9
Receiving Inspection
Upon receiving the pump, it should be inspected for
damage or shortages. If damage has occurred, file a claim
immediately with the company that delivered the pump. If
the manual is removed from the packaging, do not lose or
misplace.
Storage
Any product that is stored for a period longer than six (6)
months from the date of purchase should be bench
tested prior to installation. A bench test consists of, check-
ing the impeller to assure it is free turning and a run
test to assure the motor (and switch if provided) operate
properly. Do not pump out of liquid.
IMPORTANT! A clearance under the
pump for entrance of sewage solids
must be a minimum of 3 inches to a maximum of 4.5
inches.
Submergence
The pump should always be operated in the submerged
condition. See Minimum submergence and pump clear-
ance levels below in figure 1
WARNING
Installation
The sump or basin shall be sealed and vented in accor-
dance with local plumbing codes. This pump is designed to
pump domestic wastewater, nonexplosive and noncorrosive
liquids and shall NOT be installed in locations classified as
hazardous in accordance with the National Electrical Code
(NEC) ANSI/ NFPA 70 or Canadian Electric Code (CEC).
The pump should never be installed in a trench, ditch,
or hole with a dirt bottom.The legs will sink into the dirt and
the suction willbecome plugged.
Solids Handling Pumps
Models: 3ANC300/500/750,
4ANC2500/3000/4000/5000/6000
6ANC1000/1500/2000/3000/4000/5000/6000
8ANC5000/6000 Receiving and Installation
Содержание 3ANC300
Страница 5: ...5 Solids Handling Pumps Models 3ANC300 500 750 4ANC2500 3000 4000 Performance ...
Страница 7: ...7 Solids Handling Pumps Models 6ANC3000 4000 5000 6000 Performance ...
Страница 8: ...8 Solids Handling Pumps Models 8ANC5000 6000 Performance ...
Страница 18: ...18 Solids Handling Pumps Models 4ANC2500M4 35 4ANC3000M4 35 Repair Parts ...
Страница 20: ...20 Solids Handling Pumps Models 4ANC4000M4 35 Repair Parts ...
Страница 22: ...22 Solids Handling Pumps Models 4ANC5000M4 35 4ANC6000M4 35 Repair Parts ...
Страница 26: ...26 Solids Handling Pumps Models 6ANC3000M4 35 Repair Parts ...
Страница 28: ...28 Solids Handling Pumps Models 6ANC4000M4 35 6ANC5000M4 35 and 6ANC6000M4 35 Repair Parts ...
Страница 30: ...30 Solids Handling Pumps Models 8ANC5000M4 35 and 8ANC6000M4 35 Repair Parts ...