7  PROGRAMMABLE PARAMETERS TABLE

Here below is a description of all the parameters available on the instrument.  Some of them may not be present because 
depend on the model/type of instrument.

Parameter

Description

Range

Default

Note

1

 

S.L1

Min. value for Set Point 1 (

SP1

)

-99.9 ÷ S.H1

-50.0

2

 

S.H1

Max. value for Set Point 1 (

SP1

)

S.L1 ÷ 999

99.9

3

 

S.L2

Min. value for Set Point 2 (

SP2

)

-99.9 ÷ S.H2

-50.0

4

 

S.H2

Max. value for Set Point 2 (

SP2

)

S.L2 ÷ 999

99.9

5

 

S.Sc

Set Point connection

in 

SP1 and SP2 independent;

2r 

SP2 relative to SP1;

d1 

SP1 never less than SP2 and SP2 never higher than SP1;

d2 

SP2 never less than SP1 and SP1 never higher than SP2.

in

6

 

SP1

Set Point 1 (

SP1

)

S.L1 ÷ S.H1

0.0

7

 

SP2

Set Point 2 (

SP2

)

S.L2 ÷ S.H2

0.0

8

 

i.uP

Unit and resolution of the measure-

ment (decimal point)

C0 

°C resolution 1°;

F0 

°F resolution 1°;

C1 

°C resolution 0.1°;

F1 

°F resolution 0.1°.

C1

9

 

i.Ft

Measurement filter

oF/0.1 ÷ 20.0 s

2.0

10

 

i.C1

Pr1 Probe Calibration

-30.0 ÷ 30.0°C/°F

0.0

11

 

i.C2

Pr2 Probe Calibration

-30.0 ÷ 30.0°C/°F

0.0

12

 

i.C3

Pr3 Probe Calibration

-30.0 ÷ 30.0°C/°F

0.0

13

 

i.P2

Pr2 Input usage

oF 

Not used;

r2 

Process value for r2 controller (loop);

Au 

Auxilary, enabled for the alarms display only;

dG 

Digital input.

oF

14

 

i.P3

Pr3 Input usage

oF

15

 

i.Fi

Digital input function and logic

No function;

External alarm;

External alarm and control outputs disable;

Switch on/off (Stand-by);

Auxiliary output command;

Door open with fan stop;

Door open without fan stop;.

0

16

 

i.ti

Delay in acquiring digital input

oF/0.01 ÷ 9.59 (min.s) ÷  99.5 (min.s.x10)

oF

17

 

i.dS

Variable normally shown on display

oF 

Display off;

P1 

Pr1

 measurement;

P2 

Pr2

 measurement;

P3 

Pr3

 measurement;

S1 

Set Point 1;

S2 

Set Point 2;

1.2 Alternated 

Pr1

 and 

Pr2 

probes measurement;

1.3 Alternated 

Pr1

Pr2

 and 

Pr3 

probes measurement.

P1

18

 

i.td

Time each variable remains dis-

played

1 ÷ 30 s

5

19

 

r.Fc

Controller functioning mode

nr

 

Neutral zone: 

r1

 Cools with 

SP1

 and 

Pr1

 

r2

 Heats with 

SP1

 and 

Pr1

;

CC

  Cool - Cool: 

r1

 Cools with 

SP1

 

r2

 Cools with 

SP2

;

HH

  Heat - Heat: 

r1

 Heats with 

SP1

 

r2

 Heats with 

SP2

;

HC

  Heat - Cool: 

r1

 Heats with 

SP1

 

r2

 Cools with 

SP2

;

CH

  Cool - Heat: 

r1

 Cools with 

SP1

 

r2

 Heats with 

SP2

.

nr

20

 

r.d1

Differential (histeresys) controller 

r1

0.0 ÷ 30.0 °C/°F

1.0

21

 

r.d2

Differential (histeresys) controller 

r2

0.0 ÷ 30.0 °C/°F

1.0

22

 

r.1n

Time 

r1 

activation for probe failure

oF/0.01 ÷ 9.59 (min.s) ÷  99.5 (min.s x 10)

oF

23

 

r.1F

Time 

r1

 deactivation for probe failure oF/0.01 ÷ 9.59 (min.s) ÷  99.5 (min.s x 10)

oF

24

 

r.2n

Time 

r2 

activation for probe failure

oF/0.01 ÷ 9.59 (min.s) ÷  99.5 (min.s x 10)

oF

25

 

r.2F

Time 

r2

 deactivation for probe failure oF/0.01 ÷ 9.59 (min.s) ÷  99.5 (min.s x 10)

oF

26

 

r.FF

Fans output operating mode

Fans not connected to the controllers;

Fans connected to controller 

r1

;

Fans connected to controller 

r2

;

Fans connected to both controller.

