14
General
This appliance should only be connected by
authorised personnel.
This appliance should be
installed according to the requirements of the local
authority.
Caution!
The type of gas and the country for which the appliance
has been designed are indicated on the application
identi
fi
cation card.
Please contact the ASKO service department if
installation or operational faults occur during
installation.
This is a category 3 appliance.
Gas connection
The gas connection must comply with national and
local regulations.
• The gas connection must comply with national and
local regulations.
• We recommend that the hob be connected by means
of a
fi
xed pipe.
• Connection using a specially designed safety hose is
also permitted.
• Behind an oven always install a full metal pipe.
Warning!
• Ensure that the hose assembly is restrained from
accidental contact with the
fl
ue or
fl
ue outlet of an
underbench oven. The hose should not be subjected
to abrasion, kinking or permanent deformation and
should be able to be inspected along its entire length.
Unions compatible with the hose
fi
ttings must be
used and connections tested for gas leaks. The
supply connection point shall be accessible with the
appliance installed.
• In all cases the connection tap for the appliance must
be positioned such that it is easily accessible.
• Before using the appliance for the
fi
rst time check
the connections using water and washing-up liquid to
ensure that there are no gas leaks.
Electrical connection
230 - 240V - 50Hz - 1.1 W
The electrical connection must comply with
national and local regulations.
• Wall socket and plug must be accessible at all times.
• If you want to make a
fi
xed connection, ensure that a
multi-pole switch with a distance between contacts of
3 mm is installed in the supply cable.
• Do not use an adapter or an extension lead to
connect the device to the electrical mains. Safe
use of the device cannot be guaranteed with these
accessories.
WARNING!
This appliance must be earthed.
Installation, maintenance or repairs should only be
carried out by professionals who are authorized by the
manufacturer, as failure to do so will void the warranty.
The device should be disconnected from the mains prior
to installation, maintenance or repairs. The device is
only disconnected from the electric power if:
• the main switch of the electrical wiring/installation in
the house is switched o
ff
, or
• the fuse for the electrical wiring/installation in the
house has been completely removed, or
• the plug has been pulled out of the socket.
Faulty parts may only be replaced by original Asko parts.
Only those parts are guaranteed by Asko to meet the
safety requirements.
If the connecting cable is damaged, it may only be
replaced by the manufacturer, the manufacturer’s
service organisation or equivalently quali
fi
ed persons, in
order to avoid dangerous situations.