ASM GmbH
MAN-PD-INC-E-16 13
www.asm-sensor.com
PRODIS
®
-INC
Instruction Manual
Explanation and
operation of the
functions
(continuation)
Parameter settings
The Parameter settings are effected in a programming menu.
+
Activate programming mode
,
Change the parameter by decimal steps
+
Reset activated parameter
+
Change the sign of signed parameters
Store in non-volatile memory
Proceed and return to normal mode
New settings become effective immediately
Submenus
Parameter
Display
Value range
Factory
setting
Decimal point
dp
1 of 5, AUS (off)
AUS (off)
Z signal active/inactive
rEF
1 / 0
0
Reset button
active/inactive
nuL
1 / 0
1
Automatic relative
measurement reset
CHnul
1 / 0
1
Multiplier
ZAEHL
0 ... +999999
1
Divisor
nEnnEr
0 ... +999999
1
Counting direction
drEh L/r
left / right
left
T signal
t
oFF/CS/Hn/AF/tl/
brEF/Ctr3/Ctr4
oFF
Last value memory
ISt
1 / 0
0
Display brightness
db
1 ... 15
15
Transmission rate
bA
4.8, 9.6 ... 115.2
9.6
Relative measurement
mode
Flashing
decimal point
0
Reset
Offset
oFFSEt
-999999 ... +999999
0
+
Limit value
rELx
+/- 999.999
+999.999
Hysteresis
Hµ rELx
+/- 999.999
1
Operating direction
rx
oEF, SCH
SCH (no)
Measurement mode
rx
HAU / CHA
HAU (normal)
Reset to factory
default value
000000 for
2 s
* Disconnect device from excitation, wait 5 seconds, press and together and hold.
Connect excitation, the display shows “000000”, then release + .
+
+
+ Power on*
+
SUNSTAR传感与控制 http://www.sensor-ic.com/ TEL:0755-83376549 FAX:0755-83376182 E-MAIL:[email protected]
SUNSTAR自动化 http://www.sensor-ic.com/ TEL: 0755-83376489 FAX:0755-83376182 E-MAIL:[email protected]