ASG, Division of Jergens, Inc.
15700
S. Waterloo Road | Cleveland, OH 44110-3898 | Phone: (888) 486-6163 | Fax: (216) 481-4519 | Email: [email protected] | Web: www.asg-jergens.com
HIOS CL, SS, and A Series
Operational Manual
Torque Adjustment Procedure
• Use the torque adjustment nut to select the desired output
setting. Note that this setting should be taken as an approximate
value. Adjust the setting by loosening the adjustment nut stopper
and adjusting the torque adjustment nut. When the setting
has been made, re-tighten the torque adjustment nut stopper
securely. Repeat this process to determined the appropriate
tightness. Use a torque tester to verify.
• The torque adjusting nut of CL-6000, CL-6500, CL-7000 may
be locked after the position is determined. Holding the Torque
Adjusting Nut, rotate only the metal band around it until a
tapped hole is uncovered. Install a M3 x 3 set screw there and
tighten it. Return band to original position.
• The torque adjusting nuts of the CL-2000, CL-3000, CL-4000 can
be locked by aligning the red mark on the outer casing with any
one of two vertical grooves (or three grooves for the standard-
type screwdriver) of the bolt located nearest the torque adjusting
scale. To change the position, lift and turn the nut outer casing.
• The CL-2000 (SS-2000) Electric Screwdriver have ‘Double nut
system’ (Nut fixing ring and Torque adjusting nut) to avoid
loosening from shock or vibration to the driver. To adjust,
hold the nut fixing ring at desired scale then move the torque
adjusting nut to secure.
• Disconnect the cord to shut off power when handling the Quick
Change Collet for replacing bit to avoid danger from surprise
starting.
Repairs
Contact ASG with any questions or concerns at +1-888-486-6163 or
[email protected]
How to Replace Carbon Brushes
1. To maintain performance, it is recommended to
replace the pair of carbon brushes when they
wear to approximately half their length.
2. Carbon brush caps have a slot. Unscrew them
with a flat tip driver to open them. Be careful
not to allow the carbon brush inside to jump out
as it is kept there under spring pressure.
3. With the mini-type screwdriver, one of the
carbon brush covers is located under the switch
lever, therefore, the switch lever must be
removed before reaching it.
4. Replace the worn carbon brushes with new pair.
Note that the end surface of the carbon piece
is slightly concave. The carbon piece should be
placed in the correct direction when inserting
into the holder so that the curved end of the
brush makes a smooth contact with the surface
of the commutator. Screw the cap tightly.
Concave
Power Supplies
CLT-45: Connects to one CL, SS or A-series driver (except CL-7000,
SS-7000, A-6500, CL-9000).
CLT-60: Connects to one CL, SS or A-series driver (except CL-9000).
Model Number
CLT-45
CLT-60
Size (mm)
71.5x146x42.6
88x210x52
Weight (kg)
0.33
0.715
Input
AC100-240V ±5% | 47/63 Hz
Output Voltage
LOW/HI
AC Cord Length
1.8m