E l e c t r i c a l   c o n n e c t i o n  

The device is intended for fixed connec on only and may be connected only to fixed cables. Select a 
cable cross-sec on suitable for the power ra ng of the device. All poles of the device must be able to 
be disconnected from the mains by means of an at least 3 mm isola ng distance. The PE wire must be 
100 mm longer than the other conductors. 
 
 

I n   t h e   e v e n t   o f   t h e   f o l l o w i n g   t h e   g u a r a n t e e   i s   v o i d :  

-  Not complying with this paperwork „Fi ng instruc ons, user manual and service“ 
-  Not complying with the boiler manufacturer's fi ng instruc ons  
-  Technical modifica ons, repairs or tampering with the device (including exchanging the thermostat)  
-  Applica ons for which the device was not designed  
-  Incorrect opera on and maintenance  
-  Not complying with direc ve VDI 2035 
 
 
 

A p p l i c a b l e   s t a n d a r d s  

Safety: 

EN60335-1 / -2-21 / -2-73 

EMC: 

EN55014-1 / -2 

CEM:  

EN62233 

IP Code: 

EN60529 

Содержание ASKOHEAT-F Series

Страница 1: ...angers Children may not play with the device The device may not be cleaned or serviced by children unless they are supervised General safety information Installation setting and removal must be carrie...

Страница 2: ...been reached the device automa cally switches o and switches on again if necessary If you only want frost protec on when you are on holiday you can turn the rota ry knob to the required posi on User...

Страница 3: ...5 C This prevents the safety temperature limiter of the ange heater tripping Safety temperature limiter The safety temperature limiter may trip at temperatures lower than approx 15 C e g transporta on...

Страница 4: ...least 3 mm isola ng distance The PE wire must be 100 mm longer than the other conductors In the event of the following the guarantee is void Not complying with this paperwork Fi ng instruc ons user ma...

Страница 5: ...Fitting instructions ASKOHEAT F Flange heater 180 mm ASKOHEAT F_180_2 9_en MVGASV_120101_en_V3 www askoma com Page 5 7 8 1 6 3 4 5 2...

Страница 6: ...instructions ASKOHEAT F Flange heater 180 mm ASKOHEAT F_180_2 9_en MVGASV_120101_en_V3 www askoma com Page 6 9 Posi on right For stainless steel boiler Posi on le For black steel enamelled boiler 10 1...

Страница 7: ...age L1 L2 L3 400 V 3 2 0 9 0 kW 1 N 230 V Clamp 1 Connector from power plant hp release auxiliary hea ng The regula ons of the local electrical power u li es must be complied with 2 0 to 9 0 kW type C...

Страница 8: ...101_en_V3 www askoma com Page 8 2x year When the heater is used in hard water areas it must be regu larly descaled It is impera ve that the local circumstances are paid a en on to The build up of scal...