Asko CBB761S Скачать руководство пользователя страница 10

TIP!

The cooker hood can be used in extraction mode or recirculation mode. The air extraction capacity
is adapted to the selected mode. The hood will start up in the default extraction mode. Is has to
be reset for recirculation mode.

With an RMS kit (Recirculation modification set) the air will first be cleaned by the grease filters
and then odours will be filtered by the charcoal filter. The cleaned air is recirculated back into the
kitchen.

Switching on recirculation mode

When the light and fan are off, simultaneously hold the timer key and
the light key until the filter indicator flashes 3 times.

The carbon filter indicator is activated.

Switching off recirculation mode

When the light and fan are off, simultaneously hold the timer key and the light key until the filter
indicator lights up for 3 seconds and then turns off.

Clean Air function

The Clean Air function allows you to freshen the air in your kitchen for a maximum of 24 hours at
level 1.

1. Switch off the cooker hood.

2. Press and hold the ‘clean air’ key for approximately 3 seconds.

The cooker hood will switch on automatically for 10 minutes every hour at the lowest speed
setting. During extraction the display will show a fast moving ‘snake’. When the hood switches
off after 10 minutes, the display will show a slow moving ‘snake’ until the hood switches on again
after 50 minutes.

3. Switch off the Clean Air function by pressing the timer, clean air, ‘-’ or ‘+’ keys (any key other

than the light key).

10

Remote control

Содержание CBB761S

Страница 1: ...INSTRUCTIONS FOR USE Cooker hood EN CBB761S CBB861S...

Страница 2: ...mote control 8 Pairing the remote 9 Switching extraction on and off 9 Switch on the boost setting 9 Switching on the timer 10 Switching on recirculation mode 10 Switching off recirculation mode 10 Cle...

Страница 3: ...IRP average calculated Maximum output power 7 dBi Maximum antenna gain Hereby ASKO Appliances AB declares that the radio equipment type Cooker hood Ceiling unit is in compliance with Directive 2014 53...

Страница 4: ...ator 3 Lighting button switches on off and dims the lighting 4 Light indicator 5 Speed down button reduces air extraction capacity and switches off 6 Speed up button switches on and increases air extr...

Страница 5: ...eleasing the button 5 To switch off the cooker hood from press and hold the button for at least 1 second Switch on the boost setting 1 Press and hold the button for at least 1 second The boost setting...

Страница 6: ...ated Switching off recirculation mode Simultaneously press and hold the timer button and the light button until the filter indicator lights up for 3 seconds and then turns off Clean Air function The C...

Страница 7: ...ng strength 3 To turn off the light quickly press and release the light button while the light is on The lighting changes from maximum to minimum strength and vice versa Changing the colour temperatur...

Страница 8: ...e remote This remote control must be paired to the cooker hood before first use 1 Start up the appliance power on Press and hold the and for 3 seconds The hood will start pairing mode for 5 minutes 2...

Страница 9: ...is to prevent the functions from being accidentally switched on or off Switch on the boost setting 1 Press and hold the button for at least 1 second The boost setting is switched on for 10 minutes Th...

Страница 10: ...vated Switching off recirculation mode When the light and fan are off simultaneously hold the timer key and the light key until the filter indicator lights up for 3 seconds and then turns off Clean Ai...

Страница 11: ...d the light key for 1 second NOTE Lighting and motor key must be pressed for at least 1 second This is to prevent the functions from being accidentally switched on or off Changing the colour lighting...

Страница 12: ...Then rinse with clean water Do not use aggressive cleaning agents such as caustic soda The cooker hood finish stays in good condition if it is buffed periodically following the application of wax NOT...

Страница 13: ...ng agent and a damp cloth Dry off with a paper towel Replacing cassette filter The filter should be placed with the locking mechanism on the front Open the filter access latch The notches at the front...

Страница 14: ...erable active carbon filter are thoroughly dry before repositioning Replacing the carbon filter To replace the carbon filter consult the manual for the recirculation kit Filter indicator Saturation of...

Страница 15: ...rtened if the voltage of the battery is too low Don t forget to remove the batteries if you don t use the remote for a long time Don t leave the remote lying upside down on a conductive surface The wa...

Страница 16: ...ing Efficiency LEhood lux W A A Lighting Efficiency class 91 6 94 2 Grease Filtering Efficiency GFEhood B B Grease Filtering Efficiency class 242 387 258 415 Air flow at minimum and maximum speed in n...

Страница 17: ...low rate at best efficiency point QBEP m3 h 493 481 Measured air pressure at best efficiency point PBEP 136 133 Measured electric power input at best efficiency point WBEP 2 8 2 8 Nominal power of the...

Страница 18: ...a responsible manner and in accordance with government regulations The product has been marked with a crossed out dustbin symbol to remind you of the obligation to dispose of electrical household app...

Страница 19: ...843799 www asko com We reserve the right to make changes a1...

Отзывы: