ASG-NW2500 Network Module 

ACOP / EtherNet/IP

TM

 / ToolsNet 

 

 

User Guide 

 

 

 

Version 1.0.3 

May, 2018 

 

 

Document NW2500-1 EN 

Original Instructions 

Содержание X-PAQ ASG-NW2500

Страница 1: ...ASG NW2500 Network Module ACOP EtherNet IPTM ToolsNet User Guide Version 1 0 3 May 2018 Document NW2500 1 EN Original Instructions...

Страница 2: ...Release June 2017 Updated May 2018 ASG NW2500 Firmware Level v4 0 5 To download the latest version of this manual visit www asg jergens com ASG Precision Fastening 888 486 6163 15700 S Waterloo Rd Cl...

Страница 3: ...7 Quick Start Guide 7 Overview 9 Device Connectivity 9 Network Human Machine Interface HMI 10 ACOP functionality 22 EtherNet IPTM functionality 25 Bar Codes ACOP Communication Only 30 Serial Printer...

Страница 4: ...he product has been damaged in any way When the unit displays a negative distinct change in performance Do not operate or plug in the controller system with wet hands or in wet environments Failure to...

Страница 5: ...nsure the surface cleaned is fully dry before reconnecting power Never modify or disassemble any component of the system Modification or disassembly of the system could result in injury and void the w...

Страница 6: ...hysical skills Consult with your management and advise them of your condition Do not operate this equipment without all guards and covers in place WATER AND MOISTURE Do not place containers with liqui...

Страница 7: ...ough ACOP Open Protocol or EtherNet IPTM EIP formats It also allows for communication using Atlas Copco ToolsNet software Quick Start Guide Installation Remove the protective cover from the X PAQTM co...

Страница 8: ...assword The default password is 0104 6 The first entry of the programming menu is the IP Address Press ENT to change the address 7 Using the arrow keys input the address provided by your network admin...

Страница 9: ...mware or upload log data Network Connector RJ45 The Ethernet port is used to transmit and receive TCP IP messages in one of the above mentioned protocols Serial Printer Serial ACOP Communication A fem...

Страница 10: ...avigate between menu choices and character fields and to toggle between programmed options ENT Key Used to select a menu option or save a program change within a menu ESC Key Used to return to a previ...

Страница 11: ...tart Guide earlier in this document This is the address the plant control system needs to use to communicate with this unit ACOP Task This screen shows the currently active task number This number sho...

Страница 12: ...assword for the unit The default password is 0104 Once at the setup menu cycle through the various menu options using the up and down arrows Pressing ENT will go to the editing screen for the selected...

Страница 13: ...menu determines the gateway address used by the ASG NW2500 Ask your network administrator for the correct value for this setting All units in the same network will generally have the same gateway addr...

Страница 14: ...n this document for output format examples Note When the serial printer format is set to None no data will be transmitted from the RS 232 port Bar Code Reader This menu determines the baud rate of the...

Страница 15: ...orted by the ASG NW2500 in ACOP messages Letters numbers and some special characters _ are allowed Note This field has no relation to the serial number programmed into the connected ASG SD2500 tool Re...

Страница 16: ...rk connections The ASG NW2500 is set to the port recommended in the protocol specification by default All units in the same network will generally have the same port number Only change this value if y...

Страница 17: ...mendation Set the Keep Alive on the ASG NW2500 to at least twice the period at which the control system sends the keep alive packet to ensure a single missed packet does not cause a connection to be d...

Страница 18: ...ion 4 4 of the Atlas Copco Open Protocol specification Default Yes Values No Yes Cell ID This menu sets the 4 digit Cell ID reported by the ASG NW2500 in ACOP result messages Only numbers 0 9 are allo...

Страница 19: ...f you have a server set up in the network Default Disabled Values Disabled Enabled PIM Address This setting controls the IP address the ASG NW2500 will use to establish a ToolsNet connection Default 1...

Страница 20: ...ackets are being sent When set to 0 the ASG NW2500 does not send keep alive packets Default 30 seconds Range 0 to 3600 seconds This value is recommended to be less than half the inactivity timeout of...

Страница 21: ...er before considering the connection broken If no response is received within the specified result timeout the ASG NW2500 will try again up to the specified number of retries If no response is receive...

Страница 22: ...14 0017 1 Parameter set selected subscribe acknowledge unsubscribe 0018 1 Select Parameter set 0020 1 Reset Parameter set batch counter 0030 0031 1 2 Job ID upload request reply 0034 0037 1 4 Job info...

Страница 23: ...the commands received from the ACOP network The mapping will be X PAQTM Input Number 1 2 3 4 5 6 7 8 Task Selection Reset Enable Disable The Select Pset command MID 0018 will change the X PAQ Inputs 1...

Страница 24: ...and MID 0042 is received and will be again deactivated after the next fastening cycle or when the next ACOP command affecting this byte or batch reset barcode is received Note Remote Halt of a Task in...

Страница 25: ...ment are available upon request from ASG or on the product page of the website for the ASG NW2500 Basic Setup The procedure required for making an EtherNet IPTM connection to the ASG NW2500 will large...

Страница 26: ...stead When used in an array indicates a fixed length string instead of the length prefixed strings defined by the specification Fixed length arrays are represented as TYPE n where TYPE is the element...

Страница 27: ...Total size 1 byte 27...

Страница 28: ...ening Rolling Count UINT Number of tightenings that have occurred big endian Total UINT Number of batches completed in the parameter big endian Time CHAR 6 ASCII digits of time of last tightening in H...

Страница 29: ...unt of the last tightening Batch USINT The batch size of the last tightening Rolling Count UINT Number of tightenings that have occurred Total UINT Number of batches completed in the parameter Reserve...

Страница 30: ...The data is grouped into sections separated by a percent symbol The general structure for a command bar code is command data Note When setting up the barcode scanner do not add a carriage return feat...

Страница 31: ...0152 Multiple identifier and result parts notifications Command 04 Data length up to 25 characters Example 04 VIN1234567 04 VIN1234567 As mentioned above a bar code is assumed to be a VIN number if t...

Страница 32: ...p to 25 digits Example 07 GU49CN53 07 GU49CN53 Identifier part 4 This command sets the Identifier part 4 reported by the ASG NW2500 in ACOP result messages and the MID 0152 multiple identifier and res...

Страница 33: ...to perform a remote halt Command 42 Data length none Example 42 42 Remote Halt via barcode activates an input as described in the Mapping of ACOP commands to X PAQTM inputs section With a properly pro...

Страница 34: ...several fields of information about each tightening on a separate line An example result is shown below in Line Format VIN VIN Identifier 1 Identifier 2 Identifier 3 Time YYYY MM DD HH MM SS Task Par...

Страница 35: ...folder of the drive If you received the firmware update already on a USB drive proceed to step 2 2 Turn on power to the unit and let it go through the startup process 3 Insert the USB drive into the c...

Страница 36: ...make room for new entries Network Log The network log file will be saved to the USB drive as net g4n where is the last four digits of the ASG NW2500 serial number This file contains the network log d...

Страница 37: ...tion of use rather than for resale for a period of one 1 year from the first in service date or one million 1 000 000 cycles Within the warranty period ASG Precision Fastening will replace or repair t...