VIPEDIA-12 – Installation Guide
U-0641-0344.doc – Issue: 06 complete, approved
Page 10 of 44
2.3 Installation
Procedure
!
!
Please read and observe the safety information guidelines available on the product and in Section
“5 Safety and Precautions” (page 42) prior to installation. Failure to follow these instructions and
guidelines may cause personal injury and/or damage to the equipment.
1.
Fit the VIPEDIA-12 into a 19-inch standard equipment rack on supporting rails, and secure the unit in
position using the fixing screws and washers provided; see Figure 1.
Figure 1
Installing the VIPEDIA-12 into the rack
1U
1U
1U
VENTILATION PANEL
VENTILATION PANEL
VIPEDIA-12
SUPPORTING RAILS MUST BE USED.
ENSURE 1U VENTILATION
PANELS ARE FITTED ABOVE
AND BELOW THE EQUIPMENT.
DO NOT OBSTRUCT
VENTILATION HOLES.
!
!
!
!
GENERIC 19-INCH 1U FORMAT
M6 POZIDRIV SCREW
M6 PLAIN WASHER
M6 CAGE NUT
2.
Ensure that the power supply from the central equipment rack is turned off.
3.
If required, fit the memory card(s); see Figure 2 (page 10).
Figure 2
Setting the DBB switch and fitting memory card(s)
IN
+
-
18-40V
2A
18-40V
2A
1
2
CONTACTS OUT
1 - 6
7 - 12
CONTACTS OUT
DBB IN 1
DBB OUT 1
µ
SD 1
DBB
S M
µ
SD 2
DIAG.
ETH 3
ETH 4
ETH 5
ETH 6
VIPEDIA-12 REAR PANEL
Memory card slot
(present if Network
Card is fitted)
Memory card slot
VIPEDIA-12
DBB Switch Position
Factory Default
S
Stand-alone Unit
S
Expansion Unit (DBB Member 2, 3, and 4)
S
Base Unit (DBB Member 1)
M