TD 77

 S5 Start/Stop

Start a program by pressing the button and stop by pressing it for 3 seconds.

 S6 Time delayed start

The start of a program can be delayed for 1-12 hours. Push the button so many
times that you want the start to be delayed. By thirteenth press, the delay will be
zero. D3 and D4 indicate the chosen amount of hours.

Test program

Through pressing S1.1 5 times and S1.2 for 5 times, you get into a test program.
A press on

S1.2 will lit

L1-L4 and

D1-D2

S1.3     ”

L5-L8 ”

D3-D4

S4 The buzzer is activated

S1.4 starts the motor,heater, high effect, heater low effect, and
outlet pump .

There will be a heating up till 50° C . After that the heater, low effect,  is turned off.
The  heating-up continues to 60°C and then all components are shut off.
During the heating-up the moisture in the machine is indicated by D1 and D2
(normally  3-13).  D3 and D4 indicate the temperature.

Fault signals:

The following codes are indicated by D3 and D4.

F1

Overfilling in the condensate water container

F2

Maximal drying time, 3 hours

F3

Thermistor fault

F4

Fluff in the fluff filter or in the condenser (indicated after end of program)

F5

Fault in the moisture sensor

Reasons for faults

Open-circuited or short-circuited thermistor

This will interrupt the program and produce a flashing F3 on the display. An open circuit
can be caused by a  broken connection or a faulty thermistor. The resistance of a
helthy thermistor is between 60 kohm and 40 kohm at 20-30°C.

Thermistor not in thermal contact with the fan casing

The heating element will be energised as long as the thermistor does not sense the air
temperature called for by the program, resulting in excessive air temperature.

Содержание TD70

Страница 1: ...INDEX TD70 TD73 TD76 TD77 DRYERS...

Страница 2: ...Content Page Tumble dryers TD70A 1 2 TD73A 3 7 TD76A 8 9 TD77A 10 14...

Страница 3: ...omatic programs can be started in setting 1 or 2 Setting 2 is more used and gives drying to selected temperature after which the program continues for about 14 minutes without any heat Setting 1 start...

Страница 4: ...otor is a bi polar unit with direct coupling fan and gear facility for driving the drum Capacitor The capacitor is 8 uF mounted on the component bridge Heating element The heating element with 1900 95...

Страница 5: ...The keyboard includes pushbuttons and indicators Main On Off switch The main On Off switch is fitted in the centre of the lower edge of the panel is a 2 pole switch and disconnects the phase and the z...

Страница 6: ...or gets a short circuit the program is stopped See fault signal F3 Moisture sensing A moisture sensor measuring the humidity of the circulating air controls the drying process The output from the sens...

Страница 7: ...eriod S1 5 Timed program One press on S1 5 means 5 min drying time cool down till the air temperature is 40 C or maximum 15 minutes Continued pressings increases the drying time to 10 15 20 30 50 60 7...

Страница 8: ...During the heating up the moisture in the machine is indicated by D1 and D2 normally 3 13 D3 and D4 indicate the temperature Fault signals The following codes are indicated by D3 and D4 F2 Maximal dry...

Страница 9: ...ing suppIy fuses blown Fuse L1 blown Machine will stop after ca 20 minutes Heater power will be reduced 720W Fuse L2 blown The machine will not start Main power On light extinguished Fuse L3 blown Mac...

Страница 10: ...can set this sequence directly and to get an airing program The program unit The program unit has a mecanically marked setting points motor with 4 min stages and built in buzzer Pushbuttons The pushbu...

Страница 11: ...heating and when the door is opened Door contact The door contact is activated by the door and breaks the operating circuit Condensate water pump There is a pump in the machine to pump water from the...

Страница 12: ...ch The main On Off switch is fitted in the centre of the lower edge of the panel is a 2 pole switch and disconnects the phase and the zero line Indicating lamp The indicating lamp shows that the main...

Страница 13: ...Temperature sensing Machine temperature is controlled by a thermistor for exact control If the ther mistor is loose or gets a short circuit the program is stopped See fault signal F3 Moisture sensing...

Страница 14: ...eriod S1 5 Timed program One press on S1 5 means 5 min drying time cool down till the air temperature is 35 C or maximum 15 minutes Continued pressings increases the drying time to 10 15 20 30 50 60 7...

Страница 15: ...are shut off During the heating up the moisture in the machine is indicated by D1 and D2 normally 3 13 D3 and D4 indicate the temperature Fault signals The following codes are indicated by D3 and D4 F...

Страница 16: ...ing suppIy fuses blown Fuse L1 blown Machine will stop after ca 20 minutes Heater power will be reduced 950W Fuse L2 blown The machine will not start Main power On light extinguished Fuse L3 blown Mac...

Отзывы: