background image

User Manual PS 130 / Issue 1 © 1994  ASL Intercom, Utrecht, Holland.

5

4.0

FRONT PANEL CONTROLS AND CONNECTOR

5.0

SIDE PANEL CONNECTORS

11 LINE connectors

These XLR-3 connectors are for connecting the PS
130 to the intercom system.

Pin assignments :

1. 0 V / ground shield
2. +30 V power wire
3. audio wire

The female connector is for input.
The male connector is for extending the intercom line
to other stations.

6.0

INTERNAL CONTROLS

Inside the unit there are two trimmers to adjust the mic
gain of the gooseneck microphone and the headset
microphone separately. These internal controls are located
on a P.C.board.

They can be reached as follows :
-

remove the screws of the bottom plate.

The two trimmers are labeled :

-

slide the plate to one side and take it out.

GOOSE for the gooseneck microphone

-

take away the plastic isolation plate.

HEADS for the headset microphone.

Содержание PS 130

Страница 1: ...IPTION 3 2 0 UNPACKING 3 3 0 INSTALLATION 4 4 0 FRONT PANEL CONTROLS AND CONNECTOR 4 5 0 SIDE PANEL CONNECTORS 5 6 0 INTERNAL CONTROLS 5 7 0 CABLING 6 8 0 PARTY LINE TECHNICAL CONCEPT 7 9 0 GUARANTEE...

Страница 2: ...User Manual PS 130 Issue 1 1994 ASL Intercom Utrecht Holland 2...

Страница 3: ...ses reliability and allows When a headset is connected both the gooseneck for microphone and speaker are disabled automatically soft microphone ON switching latched or momentary loudspeaker Smooth ope...

Страница 4: ...the microphone preamplifier from After the CALL button is released the LEDS will clipping when speaking close into the microphone continue to flash for further 2 seconds 4 SIDETONE LEVEL trimmer This...

Страница 5: ...t The male connector is for extending the intercom line to other stations 6 0 INTERNAL CONTROLS Inside the unit there are two trimmers to adjust the mic gain of the gooseneck microphone and the headse...

Страница 6: ...ble screen to XLR pin 1 The screen of each separate microphone cable and or angle of 90 only the screen of each single pair in a multipair cable Intercom cables should never be in the same trunking sh...

Страница 7: ...of the communications signal power and audio to the intercom stations use the same max output current 3 mA rms cable output impedance 150 Kohms The Call signal is also sent as a current on the audio l...

Страница 8: ...User Manual PS 130 Issue 1 1994 ASL Intercom Utrecht Holland 8...

Страница 9: ...User Manual PS 130 Issue 1 1994 ASL Intercom Utrecht Holland 9...

Страница 10: ...User Manual PS 130 Issue 1 1994 ASL Intercom Utrecht Holland 10...

Страница 11: ...User Manual PS 130 Issue 1 1994 ASL Intercom Utrecht Holland 11...