background image

 

 

PAGE 3

 

User Manual IS 640-18 / August 2016 © ASL Intercom BV 

 

 

 

 
 

 

 
 

4.0     INTERNAL WIRING  IS 640-18 

 

 

 

 
Pin 3 connections: 

Each slide switch assigns the audio wire of each 
intercom line (labeled 1 

– 18) to the audio wire of 

one of the 6 intercom channels (labeled A 

– F).  

 

Pin 1 connections: 

The 0V/ground wire of all intercom channels are 
connected to the ones of all intercom lines. 

 
Pin 2 connections: 

The 30V DC line power for the intercom lines with 
odd numbers is derived from the line power on 
channel A, C and E.   
The 30V DC line power for intercom lines with 
even numbers is derived from the line power on 
channel B, D and F.   

 
 

5.0 

DIMENSIONS & WEIGHT 

 
Width:   

19” / 483 mm 

Height:   

1

,75” /44,5 mm 

Depth:  

25 mm 

Weight: 

320 grams 