12. Technical specifi cati ons
Supply voltage
Mains voltage:
U
mains
230 V AC 50/60 Hz
Low voltage:
U
E
24 V AC/DC ±10 %
Power consumpti on
P
max
3 VA
Dimensions
(WxHxD)
95 x 71 x 35 mm
Protecti on class
IP00
Weight
220 g
Temperature range
-20°C to +55°C
Connecti on cable cross-secti on
single- or fi ne-stranded cable 0,75-1,5 mm
2
Certi fi cati ons
(In accordance with ELMON inducti ve 74-312)
DIN EN ISO 13849-1:2015 Category 3 PL e
MTTFd 170 years, DC 91%
Electronics
MTTFd 1616 years, DC 99 %
Electromechanics
B10d 1000000
MTTFd 190 years (Nop 52560)
Safety device acc. to DIN EN 12978
All voltages connected to the switching unit must
be safely isolated!
English
Inducti ve signal transmission system
11. Taking out of service and disposal
The products manufactured by ASO are intended solely for commercial use (B2B). At the end of use, the
products are to be disposed of according to all local, regional and nati onal regulati ons. Products can also be
returned to ASO, which will then dispose of them properly.
Test report no.:
3525 3024
EC type-examinati on no.:
44 205 13 031832
Stati onary
contact edge
Travelling
contact edge
nominal value
R
nom
= 8,2 kΩ
= 8,2 kΩ
upper switching point
R
AO
> 12 kΩ
> 20 kΩ
lower switching point
R
AU
< 5 kΩ
< 2,5 kΩ
Terminal resistance of the safety contact edges
Nominal current DC
3 A
30 V DC
Nominal current AC
3 A
30 V AC
Mech. life-ti me
>10
6
actuati ons
Relay stages
Stati onary
contact edge
Travelling
contact edge
Switching off delay (response ti me)
< 10 ms
< 30 ms
Switching on delay
500 ms (Power on 700 ms)
Safety relay switching ti mes
35
95