3. Installation tips 

(1)

 

Before installing the sensor, flush all piping passages clean. 

(2)

 

For accuracy, provide straight piping of more than 10 times the inner diameter of the pipe 
on the upstream side, and more than 4 times on the downstream side. Do not install curved, 
confluence, or branch piping (, that is, elbow, tee, throttle valve ), near the outlet. 

                             

Model 

Upper Flow Passage  Lower Flow Passage 

DFS-1 

> 100 mm 

> 40 mm 

DFS-2 

> 140 mm 

> 60 mm 

DFS-3 

> 170 mm 

> 70 mm 

DFS-6 

> 270 mm 

  > 110 mm 

DFS-8 

> 340 mm 

  > 140 mm 

 
(3)

 

The sensor does not have a dedicated “in port” and “out port”. Therefore, you can use either 
port for connecting the in-flow and out-flow pipes. 

(4)

 

When connecting pipes, avoid torqueing, bending, or applying any unnecessary load to any 
portion of the sensor except for the hexagonal part on either end. 

Ensure that the piping is properly supported.    Do not remove the amplifier box from the 
body. 

(5)

 

Avoid operating the sensor near areas containing a strong magnetic field or static electricity. 
Doing so may cause the sensor to malfunction. 

 
 

4. Necessary considerations 

(1)

 

Be sure to use the sensor within the maximum flow rate for your model.    Exceeding the 
flow rate may shorten the life of this sensor or cause damage. 

(2)

 

Be sure that the fluid flowing through the sensor is clean, or install a “filter” to prevent 
clogging. 

(3)

 

Avoid using the sensor with fluids that contain magnetic materials; the sensor contains a 
permanent magnet, and magnetic materials in the fluid may cause the sensor to 
malfunction. 

Recommended Filtration Element and Available Fluid

 

Model 

DFS-1 

DFS-2, 3, 6 

DFS-8 

Available Fluid 

(Filter Element) 

Hydraulic oil, Lubricating oil 

(5

20 

μ

m) 

-------- 

Water, Water-soluble cutting oil 

(20

50 

μ

m) 

昆山瑞

精密自动化有限司 

 

 

 

 

昆山瑞

精密自动化有限司

Содержание DFS-1

Страница 1: ...tips 4 Necessary considerations 5 Description of Model No 6 Wiring connection 7 Explanation of function 8 How to configure 9 How to remove a contaminant 10 Specifications ASK CORPORATION 1 34 16 Higa...

Страница 2: ...maximum pressure is lower than 3 MPa 30 bar and the flow sight function is necessary a metal plastic cap can be used 2 Be sure to use the sensor within its maximum pressure Do not exceed this maximum...

Страница 3: ...the sensor except for the hexagonal part on either end Ensure that the piping is properly supported Do not remove the amplifier box from the body 5 Avoid operating the sensor near areas containing a s...

Страница 4: ...ead 1 Rc 1 8 2 Rc 1 4 3 Rc 3 8 6 Rc 3 4 8 Rc 1 FLOW MEDIUM O Hydraulic oil Lubricating oil W Water Water soluble cutting oil CUSTOM SPECIFICATIONS Please ask us 6 Wiring connection M12 1 4 pin connect...

Страница 5: ...ut alarm You can configure the output alarm within use flow rate range The relation of flow rate adjusted value LED indications and the output is shown below For details see Section 8 Flow Rate Less t...

Страница 6: ...r Cancel Switch to output alarm mode Configure Output Alarm Press to select a value Hold to scroll through the numbers quickly For decision Switch to measuring flow rate Configure a value within use f...

Страница 7: ...before performing this procedure 1 Remove the cap installed on the center of the body see below 2 Using an air blower blow out the contaminant toward the downstream side of the sensor 3 Re install the...

Страница 8: ...temperature MATERIALS FLUID CONTACT PARTS C3604 Ni Plaiting Nd Fe B Ni Plaiting POM PC plastic metal cap only NBR O Hydraulic oil Lubrication oil W Water Water soluble cutting oil We adjust each type...

Отзывы: