Installation
311139B
5
Installation
Grounding and Electric
Requirements
The sprayer requires
a 120V AC, 60 Hz, 15A circuit
with a grounding receptacle. Never use an outlet that is
not grounded or an adapter.
Do not use the sprayer if the electrical cord has a dam-
aged ground prong. Only use an extension cord with an
undamaged, 3-prong, plug.
Recommended extension cords
for use with this
sprayer:
•
25 ft (7.6 m) 18 AWG
•
50 ft (15.2 m) 16 AWG
•
100 ft (30.5 m) 14 AWG
•
150 ft (45.7 m) 12 AWG
Spray gun:
ground through connection to a properly
grounded fluid hose and pump.
Fluid supply container:
follow local code.
Solvent pails used when flushing:
follow local code.
Use only conductive metal pails, placed on a grounded
surface such as concrete. Do not place the pail on a
nonconductive surface, such as paper or cardboard,
which interrupts grounding continuity.
Grounding the metal pail:
connect a ground wire to the
pail by clamping one end to pail and other end to ground
such as a water pipe.
Maintaining grounding continuity when flushing or
relieving pressure:
hold metal part of the spray gun
firmly to the side of a grounded metal pail, then trigger
the gun.
Thermal Overload
Motor has a thermal overload switch to shut itself down
if overheated.
Smaller gauge or longer extension cords may
reduce sprayer performance.
WLD
WLD
To reduce risk of injury from motor starting unexpect-
edly when it cools, always turn power switch OFF if
motor shuts down.
WLD