Ascon Tecnologic - T82N- OPERATING INSTRUCTIONS - PAG. 6

F.o2t

 = 

6 - Activation at 

S.t1

 count end with 

S.t3

 delay for 

S.t2 

time

Out2

 thus configured is activated, as for 

F.o2t

 = 

5

, when 

S.t1

 count has elapsed for the time 

S.t2

 but with a settable 

delay 

S.t3

.  This function is intended to be used with  

F.o1t 

2

 only.

Reset

Start

f.o1t

 = 

2

,

 

f.o2t

 = 

6

OUT1

off

S.t1

OUT2

off

off

S.t3 S.t2

F.o2t

 = 

7 - Activation at the end of 

S.t1

 count with delay 

S.t2

Out2

 thus configured is activated when 

S.t1

 count has 

elapsed with a settable delay 

S.t2

.  This function is in-

tended to be used with 

F.o1t 

2

 only and can be used to 

create a 

star-delta starter

 where the time 

S.t1

 is the 

Star 

operating time

 while 

S.t2

 is 

the Star-Delta transfer time

.

Reset

Start

f.o1t

 = 

2

,

 

f.o2t

 = 

7

OUT1

off

OUT2

off

off

S.t1

S.t2

F.o2t

 = 

8 - Counting operation negated with respect to Out1

Out2

 output thus configured is activated, during the count, 

with the opposite logic to 

Out1

.  This function is intended to 

be used with 

F.o1t

 = 

3

 or 

4

 only (oscillator mode functioning) 

in order to obtain the alternated operation of the two outputs.

Reset

OUT1

Start

off

S.t1

S.t1

S.t2

S.t2

S.t1

OUT2

off

off

off

f.o1t

 = 

3

,

 

f.o2t

 = 

8

off

off

off

Reset

OUT1

Start

S.t1

S.t1

S.t1

S.t2

S.t2

OUT2

off

off

off

off

f.o1t

 = 

4

,

 

f.o2t

 = 

8

off

off

off

F.o2t

 = 

9 - Counting operation negated with respect to Out1 

but with an 

S.t3

 dead time

As in 

F.o2t

 = 

8

, while counting 

Out2

 output is activated 

with the opposite logic to 

Out1

, but with an 

S.t3

 interme-

diate settable dead time.
Also in this case, this function is intended to be used with 

F.o1t

 = 

3

 or 

4

 only (oscillator mode functioning) in order 

to obtain the alternated operation of the two outputs, but 
with a dead time between the activations.

Reset

OUT1

Start

off

S.t1 S.t3

OUT2

off

off

f.o1t

 = 

3

,

 

f.o2t

 = 

9

off

off

off

S.t2 S.t3

S.t1 S.t3

S.t1

S.t3

S.t2 S.t3

Reset

OUT1

Start

off

S.t1 S.t3

OUT2

off

off

f.o1t

 = 

4

,

 

f.o2t

 = 

9

off

off

off

S.t2 S.t3

S.t1 S.t3

S.t1

S.t3

S.t2 S.t3

F.o2t

 = 

10 - Symmetrical denied operation with respect 

to Out1 with dead time 

S.t3

As in 

F.o2t

 = 

9

 mode, while counting 

Out2

 output is 

activated with the opposite logic to 

Out1

, with an 

S.t3

 

intermediate settable dead time, but with the same active 
time of 

S.t1

.

Also in this case, this function is intended to be used with 

F.o1t

 = 

3

 or 

4

 only (oscillator mode functioning) in order 

to obtain the alternated operation of the two outputs with 
a dead time between the activations, but with the pos-
sibility to establish the total duration of the cycle through 
the time 

S.t2

 (for example for a washing, cleaning, pol-

ishing or similar treatment cycle).

Note: 

The total time is established to be 

S.t2

 as it has an 

independent time scale with respect to 

S.t1

 and 

S.t3

 

which have the same time scale.  For these applica-
tions 

S.t2

 probably needs to be set 

in hours

 while 

S.t1 

and 

S.t3

 could be 

in minutes

.

Reset

OUT1

Start

off

S.t1 S.t3

OUT2

off

f.o1t

 = 

3

,

 

f.o2t

 = 

10

off

S.t3

S.t1

S.t1

S.t1

S.t3

S.t3 S.t1

S.t1

S.t2

S.t2

off

Reset

OUT1

Start

off

S.t1 S.t3

OUT2

off

f.o1t

 = 

4

,

 

f.o2t

 = 

10

off

S.t3

S.t1

S.t1

S.t1

S.t3

S.t3 S.t1

S.t1

S.t2

S.t2

off

off

off

off

Содержание T82N

Страница 1: ...FC communication interface embedded in the instrument The instrument offers the possibility to program up to 3 delay times or Set Times 6 operating modes for Out1 output 10 operating modes for Out2 ou...

Страница 2: ...ent for applications not expressly permitted by the above mentioned rule must adopt all the necessary protective measures The instrument must not be used in dangerous environ ments flammable or explos...

Страница 3: ...NC NO C NC C NO Voltage inputs 24 240 VAC VDC 24 240 VAC VDC 5 OPERATING MODE 5 1 Counting commands operation Counting is enabled and disabled using the the digital inputs CNT and RST The operating mo...

Страница 4: ...Reset and a new Start signal Reset OUT1 Start off f o1t 2 S t1 F o1t 3 Asymmetrical oscillator with start ON This operating mode requires the setting of both S t1 and S t2 Set times Received the Star...

Страница 5: ...t f o1t 3 f o2t 3 OUT1 off off S t1 S t1 S t2 OUT2 off off S t3 S t3 Reset Start f o1t 4 f o2t 3 OUT1 off S t2 S t1 OUT2 off off off off off S t3 S t2 S t1 S t3 Reset Start f o1t 5 f o2t 3 OUT1 S t2 S...

Страница 6: ...Out1 but with an S t3 interme diate settable dead time Also in this case this function is intended to be used with F o1t 3 or 4 only oscillator mode functioning in order to obtain the alternated opera...

Страница 7: ...TOP 5 Bistable RESET START STOP 6 Bistable START STOP RESET 4 8 F o1t OUT1 output operating mode 1 On delay 2 Feed through 3 Asymmetrical oscillator with start ON 4 Asymmetrical oscillator with start...

Страница 8: ...tput Electrical life 100000 operations Overvoltage category II Protection class Class II Insulation Reinforced insulation between low voltage parts power supply and relay outputs and front panel Main...

Отзывы: