background image

   

ne1600 

 

  ne1600.10   

  ne1600.70

 RATED 

RATED 

RATED 

RATED 

RATED 

RATED 

RATED 

RATED 

RATED

 WATTS 

VOLTS  LOAD 

  WATTS 

VOLTS  LOAD 

  WATTS 

VOLTS  LOAD 

 

 

 

 

800 

100 

12.5 

800 

70 

6.1

  450 

60 

512* 

64* 

8* 

613 

70 

8

  800 

56.6 

256* 

32* 

4* 

522* 

45.7* 

4*

  400* 

28.3* 

2* 

128* 

16* 

2* 

261* 

22.9* 

2* 

 

1600 

113 

1600 

200 

25 

1600 

140 

12.3

5

Operating Manual - NE Two Channel Power Amplifiers

Protection

This amplifier come standard with several protection circuits:

Over Current Protection

 - Is controlled in the output stage.

Thermal Protection 

- The amplifier senses output device temperature and adjusts a two-speed fan to keep the operating 

temperature within acceptable limits. If device temperatures exceed that limit, the input to that channel is first reduced, and as 

a last resort the power supply will be switched off while the fan continues to run.

Mains Protections 

– protection within the power supply includes: Inrush Current Limitation during power up, Mains 

Over Voltage Detection, and internal Mains Fuse Protection. To protect the Mains fuse against AC overcurrent due to excessive 

audio output current, there is a protection scheme controlled in software and indicated on the amplifier front panel which reduces 

audio output level until the overcurrent condition is no longer present.

Physical Description

Each model in the NE two channel series is 2RU, and weighs 22 pounds (10kg) or less. The model number is indicated 

in the lower left corner of the front panel.

Amplifier Front Panel

1. Mounting Holes 

– For rack mounting.

2. Power Switch 

– Switches the unit on or off. 

Note: The power switch can be disabled from software.

3. Status LEDs 

– Indicate status of: Power, Standby, Protect, Power Switch Disable, and Com (Ethernet activity).

4. Air Vents 

– Cool air enters the sides and is blown out the front.

6. Signal LEDs 

– The lowest LED will begin to light when the output voltage reaches -18dBu below rated output. The 

Clip LEDs will begin to flash when output voltage is 1/2 Volt below the output power supply voltage. 

7. Bridge 

– This LED indicates that the two channels are selected to BRIDGE mode from the back panel switch, and that 

only channel 1 level control is active.

8. Temp and Current LEDs 

– The Temp LED indicates that the amplifier has reached an excessively high operating 

temperature. The Current LED confirms that the amplifier output is delivered to a speaker load.

9. Channel Attenuators 

– These control the input signal level to the amplifier section, and can be disabled from software.

10. Factory Reset 

– To reset internal configurations back to their original factory settings, including all device presets 

and user passwords, press and hold this recessed front panel tact switch during power up until all channel LEDs are lit. Upon 

reset completion, the LEDs will turn off and the amp will be in normal operating mode.

Содержание ne1600

Страница 1: ...Webster NY 14580 9103 Phone 585 872 0010 Toll Free 800 828 6308 Fax 585 872 0739 ashly com Network Enabled Two Channel Power Amplifiers Operating Manual ne800 ne800 10 ne800 70 ne800 25 ne1600 ne1600...

Страница 2: ...bsolete outlet 11 Protect the power cord from being walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the ap paratus 12 Only use attachments accesso...

Страница 3: ...owing two conditions 1 This device may not cause harmful interference 2 This device must accept any interference received including interference that may cause undesired operation 2 UNPACKING As a par...

Страница 4: ...DSP Processing PE Factory installed DSP and Proteane software allows amplifier channels to be configured with pluggable DSP blocks for dynamics controls gain functions FIR filters output only graphic...

Страница 5: ...ifier Front Panel 1 Mounting Holes For rack mounting 2 Power Switch Switches the unit on or off Note The power switch can be disabled from software 3 Status LEDs Indicate status of Power Standby Prote...

Страница 6: ...emote Standby Connect these two contact closure pins to remotely place the amp in standby 11 Remote Level Control These pins can be wired to remote potentiometers such as the Ashly WR 1 for level cont...

Страница 7: ...ller Other Ashly Remote Controls for NE Two Channel Amplifiers 1 WR 1 DC Level Controller The WR 1 WR 1E is a dual potentiometer remote DC level controller designed to fit in a standard US UK electric...

Страница 8: ...mputer Link Group Configuration Linking allows for multiple signal processing function blocks to track each other For ex ample if two graphic equalizer blocks are linked any change made to a control w...

Страница 9: ...ple channels In addition to the control surface secondary level control not the main fader most DSP functions have a link group check box in their work window to assign a specific parameter to one of...

Страница 10: ...tions FIR filter output only 48kHz only 2 384 taps Graphic and Parametric EQ Crossover functions output only Delay Metering and a Signal Generator 5 Input Output Matrix Router Any input can be routed...

Страница 11: ...Response 20Hz 20kHz 1dB Damping Factor 8 ohm load 1kHz 250 Input Impedance 20K Ohm balanced Input Sensitivity Switch 26dB 32dB 1 4V Maximum Input Level 21dBu Amplifier Protection inrush current limita...

Страница 12: ...king Depth 0dB to 30dB Gate Threshold 80dBu to 20dBu Range off 100dB to 0dB Attack 0 2ms dB to 50 ms dB Release 5ms dB to 1000ms dB GAIN Gain off 50dB to 12dB Gain w VCA off 50dB to 12dB WR 5 Remote G...

Страница 13: ...with Mute LINKING All functions can be linked to 1 of 16 link groups DSP PROCESSORS Input A D 24 bit Burr Brown PCM4204 Output D A 24 bit Burr Brown PCM4104 DSP Processors 32 bit floating point Sharc...

Страница 14: ...DSP DAC converter option required Remote Control Options Vary With Configuration DSP Required for Most Programmable Functions Protea NE Software Control Factory Options bypassed if not installed 1 4V...

Страница 15: ...r is altered defaced or removed ASHLY AUDIO reserves the right to make changes in design or make additions to or improvements upon this product without any obligation to install the same on products p...

Страница 16: ...0 Phone 585 872 0010 Fax 585 872 0739 Toll Free 800 828 6308 ashly com 2015 by Ashly Audio Corporation a division of Jam Industries Ltd All rights reserved worldwide Printed in USA r09 All features sp...

Отзывы: