Operating Manual - PROTEA SYSTEM II  4.24D  Distribution / System Processor

A preset file contains the control parameters of all four inputs and eight outputs, but does not retain any MIDI

channel information, as MIDI channel is arbitrary within an installation.  For a written record of all parameters of a
specific preset file, click <Print Channel> in the File menu.

Since there are no user controls on the 4.24D, the only way to load channel presets is by using Protea System

Software to recall files saved on either the PC or the 4.24D.  The exception to this is through the use of contact
closures, where presets 1-8 from the 4.24D memory can be loaded using switches wired to the rear panel contact
closure connector block (see section 5.4).

Note:  A preset recall event will overwrite any changes to the working channel (also known as the working

preset or current channel on older Protea products), so be sure the current configuration is saved before continuing or
it will be lost.  The 4.24D always loads the last working channel on power-up, so as to preserve any changes should the
power be inadvertently turned off prior to saving a channel.

Caution:  A new preset may have dramatically different settings capable of damaging sound system compo-

nents, so be careful not to recall the wrong preset while the system is on.  To be safe, always select "Yes" to mute all
outputs.

8.2  MIDI Dump

To capture the entire set of 30 presets stored within a specific 4.24D's memory, a <*.dmp> file is created by

clicking <Trigger MIDI Dump From Protea> within the Protea System Software file menu.  This file can then be
written back to the same or another 4.24D using <Download MIDI Dump To Protea>.  When a MIDI Dump download
to a 4.24D is complete, the display shows a lower case "d" to confirm the event.

Additionally, one 4.24D can dump directly to another 4.24D if the unit connected to the PC is also the one

whose settings are to be copied forward to the next unit through the MIDI connection.  In other words, using <Trigger
MIDI Dump From Protea> always writes to the next Protea object in the MIDI loop, whether it's another 4.24D or a
PC.  MIDI dump data is device specific, so don't attempt a dump from a 4.24D to a different type Protea device, such
as a 4.24C, graphic EQ, or Parametric EQ.  Note that MIDI channel assignment, security, and preference information
is not included in the dump.

8.3  Copying Settings to Another Input Or Output

The <Copy/Paste> functions are used to quickly transfer all settings from one currently selected input or

output within the 4.24D to another input or output channel within the same unit.  An example of how this might be
used is with stage monitors.  Let's say there are eight monitor mixes on stage, and they all use the same type of floor
wedge.  The first monitor could be set up with Gain, EQ, and Limiting, then those settings could be quickly copied to
the remaining seven monitors, providing a consistent starting point for each mix.  To copy, first select the input or
output to copy from, then click <Edit/Copy>, then click on the input or output to copy to, clicking <Edit/Paste> to
complete the action.

8.4  Security

There are three levels of protection assignable to the 4.24D within the software <Security> pull down menu.

The first level <Lock 4.24D Presets> allows the user to edit any settings or recall new presets, but not to save changes.
The second level <Lock 4.24D> locks all controls for the 4.24D and disallows saving or recalling new channel presets.
The third and highest level of security <Lock Protea System Software> completely locks all devices under control of
Protea System Software so that absolutely no changes can be made to any unit.  To unlock a security level, simply re-
enter the password within the <Security> pull down menu.  Passwords are case sensitive.  If the password is forgotten,
it can be viewed by switching to the graphic equalizer device and pressing <Ctrl + Shift + P> on the keyboard.

Содержание Protea 4.24D

Страница 1: ...O INC 847 Holt Road Webster NY 14580 9103 Phone 585 872 0010 Toll Free 800 828 6308 Fax 585 872 0739 w w w ashly c o m 4 24D 24 Bit Digital Distribution System Processor Operating Manual Digital Audio...

Страница 2: ...3 RS 232 Dataport 6 5 4 Contact Closure Connector 7 5 5 Data In and Data Out Connection 7 5 6 AC Inlet and Power Switch 7 5 7 RS 232 Mode Switch 7 6 PROTEA SYSTEM SOFTWARE 8 6 1 How to Get Protea Syst...

Страница 3: ...ng the device The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of uninsulated dangerous voltage within the product s enclosure tha...

Страница 4: ...two piece terminal block connectors 2 UNPACKING As a part of our system of quality control every Ashly product is carefully inspected before leaving the factory to ensure flawless appearance After unp...

Страница 5: ...top bar within the 4 24D section of Protea System Software MIDI channel 0 removes the device from any MIDI control while still allowing MIDI signal to pass through This display also indicates the foll...

Страница 6: ...at signal levels above 20dBu 7 75Vrms which places the noise floor lower than 90dBu The optimum input signal level which should be fed into the Protea processor is 0dBu 775Vrms This input level will a...

Страница 7: ...contact closure connector equals the number of the preset which will be recalled when that switch is closed Always use the 4 24D contact closure ground for contact closure switches Do not connect the...

Страница 8: ...new Protea 4 24D can be downloaded from the Ashly web site or can be purchased directly from Ashly for a nominal handling fee 6 2 Installing Protea System Software The installation program is the same...

Страница 9: ...are encompasses eight different Ashly Audio products After properly connecting the PC and 4 24D see section 6 3 enable Communications and then select 4 24D from the Devices pull down menu 7 2 Configur...

Страница 10: ...dragging a filter Resets the filter position to its starting position c Cut Active Filter z Zero Active Filter Ctrl c Cut Master Gain Ctrl z Zero Master Gain 7 4b Mute The 4 24D allows the user to mut...

Страница 11: ...l on either side of the frequency center is boost or cut whereas a larger wider bandwidth produces an audible change to the overall tone of a signal Para metric filters are best used to hunt down and...

Страница 12: ...a high pass filter HPF and a low pass filter LPF along with the frequen cies and filter types used Each output s crossover sec tion is essentially a bandpass filter making it necessary for the user to...

Страница 13: ...48dB oct Linkwitz Riley filters individually are always 6dB at the displayed crossover frequency however the 18dB oct Linkwitz filters individually are always 3dB at the displayed crossover frequency...

Страница 14: ...ch gain reduction begins and is indicated by the amber LED S L in the output meter section Increases in audio level above the threshold will be reduced according to the ratio settings The ratio contro...

Страница 15: ...d to the PC is also the one whose settings are to be copied forward to the next unit through the MIDI connection In other words using Trigger MIDI Dump From Protea always writes to the next Protea obj...

Страница 16: ...t gain settings too high Check to see if an EQ filter has too much boost 5 Distorted sound but no Clip LED Check individual EQ filters to see if there is excessive boost 6 Muffled sound If expecting f...

Страница 17: ...kHz Off Available Filter Types 12dB Oct Butterworth 12dB Oct Bessel 12dB Oct Linkwitz Riley 18dB Oct Bessel 18dB Oct Linkwitz Riley 24dB Oct Butterworth 24dB Oct Bessel 24dB Oct Linkwitz Riley 48dB Oc...

Страница 18: ...n the warranty card that came with your product Fill out the information below for your records Model Number _____________ Serial Number ________________ Dealer __________________________ Date of Purc...

Страница 19: ...ute 13 BLOCK DIAGRAM A D Input Mute Input EQ Input Meter LEDs Input Channels A D 40 to 12dB Input Gain 6 Bands of Parametric 1st Order LS 2nd Order LS 1st Order HS or 2nd Order HS Input Clip Indicator...

Страница 20: ...ion System Processor ASHLY AUDIO INC 847 Holt Road Webster NY 14580 9103 Phone 585 872 0010 Fax 585 872 0739 Toll Free 800 828 6308 www ashly c o m 2003 by Ashly Audio Corporation All rights reserved...

Отзывы: