SENTIR EDGE KS4 PRO ASSEMBLY
Assembly instructions KS4 PRO
1. Cutting the safety-contact-edge
The safety-contact-
profile
is cut 24 mm shorter than the final
length dimension to allow for the length of the end caps on each
end.
Make sure that the cut surfaces are rectangular and clean, so
the cut should be made starting at the chamber side of the safety
edge.
Only
Special scissors or table lever blade offered by ASO
should be used for this purpose.
2. Preparing end caps
a) Water drain plugs
For installations in contact with water, it is necessary to remove
both
water drain plugs
(semi- round marks)
. For vertical
mounting, remove the two markings in the lower end cap
(nearest
the floor)
, for horizontal mounting, remove the two markings in
both end caps.
b) Notch for the sealing lip
When assembling safety-contact-edges with sealing lips, the end
caps have to be notched where indicated to allow for the sealing
lip(s).
c) Connection cable
Choose desired cable exit of end cap. If necessary,
push
through
the marks
with a small screwdriver or tool
.
L
L - 2
4
.
.
ü
X
X
Endcap
Lock cap
Fixation clip
Plug with resistor
Plug with connection cable
1