background image

Installation and operation manual  

EN

posi

tape

®

 

WBT Series

Combined displacement and inclination sensors

Please read carefully before installation and operation!

Содержание positape WBT Series

Страница 1: ...Installation and operation manual EN positape WBT Series Combined displacement and inclination sensors Please read carefully before installation and operation ...

Страница 2: ... ASM Automation Sensorik Messtechnik GmbH 2020 All rights reserved Am Bleichbach 18 24 85452 Moosinning Germany ...

Страница 3: ...al safety instructions 5 1 3 Intended use 6 2 Transport and storage 6 3 Installation and initial operation 7 3 1 Mechanical installation 7 3 2 Electrical connection 12 3 3 Operating temperature 14 4 Maintenance and disposal 15 4 1 Maintenance and repair 15 4 2 Disposal 15 5 Output specification 16 5 1 Measurement signal and range 16 5 2 Digital interface CANopen 17 ...

Страница 4: ...Personal Injury or Death Indicates a situation that can result in serious personal injury or death if not properly avoided WARNING Risk of Personal Injury or Death Indicates a situation that can result in moderate personal injury or death if not properly avoided WARNING Risk of Personal Injury Indicates a situation that can result in minor personal injury if not properly avoided WARNING Risk of Pr...

Страница 5: ...uded by additional safety measures In safety relevant applications additional facilities shall be provided for maintaining safety and preventing damage Check whether the protection class of the sensor is suitable for the application Risk of crushing and cutting injury due to pre tensioned spring being released from housing when opened Do not open the sensor Risk of cutting injury due to uncontroll...

Страница 6: ...and all maintenance and service work must be carried out The data sheet of the respective sensor is part of this instruction manual If not available it may be requested by stating the respective model number The sensor must not be improperly mounted operated or serviced In addition operation of the sensor in faulty condition is prohibited Pos 15 Bedienungsanl eitungen Positape W B_Tr ansport und L...

Страница 7: ...he tape outlet Screw the sensor onto a flat surface or provide a three point mounting This avoids distortion and damage to the sensor Fitting the sensor Depending upon the sensor model holes in the base plate or threads in the sensor housing enable attachment of the sensor Dimensions required are listed in the data sheet and the catalog Tape attachment device For fastening the tape clip the 5 mm d...

Страница 8: ...vice life of sensor and causes error in measurement Warranty will not be granted for damage caused by misalignment correct incorrect If tape travel axial to the tape outlet is not possible a tape guide wheel must be used in order to divert the tape The deflection is possible only in one axis on the flat side Pulley wheels with the diameter of 15 mm are recommended see chapter Accessories in the ca...

Страница 9: ... Model Screw Screw material Torque Nm WBT61 oval hole M5 A2 2 0 WBT85 M6 A2 4 0 WBT85 oval hole M6 A2 3 0 The clamps are mounted ex factory Fixing is possible laterally or on the bottom side of the clamp Pos 21 Bedienungsanl eitungen Positape W BT21_Befestigung 7 mod_1530273919863_78 docx 57116 1 Sensors with holes in the base plate Model Screw Screw material Torque Nm WBT21 M5 A2 2 5 WBT21 M6 A2 ...

Страница 10: ... 8 mod_1569317172828_78 docx 67992 1 Mounting options for inclination measurement for WBT21 sensors The mounting option can be set by the user via software Sensor position as shown equals 0 WBT21 Mounting option 1 Mounting option 2 Mounting option 3 Output signal Pos 24 Bedienungsanl eitungen Positape Kennlinie_WBT61_85 8 mod_1569316673928_78 docx 67986 1 ...

Страница 11: ...m 11 Mounting options for inclination measurement for WBT61 WBT85 sensors The mounting option can be set by the user via software Sensor position as shown equals 0 WBT61 WBT85 Mounting option 1 Mounting option 2 Mounting option 3 Output signal Pos 25 Sei tenum bruch 0 mod_1353584168894_0 docx 336 1 ...

Страница 12: ...rotection class of the mating connector is valid Avoid crossing the dew point Cable outputs must be installed in such a way that no moisture can get into the cable The protection class of sensors with connector output is valid only if the electrical plug is connected Damage of the sensor cable due to mechanical stress Do not twist the M12 connector insert It is important that the knurled nuts on t...

Страница 13: ...52835 1 Installation of the sensor supply cable incorrect correct Admissible bending radius of the cable must be observed R 5 x D R 10 x D underwater cable Length compensation for the cable must be observed A separate cord grip for cable strain relief is recommended Observe cable routing in case of splashing water water condensation and humidity Pos 29 Sei tenum bruch 0 mod_1353584168894_0 docx 33...

Страница 14: ..._1353584168894_0 docx 336 1 Possible malfunction of the sensor when used in systems with highly interference prone components such as frequency inverters Recommended wiring Use single shielded sensor cable with twisted pair conductors for power supply and signal output Connect the cable shield to ground on one side of the control cabinet Connect the shield connection over a large area using cable ...

Страница 15: ...mage Inspection of Measures Integrity of housing Send damaged sensor to ASM for repair Integrity of connector cable Replace damaged parts resp send sensor to ASM for repair Mounting elements Tighten mounting parts with recommended torque if applicable use bolt adhesive Measuring tape Damaged tape e g bended tape send sensor to ASM for repair Opening the following sensors will cause damage and void...

Страница 16: ...cx 48453 1 1 5 Output specification Pos 39 Bedienungsanl eitungen Positape M esssignal und M essber eich WBT 7 m od_1530274908249_78 docx 57135 2 1 5 1 Measurement signal and range Digital absolute Absolute encoder Measurement range corresponds to a digitally coded number resolution eg 10 steps mm Position 0 30 100 Measurement value example 0 steps 3 000 steps 10 000 steps Pos 40 Sei tenum bruch 0...

Страница 17: ...or SDO default 127 PDO 3 TxPDO 0 RxPDO no linking static mapping PDO Modes Event Time triggered Remote request Sync cyclic acyclic SDO 1 Server 0 Client CAM 8 cams Certified Yes Transmission rate 50 kBit bis 1 Mbit adjustable via LSS or SDO default 125 kBit Bus connection M12 conncector 5 pin Integrated bus terminating resistor 120Ω adjustable by the customer Bus galvanic isolated no Specification...

Страница 18: ...t Change parameters only when machine is in a safe condition Changing parameters may cause unexpected machine movement Changing parameters may influence dependent parameters e g changing the resolution may have influence on position of CAM switches Precautions have to be taken to avoid damage to human and machine parts Pos 44 Bedienungsanl eitungen Positape C ANopen_spec_W S_W B CAN bus wiring 4 m...

Страница 19: ...pen Characteristics Device type B Life period electronics MTTFd 320 years channel Probability of failure PFH λDU 350 Fit channel Life period mechanics B10 5 106 cycles draft Probability of failure mechanics λMECH 0 1 Ch B10 Ch cycles per hour Working life 10 years Calibration intervall annually Operating conditions Pull out speed max 1 m s Pull in speed max 1 m s Assembly No deflection Standards F...

Страница 20: ...nik GmbH 2020 All rights reserved Subject to changes without notice See protection note DIN34 ASM Sensors Inc 650 W Grand Ave Unit 205 Elmhurst IL 60126 USA Tel 1 630 832 3202 Fax 1 630 832 3204 info asmsensors com ASM Sales Office UK Tanyard House High Street Measham Derbs DE12 7HR United Kingdom Tel 44 845 1222 123 Fax 44 845 1222 124 info asm sensor com www asm sensor com ...