Backboard

Power Supply Signal Time Scale

© 2017 Jergens, Inc.  All Rights Reserved   |   Revision Date: 2/23/2017

Output/Input Signal 
Terminal: 

controls 

start and stop of 
electric driver, and 
clutch output signal  

Power Cord Socket

Fuse Jack, 2A/110V or 1A/230V

Input Voltage 
Selection Switch: 

providing choice of 
110V/230V

T1

Turn on the power and start the power supply at least 2 seconds after the power is off (Robotic Operation)

T2

Input the signal to start the electric driver at least 2 seconds after the power supply is started (Robotic Operation)

T3

Indicating the start signal of the electric driver, which shall exceed 0.5 second

T4

Indicating the run time of the electric driver, which varies with the locking time

T5

The clutch signal of the electric driver

T6

Signal output by the backboard (Finish) of the power supply when the clutch operates, lasting for a period from the time when the clutch activates until the 
input of Stop signal

T7

Indicating the stop signal (required to be longer than 0.5 second), which is explained as follows:
• 

If the electric driver is running, input of this signal may stop the electric driver before a clutch signal is seen

• 

If the clutch activates, the signal may open Finish output (Open)

• 

When the Start signal exists, Stop signal will not be accepted. A minimum interval of 0.5 second is required between the two signals

T8

The interval between the stop signal and start signal should be longer than 0.5 second