Thin vacuum sealer bags
▷
Medium vacuum sealer bags
▷
Thick vacuum sealer bags
External vacuuming
1. Press the On/Off touch key until the device is switched on.
2. Use the included hose to connect the external vacuuming accessory with the connection point
in the vacuum chamber.
3. Use the External Vacuum Level touch key to select a low, middle or high level.
4. Press the Start touch key to start the vacuuming process. Vacuuming stops automatically when
the vacuum level has been reached.
WARNING!
Fittings to connect external vacuuming accessories to the hose for use in external vacuuming
are not included with the vacuum drawer. These are dependent on the type of vacuuming
accessory.
Vacuuming failure
If the vacuum drawer cannot vacuum the vacuum chamber, this can
be caused by the following issues:
•
The lid is not or insufficiently pushed in when starting vacuuming.
-
The Vacuuming Failure indicator lights up. Push the lid on the
front into the rubber gasket properly.
•
The oil of the vacuum pump necessary for vacuuming contains
moisture.
-
The Vacuuming Failure indicator and the Dry Run Function
indicator light up.
-
Start the Dry Run Function.
NOTE!
If the vacuuming fails a number of times, then the Vacuuming Failure
indicator and the Dry Run Function indicator light up. It is then
advised to perform the Dry Run Function.
•
A failure has occurred.
-
Call a service organisation.