0

27

 

P.11

Output 

r1

 activation delay

oF/0.01 ÷ 9.59 (min.s) ÷  99.5 (min.s x 10)

oF

28

 

P.12

Delay after output 

r1

 switch OFF

oF/0.01 ÷ 9.59 (min.s) ÷  99.5 (min.s x 10)

oF

Содержание Y39W

Страница 1: ...studied in particular to manage refrigeration units display cases etc typically in tended for the storage and distribution of wines and or drinks in domestic or commercial uses The instrument is equi...

Страница 2: ...both loops programmed for heating action but with parameter t Ld 2 this LED shows the r1 controller status while the status of controller r2 is shown by Aux LED 8 LED Indicates Defrost in progress ON...

Страница 3: ...to 0 now using the keys insert the programmed password number and press the key again If the password is correct the instrument displays the code of the first parameter and it will be possible to pro...

Страница 4: ...use of the instrument for applications not expressly permitted by the above mentioned rule must adopt all the necessary protective measures The instrument MUST NOT BE USED in dangerous flamma ble or...

Страница 5: ...vices ex fuses proportionate to the circulat ing currents It is strongly recommended that cables with proper insula tion according to the working voltages and temperatures are to be used Furthermore t...

Страница 6: ...ables that can be displayed are Pr1 Probe Pr1 measurement Pr2 Probe Pr2 measurement on oF if set as digital input Pr3 Probe Pr3 measurement on oF if set as digital input The system automatically exits...

Страница 7: ...the following functions oF Buzzer always disabled 1 The Buzzer sounds when an alarm is active 2 The Buzzer sounds when a key pressed does not signal alarms 3 The Buzzer sounds when a key pressed and...

Страница 8: ...nfigured for r1 and r2 operation the LEDs still indicate the controllers status If both controllers are configured for the same action r Fc CC HH the or LEDs indicate the activation of at least one of...

Страница 9: ...frost the control outputs ot and the Fanscon tinue operating while df output is enabled 5 8 1 Automatic Defrosts Start The automatic control of defrost occours by Interval times For continuous compres...

Страница 10: ...s of parameters A y2 and A y2 are 1 Absolute Alarms referred to Pr1 probe 2 Alarms Relative to SP1 referred to pr1 probe 3 Absolute Alarms referred to r2 probe 4 Alarms Relative to SP2 referred to r2...

Страница 11: ...e key for at least 5 s it is possible to enable disable a defrost cycle 3 Pressing the key for at least 1 s it is possible to switch the instrument from the ON status to Stand by status and vice versa...

Страница 12: ...itch on off Stand by 4 Auxiliary output command 5 Door open with fan stop 6 Door open without fan stop 0 16 i ti Delay in acquiring digital input oF 0 01 9 59 min s 99 5 min s x10 oF 17 i dS Variable...

Страница 13: ...H2 e A L2 oF 0 01 9 59 min s 99 5 min s x 10 oF 46 A PA Temperature Alarms delay at power ON oF 01 9 59 h min 99 5 h min x 10 2 00 47 A dA Temperature Alarms delay after defrost oF 0 01 9 59 h min 99...

Страница 14: ...with a detailed description of the faults found without any fees or charge for Ascon Tecnologic except in the event of alterna tive agreements 10 TECHNICAL DATA 10 1 Electrical Data Power supply 12 VA...

Страница 15: ...rective 2006 95 CE EN 60730 1 EN 60730 2 9 Regulation 37 2005 CE EN13485 air S A 2 50 C 90 C with probe NTC 103AT11 11 HOW TO ORDER Model Y39W Instrument with mechanical keyboard Y39SW Instrument with...

Страница 16: ...Ascon Tecnologic Y39W Line Operating Instructions Pag 16...

Отзывы: