FCC PART 15 COMPLIANCE INFORMATION

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 

of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the 

equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency 

energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to 

radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which 

case the user will be required to correct the interference at his own expense

FCC PART 68 COMPLIANCE INFORMATION

This equipment complies with Part 68 of the FCC rules.  Located on the equipment is a label that contains, among 

other information, the ACTA registration number and ringer equivalence number (REN.) If requested, this information 

must be provided to the telephone company.
The REN is used to determine the quantity of devices which may be connected to the telephone line.  Excessive 

REN’s on the telephone line may result in the devices not ringing in response to an incoming call.  In most, but not all 

areas, the sum of the REN’s should not exceed five (5.0).  To be certain of the number of devices that may be con-

nected to the line, as determined by the total REN’s contact the telephone company to determine the maximum REN 

for the calling area.
This equipment cannot be used on the telephone company-provided coin service. Connection to Party Line Service is 

subject to State Tariffs.
If this equipment causes harm to the telephone network, the telephone company will notify you in advance that tempo-

rary discontinuance of service may be required.  If advance notice isn’t practical, the telephone company will notify the 

customer as soon as possible.  Also, you will be advised of your right the file a complaint with the FCC if you believe it 

is necessary.
The telephone company may make changes in its facilities, equipment, operations, or procedures that could affect the 

operation of the equipment.  If this happens, the telephone company will provide advance notice in order for you to 

make the necessary modifications in order to maintain uninterrupted service.
If trouble is experienced with this equipment, please contact:   
Lectrosonics, Inc. 

581 Laser Rd. Rio Rancho, NM 87124 

Tel: 505-892-4501 

Fax: 505-892-6243 
If the trouble is causing harm to the telephone network, the telephone company may request you to remove the equip-

ment from the network until the problem is resolved.
This equipment uses the following USOC jacks: RJ11C
It is recommended that the customer install an AC surge arrester in the AC outlet to which this device is connected.  

This is to avoid damaging the equipment caused by local lightening strikes and other electrical surges.

INDUSTRY CANADA NOTICE

This product meets the applicable Industry Canada technical specifications/Le présent materiel est conforme aux 

specifications techniques applicables d’Industrie Canada. 
The Ringer Equivalence Number is an indication of the maximum number of devices allowed to be connected to a 

telephone interface. 
The termination on an interface may consist of any combination of devices subject only to the requirement that the 

sum of the RENs of all the devices does not exceed five.
L’indice d’équivalence de la sonnerie (IES) sert à indiquer le nombre maximal de terminaux qui peuvent être raccor-

dés à une interface téléphonique. 
La terminaison d’une interface peut consister en une combinaison quelconque de dispositifs, à la seule condition que 

la somme d’indices d’équivalence de la sonnerie de tous les dispositifs n’excède pas 5.”

Содержание SPNTWB

Страница 1: ...NTWB Trio Conference Interface Wideband Bridging INSTALLATION and STARTUP GUIDE Software and Hardware Installation and Setup IMPORTANT See page 14 for Minimum Setup Requirements Visit the ASPEN Suppor...

Страница 2: ...SPNTWB LECTROSONICS INC 2...

Страница 3: ...ed use caution when moving the cart appa ratus combination to avoid injury from tip over 13 Unplug this apparatus during lightning storms or when unused for long periods of time Important Safety Instr...

Страница 4: ...rease even with brief signal peaks from the far end and convergence will never be lost with any type of signal or in double talk situations Signals from the far ends of the conference are routed to th...

Страница 5: ...agram 10 Crestron and AMX Port Wiring Diagram 10 Cabling Of Stacked Units 10 Software Installation 11 Refer to the Help Files 11 Creating an ASPEN Installer Disk 11 Software and Firmware Updates 12 Fi...

Страница 6: ...dure to update the firmware in the processor See the section on Firmware Update Pro cedure for details Status LEDs Comm LED blinks to indicate USB RS 232 and ethernet communication Alert LED blinks to...

Страница 7: ...ed differential type Channels 1 through 8 on each board are nominal line level outputs with gain adjustment from 60 to 20 dB Channels 9 through 12 on each board are also line level outputs with switch...

Страница 8: ...damage to the front panel s finish when tightening the mounting screws All ASPEN processors have internal switching power supplies that can tolerate voltages ranging from 100 to 240 VAC Use an approve...

Страница 9: ...imum usable voltage for the pro grammable outputs is 40 V and they will safely conduct up to 100 mA DC continuous Both LEDs and 5V relay coils can be powered by the 5 V DC pins on the programmable inp...

Страница 10: ...connector Male connector Female jack Male jack Cabling Of Stacked Units In a stacked configuration ASPEN processors must be interconnected as shown here Each Slave unit in a stack gathers data and au...

Страница 11: ...lation It is best to check all three boxes so the the USB driver Control Panel and Help utility will all be installed Follow the on screen prompts to complete the installa tion On the last screen clic...

Страница 12: ...on your local drive The result ing filename will indicate the model number and ver sion followed by the extension update Firmware Update Procedure Update Procedure 1 It is assumed that the USB driver...

Страница 13: ...bernation or sleep mode during the update process NOTE If the procedure is interrupted see the next section on recovery 9 When the update is complete click Finish to exit the Update Wizard 10 Cycle th...

Страница 14: ...for several minutes It is good practice to turn all units on simul taneously or turn on Slave units before turning on the Master unit The available processors will appear in a stack in the control pan...

Страница 15: ...encing settings define the behavior of the Codec and Telephone inter faces Conferencing screen Telephone Interface setup selected Select Telephone CODEC and AEC setup screens Acoustic Echo Canceller C...

Страница 16: ...entire signal chain Double left click and single right click actions open setup and status dialogue boxes The view may be panned or zoomed as needed Hold down the CTRL key and press to zoom in Hold d...

Страница 17: ...llation and Startup Guide Rio Rancho NM 17 Unused crosspoint columns can be hidden and unhid den by highlighting a range of Mixes across the top followed by a right click and selection of the desired...

Страница 18: ...y Mute panic button Pressing the UP and DOWN buttons together will mute all outputs to remedy situations such as runaway feedback Restore Default Settings Master Reset Hold in the LEFT and UP buttons...

Страница 19: ...LED will light up to indicate power ON and a ready status Navigating Individual Settings The following example illustrates the structure of the LCD screens used to set up the processor Select a catego...

Страница 20: ...p EQ Filter Setup Output Group Setup RPC Rear Panel Control Prog Input Setup Virt Prog Input Setup slave unit triggers from Prog Input activity on Master unit Prog Output Setup RP Input Gain Setup RP...

Страница 21: ...t take effect until the processor power is cycled off and back on again Web Browser Interface A simple interface is provided to communicate directly with the processor through a network using the HTTP...

Страница 22: ...turning Units for Repair For timely service please follow the steps below A DO NOT return equipment to the factory for repair without first contacting us by e mail or by phone We need to know the natu...

Страница 23: ...scontinuance of service may be required If advance notice isn t practical the telephone company will notify the customer as soon as possible Also you will be advised of your right the file a complaint...

Страница 24: ...rosonics Inc will pay for the cost of returning your equipment to you This warranty applies only to items returned to Lectrosonics Inc or an authorized dealer shipping costs prepaid within three years...