Flight Manual
Flight Manual
Issue:
15.09.2017 PA
Appr.
Revision: TN 12 30.10.21 PA
4.10a
Ground run
WARNING
Perform ground run with rigged aircraft only!
CAUTION
The freestream during flight is necessary for the proper air cooling
of the propulsion like it is the case during normal operation as sus-
tainer. The motor overheats after about 10 minutes ground run with
a power setting of 100% and 20°C (68°F) outside air temperature.
The operation limitations of this flight manual chapter 2.4 have to
be met anyway.
CHECKLIST: Extending propeller and starting motor
- Battery emergency stop: OFF (= not pushed; release by turning)
- Power-plant main switch: ON (power-plant instrument on)
- Power lever:
EXTEND (until the noticeable stop
position)
- Observe correct extension process in the mirror, blue message
„PRESS Starter Button“ appears, propeller holds in vertical position
- Check power-plant instrument for warnings
- Propeller area:
CLEAR
- Wheel brake:
ENGAGE (fully extended airbrakes)
- Starter:
ENGAGE
- Adjust power-setting at the power lever as desired
CHECKLIST: Stopping motor and retracting propelle
- Power lever:
0% (until the noticeable stop position)
- Observe braking and vertical alignment
- Power lever:
RETRACT (bottommost)
- Observe correct retraction process in the mirror
- Power-plant main switch: OFF