be in anti...

Страница 30: ...n tray Make sure that the unit is perfectly level Check that the condensation discharge connections are not clogged The appliance does not switch on No power supply Check whether there is voltage in the mains by switching on a light bulb in the house for example Check that the exclusive thermomagnetic switch protecting the appliance has not tripped if so reset it If the problem recurs contact the ...

Страница 31: ...ification and Heating functions can be activated regularly E4 Faulty OPT external battery probe The Cooling Dehumidification and Heating functions can be activated regularly The control runs defrosting cycles at fixed times E5 Faulty internal fan motor No operation of the device can be activated E6 Faulty external motor fan No operation of the device can be activated E7 Lack of communication with ...

Страница 32: ...FANTINI COSMI S p A Via Dell Osio 6 20049 Caleppio di Settala Milan Italy Tel 39 02 956821 Fax 39 02 95307006 E mail info aspira it supportotecnico aspira it EN 5680003A 11 2021 www fantinicosmi it ...