Aseptico ADU-04ST Скачать руководство пользователя страница 3

3.

Your new Aseptico ADU-04ST Manual Dental Control System 

is one of the finest handpiece control systems available to the 

professional. Offering manual activation and a remote stand, 

the ADU-04ST model provides an economic control system for 

dental operators, hygienist’s room or satellite office.

Congratulations!

This system is engineered to provide many years of reliable 

service. Please read the instructions provided in this manual 

to receive the best and longest service from your Aseptico 

equipment.

Separate manuals may be provided to cover the operation and 

maintenance of handpieces or other accessories for your unit. 

Handpieces are purchased separately.

PACKAGE CONTENTS

• 

ADU-04 Pneumatic Control Unit

• 

TA-90D 3-Way Air/Water Syringe with Tips

• 

AA-42 Foot Control and Tubing

• 

Highspeed Handpiece Control

• 

Lowspeed Handpiece Control

• 

NWS-8 Self Contained Clean Water System

• 

AA-61 Water Connector for scalers

• 

25-Foot Extension Line

OPTIONS

• 

AA-21ST High Volume Evacuator - HVE

• 

AA-25ST Saliva Ejector System

• 

Fiber Optics Kit for fiber optics handpieces

SETTING UP THE UNIT:

Figure 1 - Case Contents

*High Volume Evacuator (opt.)

AA-61 Water Connector 

for Scaler

Water Supply Bottle
AA-25ST Saliva Ejector 

Assembly (opt.)

25 Foot Extension Line

Syringe and Tubing

AA-21ST HVE* Collection 

Container (opt.)
AA-21ST HVE Hose 

Assembly (opt.)

Handpiece Connection

Folded Tripod

Handpiece 

Connection

Foot Control 

and Tubing

Accessory Tray

Bottle Brush

1.  The ADU-04ST comes factory-mounted on a tripod stand.
2.  Remove the system from the carrying case (Fig. 1), fully 

extend tripod legs, and stand the system up (Fig. 2).

3.  Unit height is adjusted by loosening the adjustment handle 

on tripod, raise or lower system, then tighten adjustment 

handle.

AA-21ST HVE 

(Optional)

AA-25ST Saliva 

Ejector (Optional)

Tripod Height 

Adjustment Handle

Carrying Case

Fully Extend 

Tripod Legs

Figure 2 - ADU-04ST Setup

Содержание ADU-04ST

Страница 1: ...ADU 04ST Manual Dental Control System OPERATION and MAINTENANCE INSTRUCTION MANUAL HVE and Saliva Ejector options...

Страница 2: ...n 6 Figure 5 Air Water Syringe 6 Cleaning 6 Warranty 7 SPECIFICATIONS Case Size 11 in x 11 in x 40 in Case Weight 18 lbs Power Source 80 100 PSI Compressed Air To prevent injury to people and damage t...

Страница 3: ...trol NWS 8 Self Contained Clean Water System AA 61 Water Connector for scalers 25 Foot Extension Line OPTIONS AA 21ST High Volume Evacuator HVE AA 25ST Saliva Ejector System Fiber Optics Kit for fiber...

Страница 4: ...ttach saliva ejector hose to the quick connect located on top of waste container and then place ejector valve into the holder located on left side of unit To remove waste container assembly push in on...

Страница 5: ...ir Water Syringe and high speed handpiece Saliva Ejector On Off Toggle Optional Turns vacuum On Off to the saliva ejector valve AA 21ST High Volume Evacuator Optional Provides vacuum flow to the High...

Страница 6: ...ted syringe tip 2 Remove all visible signs of contamination before autoclaving 3 Autoclave tip at 132 C 270 F for ten minutes 4 Sterilize between each patient use NOTE Since only the tips can be autoc...

Страница 7: ...s to notify Aseptico s Customer Service department promptly Customer Service will provide Return Material Authorization RMA instructions usually directing that the product be returned for service ship...

Страница 8: ...8 P O Box 1548 Woodinville WA 98072 8333 216th Street SE Woodinville WA 98072 425 487 3157 800 426 5913 www aseptico com info aseptico com PRINTED IN THE U S A P N 420261 Rev O ECO 15498 04 2022...

Отзывы: