Technical Specification

1.5.1 Absolute Maximum

Ratings

Operating temperature

min. 0 °C

max. +70 °C

Storage temperature

min. -55 °C

max. +85 °C

Active USB current

max. 100 mA

All input voltages to signal
ground

±25 V

All output voltages to
signal ground

±13 V

ESD immunity

±8 kV contact HBM

±6 kV air HBM

±15 kV Human Body Model

Electric Field Immunity

3 V / m

Table 2: Absolute Maximum Ratings

1.5.2 Operating

Specifications

Minimum data rate

300 Baud

Maximum data rate

220 kBaud guaranteed,
500 kBaud typically

Input Treshold Low RS-232

min. 0.8 V, typ. 1.5 V

Input Treshold High RS-232

max. 2.4 V, typ. 1.8 V

Output voltage Swing

1

min. ±5 V, typ. ±5.4 V

Short-circuit tolerance

No limit

Short-circuit current

maximum ±60 mA

Operating system

Windows

2

 32/ 64-bit

Linux 1.5.0 32/64-bit

MAC OS 10 32/64-bit

Windows CE

3

RS-232

full implementation

RS-232 connector

DB9

USB 1.1 a 2.0 compatibility

yes, 12 Mbps (Full Speed)

USB connector

A type

Length of USB cable

1 m

Transmit indicator

red LED

Receive indicator

green LED

Table 3: Operating Range

1

 Outputs Loaded with 3 kΩ.

2

 Windows 8, Windows 7, Windows Server,

Windows Server 2003, Windows Vista, Windows XP.
Compatible with 32/64 bit. version.

3

 Windows Mobile 2003, Windows Mobile 2003 SE,

Windows Mobile 5, Windows Mobile 6,
Windows Mobile 6.1,Windows Mobile 6.5

Содержание UCAB232

Страница 1: ...UCAB232 Reference Manual RS 232 interface for USB...

Страница 2: ...support asix net sales asix net ASIX s r o reserves the right to make changes to this document the latest version of which can be found on the Internet ASIX s r o renounces responsibility for any dam...

Страница 3: ...ternal influences 1 4 4 6 1 5 Technical Specification 6 Absolute Maximum Ratings 1 5 1 6 Operating Specifications 1 5 2 DRIVERS 7 2 7 2 1 Drivers Installation 7 Windows operation system 2 1 1 Windows...

Страница 4: ...ation proprietary ID can be used Low power consumption USB suspend mode Cable length 1 m 1 3 Quick Start It is necessary to install drivers before first use 1 3 1 Windows Please insert USB plug connec...

Страница 5: ...data rate is within the range of 300 Baud to 250 kBaud The UCAB232 converter allows to communicate typically over 500 kBaud However this data rate is not guaranteed and could depend on temperature and...

Страница 6: ...typ 1 5V InputTresholdHighRS 232 max 2 4V typ 1 8V OutputvoltageSwing1 min 5V typ 5 4V Short circuittolerance Nolimit Short circuitcurrent maximum 60mA Operatingsystem Windows2 32 64 bit Linux1 5 032...

Страница 7: ...XP When a new device has been detected by operating system it is necessary to agree searching the drivers on the Windows Update and continue with automatic installation The installation continues the...

Страница 8: ...signed COM port number by operating system The COM port number can be found and or changed in Control Panel Device Manager Ports If the RS 232 connected device does not reply LED indicator does not bl...

Страница 9: ...PID which are originally set to 0403 6001 to customer numbers and write these numbers with the FT_PROG utility to the converter EEPROM Before a modification of EEPROM it is advisable to create a back...

Страница 10: ...Page 10 3 Document history Document revision Modificationsmade 2014 05 30 Newlycreateddocument 2014 06 11 Driverssectionupdated...

Отзывы: