background image

SENTIR EDGE KS4 PRO ASSEMBLY

 

Assembly instructions KS4 PRO

1. Cutting the safety-contact-edge

The safety-contact-

profile 

is cut 24 mm shorter than the final 

length dimension to allow for the length of the end caps on each 
end. 

Make sure that the cut surfaces are rectangular and clean, so 

the cut should be made starting at the chamber side of the safety 
edge. 

 Only 

Special scissors or table lever blade offered by ASO 

should be used for this purpose.

2. Preparing end caps
a) Water drain plugs

For installations in contact with water, it is necessary to remove 

both 

water drain plugs

 (semi- round marks)

. For vertical 

mounting, remove the two markings in the lower end cap

 (nearest 

the floor)

, for horizontal mounting, remove the two markings in 

both end caps.

b) Notch for the sealing lip

When  assembling  safety-contact-edges  with  sealing  lips,  the  end 
caps  have  to  be  notched  where  indicated  to  allow  for  the  sealing 
lip(s). 

c) Connection cable

Choose desired cable exit of end cap. If necessary, 

push

 through 

the marks

 with a small screwdriver or tool

.

L

L - 2

4

.

.

ü

X

X

Endcap

Lock cap

 

 

Fixation clip

 

 

Plug with resistor

 

Plug with connection cable

1