Pedestal Pumps

Models: PED Series 

Installation

 

8. Plastic PVC pipe can be installed in the outlet pip 

  ing. Drain hose, galvanized steel or copper pipe  

  may be used if desired. All piping must be clean  

  and free of all foreign matter to prevent clogging. 
9. Pump will be inadequate if suspension liquids con- 

  tain solid particles larger than 3/16” for EPP or 3/8”  

  for EPC.

 

     

   

Verify that the voltage and  

     

   

frequency of the pump shown 

on the nameplate corresponds to those available on 

the mains. The installer must make sure that the  
electric system is grounded in accordance with code. 
•  For outdoor use it is necessary to use cable with a  
  length of  at least 8’. The plug and connection    
  should be protected from water splashes. Before  
  using the pump, always in spect it visually 
  (especially power cable and plug). 
•  Do not use pump if it is damaged 
•  If the pump is damaged, have it inspected by an   

  authorized service center. 
•   Make sure that electric connections are pro 

 

  tected from flooding. Protect the plug and the    

  power cable from heat or shape edges. 

     
     

   

The power cable must be re 

     

   

placed by qualified personnel 

only. Grounding: The plug of the power cable has a 

double grounding contact, so that grounding can be 

performed by simply inserting  the plug. 

This pump series has a built in thermal protection 

switch. The pump stops if an overload condition  

occurs. The motor restarts automatically after it has 

cooled down.

ELECTRICAL WIRE CONNECTION

OVERLOAD PROTECTION

Do not work on pump until power is unplugged. 
Do not cut off ground pin or use an adapter fitting. 
Do not use an extension cord. 

 

 

 

The pump power cord should be connected to a 

separately fused, grounded line with a minimum  

capacity of 15 amps. It can be connected to non-fuse 

breaker at the recommended amperes. 
1. Before installing or servicing this pump, be  

 

  certain pump source is disconnected. 
2. Installation and electrical wiring must adhere    

  to state and local codes and must be completed  

  before priming pump. Check appropriate commu 

  nity agencies, or contact local electrical and pump  

  professionals. 
3. Call an electrician when in doubt. Pump should be  

  connected to a separate 15 amp circuit breaker   

  or 15 amp fuse block.  

 

 

 

 

  Note that plugging into existing outlets may cause  

  low voltage at motor. This could cause blown fuses,  

  tripping of motor overload or burned out motor. 
4. A permanent ground connection from pump to the  
  grounding bar at the service panel is mandatory.   
  These sump pumps come with a grounding conduc 
  tor and a grounding-type attachment plug. Do    
  not connect pump to a power supply until perma - 
  nently grounded. For maximum safety, connect    
  pump to a circuit equipped with a fault interrupter  
  device when positioning the pump’s grounding wire. 
5. Voltage of power supply must match the voltage of  

  the pump.  
6. Before installing pump, clear sump basin of any   

  water, debris or sediment.  

 

 

 

     

 

 

Sump basin must be vented   

     

 

 

in accordance with local plumb-

ing codes. These Sump pumps are not designed for 

and CANNOT be installed in locations classified as 

hazardous.   
7.  The following may cause severe damage to pump  

  and will void the warranty. 
   (a)  Using an extension cord. 
   (b) Cutting off the ground pin or using an adapter  

     

fitting. 

  (c)  Working on pump or switch while plugged in.
  (d)  Removing motor housing, unscrewing  

 

     

impeller, or otherwise removing impeller seal. 

   (e)  Running the pump continuously. 
  (f)  Pumping chemicals or corrosive liquids. 
  (g)  Pumping gasoline or other flammable liquids

 

Содержание PED33

Страница 1: ...under this warranty is limited to repairing or replacing any part thereof which shall within one year be returned to us with transportation charges prepaid and proved to be defective The above limite...

Страница 2: ...ntact with pumped fluid is possible Risk of electrical shock To reduce risk of electrical shock always disconnect pump from power source before handling Lock out power tag 2 WARNING Do Not use these p...

Страница 3: ...Pumps Models PED Series Specifications 3 9 5 31 4 9 6 1 5 NPT 9 5 9 6 1 5 NPT 9 5 31 6 9 25 1 25 NPT 9 5 31 6 9 25 1 25 NPT 9 5 31 6 9 25 1 25 NPT 31 6 9 25 1 5 NPT PED THERMOPLASTIC PED BRONZE PED C...

Страница 4: ...PER MINUTE 25 20 15 10 5 0 HEAD FEET PED33CI PERFORMANCE CURVE 0 10 20 30 40 50 60 GALLONS PER MINUTE 20 18 16 14 12 10 8 6 4 2 0 HEAD FEET PED50CI PERFORMANCE CURVE 0 20 40 60 80 100 GALLONS PER MINU...

Страница 5: ...nnected to a separately fused grounded line with a minimum capacity of 15 amps It can be connected to non fuse breaker at the recommended amperes 1 Before installing or servicing this pump be certain...

Страница 6: ...must be placed on a hard sur face in a sump that has been cleared of all debris Never place the pump on clay earth or gravel surfaces and it is suggested the pump be placed on two bricks approximately...

Страница 7: ...plugging and unplugging cord Check for clogged vent hole in pump case Inlet holes in pump base are clogged Remove pump and clean the openings Vertical pumping distance is too high Reduce distance or...

Страница 8: ...1899 Cottage Street Ashland Ohio 44805 Telephone 855 281 6830 Fax 877 326 1994 ashlandpump com P U M P H o n e s t P r o f e s s i o n a l D e p e n d a b l e PED33 50 OM 5 2015...

Отзывы: