ASG DTT Series Скачать руководство пользователя страница 6

 

The LCD display will show the torque that the driver or wrench is set at. Note the 
reading or write It down. To enter it into the DTT memory press the “MEM / ENTER” 
button. If you are testing several tools note the memory numbers of the readings for 
the various tools. This number is in the bottom right hand corner of the LCD. The unit 
can save up to 200 readings. After that no further readings can be entered until the 
memory is cleared. See the operating manual for instructions on downloading and 
clearing the readings in the memory. 

 

If the torque is not correct, adjust the tool. Repeat the test. When the reading is 
proper perform the test several times to be sure the readings are stable. The proper 
reading may be an average of several readings. 

 

7) 

PROCEDURE FOR POWER SCREWDRIVERS 

 

Put the driver adapter into the unit’s female 3/8” square socket. This is also called a 
joint simulator. It allows the power tool to reach its working speed before tightening 
up and causing the clutch to operate 

 

Run the tool in reverse to make sure the adapter is unwound. Take care not to 
disassemble the driver adapter. 

 

Make sure the unit is in PEAK mode. If it is not use the “MODE” button to select Peak 
mode. Press the “RESET / ESC” button to be sure the display is at 0Run the tool 
forward until it shuts off. The reading on the display will be the torque setting of the 
tool’s clutch. Note the reading or write it down. To enter it into the units memory 
press the “MEM / ENTER” button. If you are testing several tools note the memory 
numbers of the readings for the various tools. This number is in the bottom right hand 
corner of the LCD. The unit can save up to 200 readings. After that no further readings 
can be entered until the memory is cleared. See the operating manual for instructions 
on downloading and clearing the readings in the memory. 

 

If the torque is not correct, adjust the clutch. Repeat the test. When the reading is 
proper perform the test several times to be sure the readings are stable. The proper 
reading may be an average of several readings. ALLWAYS UNWIND THE DRIVER 
ADAPTOR AFTER EACH TEST. DO NOT LEAVE THE SPRING UNDER TENSION 
WHILE NOT IN USE 

 

8) 

INSTRUCTIONS FOR USING THE DRIVER ADAPTER 

 

Use an adapter that has a higher capacity than the tool you are using. Before using 
the adapter, make sure the thread is unwound but engaged. Turn the shaft by hand to 
make sure the thread is turning smoothly and the bearing is also turning smoothly. 

     

 

 

Refer to the pictures below to identify the various driver adapters and springs to 

 

determine the proper set up to obtain the correct match for measuring torque 

 
 
 
 
 

 
 
 
 
 
 
 
 

 

 
 

 

 
 
 

Содержание DTT Series

Страница 1: ...OPERATING MANUAL SEPTEMBER 2013 DTT Version 4H ASG Div Jergens Inc 15700 S Waterloo Rd Cleveland Ohio 44110 3898 Phone 216 486 6163 Fax 216 481 4519 E mail asginfo asg jergens com Web www asg jergens...

Страница 2: ...ion 9 Printing and Data output 9 Service and Warranty 9 System Overview 10 Torque Conversion Factors 11 NOTE The Programming and Calibration Manual contains the password to enter the calibration menu...

Страница 3: ...r after installation 2 STANDARD EQUIPMENT All DTT meters are supplied with the following standard items Plastic carrying case RS 232 Communication cable or USB to Serial bridge cable CD containing ASG...

Страница 4: ...nit will default to the PEAK setting when turned on Use the MODE button to change to the TRACK or FIRST PEAK setting if desired This function may not work with the battery charger connected to the uni...

Страница 5: ...on you will only change the mode Button 4 MEM Memory In normal operation pressing the MEM button enters the torque reading into the DTT memory 5 OVERLOAD CAPACITY CAUTION Do not deliberately exceed th...

Страница 6: ...e RESET ESC button to be sure the display is at 0Run the tool forward until it shuts off The reading on the display will be the torque setting of the tool s clutch Note the reading or write it down To...

Страница 7: ...ecome unscrewed or disassembled during use Refer to the drawing below for proper assembly rather then relying on the creativity of individuals All ASG DTT driver adapters using springs regardless of t...

Страница 8: ...612 1 3 to 5 lbf in 66616 Replacement Black Spring for 66612 4 3 to 26 lbf in 66618 Replacement Driver Adapter hex drive 25 to 90 lbf in New one piece unit replaces earlier 2 piece unit 66634 Replacem...

Страница 9: ...t printing to a serial printer Either the PS2 to DB9 or the USB to Serial bridge cable can be used To print see the instructions in the Programming and Calibration manual in the AUTO PRINT section of...

Страница 10: ...hargeable Battery charger 110 120 VAC 60 Hz 12W input 12 VDC 500mA output Optional 220 240 VAC input available ADC 24 bits CPU 8 bits Communication RS232C Key button 4 Buttons Unit of measure 9 User S...

Страница 11: ...1 152 0 0115 113 0 11 3 0 113 1 lbf ft 192 0 12 0 1 0 13826 0 13 83 0 138 1356 0 135 6 1 356 1 gf cm 0 014 0 0009 0 00007 1 0 0 001 0 0001 0 098 0 01 0 0001 1 kgf cm 13 890 0 868 0 072 1000 0 1 0 0 0...

Страница 12: ...12 Division of Jergens Inc 15700 S Waterloo Road Cleveland Ohio 44110 3898 Toll Free 888 486 6163 Fax 216 481 4519 Email asginfo asg jergens com www asg jergens com...